The text of a manual · part 1 of 6
DS6100 Installation Manual, pages 1 to 10
Pages 1 to 10 of 59
The original document is the PDF (785 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-6100
Page 1
Mn OSSG1O0
Installation Manual
DATALOGIC] BE
Bar Code & More
Page 2
DS6100 INSTALLATION MANUAL
Page 3
We
DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product DS6100-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standards or other normative documents EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 50082-2, March 1995:
ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT
EN 60950, October 1996:
SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT
EN 60825, March 1993:
RADIATION
SAFETY OF LASER PRODUCTS, CLASSIFICATION, REQUIREMENTS AND USER’S GUIDE
EQUIPMENT
Following the provision of the Directive(s): 89/336 CEE AND SUCCESSIVE AMENDMENTS, 92/31 CEE; 93/68 CEE; 73/23 CEE
Ruggero Cacioppo Lippo di Calderara, 23.03.1998 Quality Assurance Supervisor
Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies. Datalogic reserves the right to make modifications and improvements without prior notification. © 1997, 1998, 1999 Datalogic S.p.A. 821000105 (Rev. E)
Page 4
CONTENTS GUIDE TO INSTALLATION ...............................................................v SAFETY PRECAUTIONS ................................................................viii Electrical Safety ................................................................................viii Laser Safety......................................................................................viii Standard Regulations .......................................................................viii 1 1.1 1.2 1.2.1 1.3 1.4 1.5
GENERAL FEATURES ...................................................................1.1 Introduction ......................................................................................1.1 Description.......................................................................................1.2 Indicators .........................................................................................1.3 Available Models..............................................................................1.3 Accessories .....................................................................................1.4 Applications .....................................................................................1.4
2 2.1 2.2 2.2.1 2.2.2 2.3 2.4 2.4.1 2.4.2 2.5 2.5.1 2.5.2
INSTALLATION ..............................................................................2.1 Package Contents ...........................................................................2.1 Opening The Scanner......................................................................2.2 Multidrop Address Selection ............................................................2.4 Input Selection .................................................................................2.6 Mechanical Installation ....................................................................2.7 Junction Box Installation ..................................................................2.9 Junction Box Mounting ....................................................................2.9 Junction Box Electrical Connections..............................................2.10 Electrical Connections for Connector Models................................2.13 Power Supply.................................................................................2.16 Main Serial Interface......................................................................2.16 RS232 Interface.............................................................................2.17 RS485 Full-Duplex Interface..........................................................2.18 RS485 Half-Duplex Interface.........................................................2.19 20 mA Current Loop (INT-26 Accessory Only) .............................2.21 Auxiliary Interface ..........................................................................2.22 Inputs .............................................................................................2.23 Outputs ..........................................................................................2.26 Positioning .....................................................................................2.27 Focus Adjustment..........................................................................2.29 Typical Layouts ..............................................................................2.30 Standard (Point-to-Point) ...............................................................2.30 Pass Through ................................................................................2.31
2.5.3 2.5.4 2.5.5 2.6 2.7 2.8 2.8.1 2.8.2 iii
Page 5
2.8.3 2.8.4 2.8.5 2.8.6
RS485 Master/Slave......................................................................2.31 Multiplexer .....................................................................................2.33 MUX24HS......................................................................................2.34 PackTrack Omnidirectional Reading .............................................2.34
3 3.1 3.1.1 3.2 3.3
READING FEATURES ....................................................................3.1 Advanced Code Reconstruction ......................................................3.1 Tilt Angle for Advanced Code Reconstruction.................................3.1 Performance ....................................................................................3.2 Reading Diagrams ...........................................................................3.2
4 4.1
MAINTENANCE ..............................................................................4.1 Cleaning...........................................................................................4.1
5
TECHNICAL FEATURES................................................................5.1 iv
Page 6
GUIDE TO INSTALLATION The following can be used as a checklist to verify all the necessary steps for complete installation of the DS6100 scanner. 1. Read all information in the section Safety Precautions at the beginning of this manual. 2. Correctly position and mount the scanner for barcode reading according to the information in paragraphs 2.2, 2.3, 2.6, 2.8 and 3.3. 3. Provide correct system cabling according to the signals necessary (see the applicable sub-paragraphs under 2.4 or 2.5). 4. Install the Configuration Disk and configure the software parameters from a host computer using one of the following methods: • WINHOST interface utility program. For more details refer to the section “DS6100 Configuration” in the WINHOST Help On Line. • Host Mode programming procedure by ESC sequences via the serial interface. For more details refer to the Word document hds6100.doc in the DS6100 directory. • Keyboard Mode through the keypad and the display. For more details refer to the Word document kds6100.doc in the DS6100 directory.
NOTE Fine tuning of the scanner position for barcode reading can be accomplished using the Test Mode as described in WINHOST.
The installation is now complete.
v
Page 7
DS6100 General View 1
2
3
9
8 7 4
6 5 1
Laser beam output window
6
LCD 2x16 characters
2
Laser active LED
7
Data transmission LED
3
Focus regulation cover
8
Code present LED
4
Safety label
9
Presence sensor LED
5
Keypad Figure A vi
Page 8
DS6100 General View
10
11
DS6100 Connector model
DS6100 JBOX model
13
12
14
15
17
16
15
10 Warning and device class labels
14 Input connector
11 Product label
15 Oscillating mirror connector
12 Output / Serial interface connector
16 Power supply switch
13 Power supply connector
17 Junction box cable Figure B vii
Page 9
SAFETY PRECAUTIONS ELECTRICAL SAFETY This product conforms to the applicable requirements contained in the European Standard for electrical safety EN-60950 at the date of manufacture.
!
This symbol refers to operations that must be performed by qualified personnel only. Example: opening the device. This symbol refers to operations where there is danger of electrical shock. Before opening the device make sure the power cable is disconnected to avoid electric shock.
LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of the DS6100 scanner.
Standard Regulations This scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc. This product conforms to the applicable requirements of both IEC 825-1 and CDRH 21 CFR 1040 at the date of manufacture. The scanner is classified as a Class 2 laser product according to IEC 825-1 regulations and as a Class II laser product according to CDRH regulations. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed.
viii
Page 10
WARNING Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light. The laser light is visible to the human eye and is emitted from the window on the side of the reader (Figure A, 1 ). Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A, 4 , Figure B, 10 11 ): ,
DATALOGIC S.P.A. Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY Manufactured Volt Model No.
Amp.
Serial No. This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture.
Warning and device class labels
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. The laser diode used in this device is classified as a Class 3B laser product according to IEC 825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the following label is reproduced here: LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION EMITTED WAVE LENGTH TO IEC 825-1 (1993)
10 mW 650~680 nm
Laser diode class label
Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (10 mW at 650~680 nm). ix