Page 11

This page is intentionally left blank.

x

Page 12

DATALOGIC

DS6100

1 GENERAL FEATURES 1.1 INTRODUCTION The DS6100 scanner is a barcode reader complete with decoder designed to provide an inexpensive solution in omnidirectional reading applications by combining the following advanced technologies with Datalogic’s solid experience in the material handling sector.

ACR™ Advanced Code Reconstruction Technology allows the reading of low aspect ratio labels placed anywhere on a parcel and enhances the readability of poorly printed or damaged codes.

CD SQUARE™ CD SQUARE™ provides useful information on label position and object shape elaborated during the barcode reading phase. This innovative technology identifies the area in which the code is located and measures the code distance from the scanner.

PACKTRACK™ PackTrack™ is a Datalogic patented parcel tracking system which improves the reading features in omnidirectional stations. In particular, PackTrack™ manages 6-sided reading systems when it is impossible to detect the real position of the code on the parcel, thus overcoming the need for external accessories essential in traditional tracking systems.

Flexibility The high frequency laser diode modulation system guarantees complete immunity to ambient light and allows installation of the DS6100 in any working area.

General Features - 1.1

Page 13

DS6100

DATALOGIC

DS6100 is provided with an Adjustable Focus System which enables the user to freely select the most suitable reading field for his application. Focus length can be very easily adjusted by choosing among six different positions of the optical system. DS6100 is easily configurable by means of the user-friendly Windows based WinHost configuration program provided on a diskette. It is also possible to configure the scanner either through the built-in keypad or by sending ESC sequences from a Host computer.

1.2 DESCRIPTION Some of the main features of DS6100 are listed below: • scanning speed 800 scans/sec. for standard models; higher speeds available on request.

•

2 serial communication interfaces.

• reads all popular codes.

• supply voltage from 10 to 30 Vdc.

• electrical connection through connectors or through a junction box.

• test mode to verify the reading features and exact positioning of the scanner without the need for external tools.

• programmable in 5 different operating modes to suit the most various barcode reading system requirements.

• light source: solid state laser diode; the light emitted has a wave length of 650~680 nm. For laser safety precautions refer to the “Safety precautions” section at the beginning of this manual.

• low power consumption.

•

IP65 protection class of the enclosure; the reader is therefore suitable for industrial environments where high protection against harsh external conditions is required.

1.2 - General Features

Page 14

DATALOGIC

DS6100

1.2.1 Indicators The DS6100 has three LEDs and an LCD display on the front panel, one LED on the side panel and an internal beeper. The indicators have the following functions: EXT TRIG

(yellow) Indicates the external presence sensor is active. (Figure A, 9 ).

GOOD READ

(red)

Indicates a probable code is present in the reading zone. (Figure A, 8 ).

TX DATA

(green)

Indicates the main serial interface is operating correctly during data transmission. (Figure A, 7 ).

LASER ACTIVE

(green)

Indicates the laser beam for barcode reading is active. (Figure A, 2 ).

LCD

The LCD displays messages relative to the DS6100 configuration and to the code read after decoding. It is a 2 x 16 character display. (Figure A, 6 ).

1.3 AVAILABLE MODELS The DS6100 scanner is available in the following versions: DS6100 – 3000: standard resolution, connector, nd 2 generation ACR, sw selection of interfaces DS6100 – 3100: standard resolution, junction box, nd 2 generation ACR, sw selection of interfaces

General Features - 1.3

Page 15

DS6100

DATALOGIC

1.4 ACCESSORIES The following DS6100 accessories are available on request: PG110/50 PG220/50 GFC-50 GFC-05 US-1 XMF-05 XBOX-05 VOY-05 US-05 INT-26

Power block (110 Vac) Power block (220 Vac) 90° reading device oscillating mirror attachment installation support single cross mounting frame connection box single/double cross (for Junction Box models only) Voyager kit for XBOX-05 mounting brackets (10 pcs) 20 mA C.L. interface module

1.5 APPLICATIONS The DS6100 barcode reader was specifically designed for industrial applications and for all cases requiring high reading performance such as: • code reconstruction • reading of codes with a wide depth of field • reading of high resolution codes positioned at long distances from the reader • code reading on fast moving objects DS6100 is designed for both single-reader layouts and multi-reader layouts. For typical layouts see par. 2.8.

1.4 - General Features

Page 16

DATALOGIC

DS6100

2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS6100 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: 1) DS6100 reader 2) Installation Manual + barcode test chart 3) DS6100 configuration disk 4) Mounting screws Connector version 5) 3-pin female connector (power supply) 6) 6-pin male connector (inputs) 7) 19-pin male connector (outputs)

Junction Box version 8) JBOX

2 3 5

6

7

4

8 1

Figure 2.1 - DS6100 package contents

Installation - 2.1

Page 17

DS6100

!

DATALOGIC

2.2 OPENING THE SCANNER

DS6100 scanners can be completely configured through software using one of the three methods listed in the "Guide to Installation" at the beginning of this manual. The scanner therefore can be installed without the necessity of opening it to configure hardware switches. To determine if it is necessary to open the scanner for hardware configuration of your application, the default hardware settings are listed below: •

Multidrop address selection = address 0 (software configurable)

•

Inputs = NPN

To change the default settings, before installing the DS6100, refer to the procedures in the following paragraphs: • setting the multidrop address (hardware configuration) see par. 2.2.1 • select the input type see par. 2.2.2

WARNING Before unscrewing the connector or cable panel of the DS6100, make sure the power supply cable is disconnected to avoid shock or harm to the operator.

Refer to the following instructions and refer to Figure 2.2 when opening the reader: 1. The part of the device to be opened is the connector or cable panel on the side of the scanner. 2. Unscrew the four screws to open the scanner.

2.2 - Installation

Page 18

DATALOGIC

DS6100

3. Carefully remove the panel as shown in Figure 2.2. Pay attention not to stretch the cables between the panel and the scanner.

DS6100 CONNECTOR MODEL

DS6100 JUNCTION BOX MODEL

Figure 2.2 - Opening the DS6100

Installation - 2.3

Page 19

DS6100

!

DATALOGIC

2.2.1 Multidrop Address Selection

When using the RS485 half-duplex interface, the Multidrop address must be selected. The Multidrop Address can be selected either via software or through the DIP switch. Refer to the WinHost Help On Line for software selection. To set the Multidrop Address through the DIP switch proceed as follows: 1. Open the panel as described in par. 2.2. 2. Position the switches as desired, referring to Figure 2.3. Connector Panel

Junction Box Cable Panel

DS6100

DS6100

5 4 3 2 1 ON Dip Switch

Dip Switch

5 4 3 2 1 ON Figure 2.3 – DS6100 Multidrop Address Selection

2.4 - Installation

Page 20

DATALOGIC

DS6100

The following table shows the Multidrop address settings where: 1 = ON

5

4

Position 3 2

1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

0 = OFF

Address 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

5

4

Position 3 2

1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

Address 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Address 0 is the default which allows software configuration.

Installation - 2.5