The text of a manual · part 3 of 6
DS4600 Installation Manual, pages 19 to 27
Pages 19 to 27 of 53
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4600
Page 19
INSTALLATION
2.3
2
JUNCTION BOX INSTALLATION
DS4600
The junction box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to the 25-pin connector models. Figure 3 shows the basic layout of DS4600 using the junction box.
Figure 3 - Scanner using junction box
For junction box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through 6 glands in the side of the junction box and the individual wires connect to spring clamp terminal blocks inside which provide access to all scanner signals.
2.3.1
Junction Box Mounting
The diagram below shows the dimensions of the junction box and its relative mounting holes.
56 2.21
60 2.36
29.5 1.16 60 2.36
Ø 4.5 N° 2 Ø 0.18 N° 2
83 3.27
122 4.8 109.5 4.31
GLANDS PG7 N°6 mm inch
Figure 4 - Junction box dimensions
7
Page 20
DS4600
2
The junction box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel. 2) Align the junction box and insert the two self-threading screws with their washers and screw them into the panel until tight (see Figure 5).
Figure 5 - Junction box mounting
8
Page 21
INSTALLATION
2.3.2
2
Junction Box Electrical Connections
The connection and wiring procedure for the junction box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: •
Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm.
•
Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 6).
•
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
Figure 6 - System cable connections to the junction box
The wiring used can be solid or stranded but must meet the following specifications. Positions 1-4:
24 - 16 AWG
0.2 - 1.5 mm²
Positions 5-39:
26 - 20 AWG
0.14 - 0.5 mm²
The junction box pinouts are indicated in the following table:
9
Page 22
DS4600
2 18
Junction Box pinout for DS4600 Pin
Name
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 27 28 34 35 36 37 38 39
VS GND VS GND CHASSIS VS VS EXT TRIG+ EXT TRIGGND GND VS VS IN1+ IN1GND GND OUT1+ OUT1OUT2+ OUT2IN2+ IN2Reserved GND GND TXAUX SGND Aux GND RXAUX Reserved
CAUTION
10
J1
1
39
5
17
Figure 7 - Junction box connector and pinout
To allow connection of an NEC Class 2 Power Unit, use a correct female plug adapter. Junction Box NEC Class 2 Power supply
Female Plug System cables Figure 8 - NEC Class 2 Power unit connections
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Page 23
INSTALLATION
Pin 24*, 29 25*, 30 26*, 31 32 33
*
2 RS232 TX232 RTS232 SGND Main RX232 CTS232
RS485 full-duplex TX485+ TX485SGND Main RX485+ RX485-
RS485 half-duplex RTX485+ RTX485SGND Main
20 mA CL (INT-24 Only) CLOUTSGND Main CLIN-
The signals on pins 24, 25 and 26 are repeated on pins 29, 30 and 31 to facilitate network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.
4) After wiring the junction box and while the scanner is unplugged from the power supply, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 9.
Rubber seal
J1
Scanner cable
Figure 9 - Scanner cable connections to the junction box
5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing. The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the junction box, simply reverse the procedure in step 4.
11
Page 24
DS4600
2
2.4
ELECTRICAL CONNECTIONS FOR 25-PIN MODELS
25-pin connector models (see paragraph 1.3) are equipped with a cable terminated by a 25-pin D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Figure 10 - 25-pin D-sub connector
25-pin D-sub connector pinout Pin
Name
Function
13 25 1 9 18 19 6 10 8 22 11 12 14 15 20 21 23 24 16 17
VS GND CHASSIS VS EXT TRIG+ EXT TRIGIN1 + IN1 OUT1 + OUT1 OUT2 + OUT2 IN2 + IN2 RXAUX TXAUX SGND Aux GND Reserved Reserved
Power supply input voltage + Power supply input voltage Chassis Ground Presence sensor supply voltage + External Trigger + External Trigger Input + Input Output + Output Output + Output Input + Input Auxiliary RS232 input Auxiliary RS232 output Signal Ground Auxiliary interface Power supply voltage -
RS232 2 3 4 5 7
12
TX232 Main interface RX232 (see par. 2.4.2) RTS232 CTS232 SGND Main
RS485 full-duplex TX485+ RX485+ TX485RX485SGND Main
RS485 half-duplex RTX485+
20 mA CL (INT-24 Only)
RTX485-
CLOUTCLINSGND Main
SGND Main
Page 25
INSTALLATION
2.4.1
2
Power Supply
Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host (Figure 11): USER INTERFACE
DS4600 13 VS
V+ (10 - 30 Vdc) 25 GND
GND CHASSIS
1
Earth Ground
CHASSIS
Figure 11 - Power supply connections or through the jack connector on the side of the 25-pin connector for connections to a UL Listed Direct Plug-in Power Unit (Figure 12). If the jack input is used to supply power to the DS4600, pin 13 is automatically disconnected; the supply voltage for the external trigger remains on pin 9. The plug connector is not supplied with the DS4600.
GND Jack
Plug
V+ (10 - 30 Vdc)
Figure 12 - Power supplied using the jack connector
The power must be between 10 and 30 Vdc only. There is a current peak of about 1A at 10 V during power on caused by the motor starting. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
13
Page 26
DS4600
2
2.4.2
Main Serial Interface
The signals relative to the following serial interface types are available on the input/output connector: RS232 RS485 FULL DUPLEX RS485 HALF DUPLEX An active 20-mA Current Loop interface is available if the optional INT-24 accessory is installed. This accessory interface replaces the RS232/RS485 selections. The main serial interface type and its relative parameters (baud rate, data bits, etc.) are selected via software either using the WinHost utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the WinHost Help On Line. Details regarding the connections and use of the main interface selection are given in the next paragraphs.
RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the configuration of the scanner. This is the default interface. The following pins of the 25-pin connector are used for RS232 interface connection: Pin 2 3 4 5 7
Name TX232 RX232 RTS232 CTS232 SGND Main
Function transmitted data received data request to send clear to send signal ground main interface
It is always advisable to use shielded cables. The overall maximum cable length must be less than 15 m (49.2 ft).
14
Page 27
INSTALLATION
2
DS4600
USER INTERFACE 2
TX232
3
RX232
4
RTS232
5
CTS232
7
SGND Main
RXD TXD DCD DTR SGND Earth Ground RTS/CTS HARDWARE HANDSHAKING ENABLED Figure 13 - RS232 main interface connections
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices.
Figure 14 - RS232 control signals
If the RTS/CTS handshaking protocol is enabled, the DS4600 activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
15