The text of a manual · part 2 of 6
DS4600 Installation Manual, pages 10 to 18
Pages 10 to 18 of 53
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4600
Page 10
The laser light is visible to the human eye and is emitted from the window on the front of the scanner (Figure A, 2). Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A, 4 and 10).
DATALOGIC S.p.A. Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY Model No.
Serial No.
Volt
Amp.
Manufactured This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture.
LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm TO IEC 825-1 (1993)
Warning and device class labels
For installation, use and maintenance it is not necessary to open the scanner. The laser diode used in this device is classified as a class 3B laser product according to IEC 825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the following label is reproduced here:
LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAX. OUTPUT RADIATION 30 mW EMITTED WAVE LENGTH 630~680 nm TO IEC 825-1 (1993)
Laser diode class label
Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (30 mW at 630 to 680 nm).
viii
Page 11
POWER SUPPLY - This product is intended to be installed by Qualified Personnel only. - Model DS4600-XXX0: This device is intended to be supplied by a UL Listed Direct Plug-in Power Unit marked "Class 2", rated 10-30 V, minimum 0.50 A. This device may also be supplied by a UL Listed Power Unit with a "Class 2" or LPS power source which supplies power directly to the scanner via the 25-pin connector. - Model DS4600-XXX1: This device is intended to be supplied via the Junction Box by an NEC Class 2 power source, rated 10-30 V, minimum 0.50 A. See par. 2.3.2 or 2.4.1 for correct power supply connections.
ix
Page 12
x
Page 13
GENERAL FEATURES
1
GENERAL FEATURES
1.1
INTRODUCTION
1
The DS4600 is a compact laser scanner complete with decoder designed and produced to be a flexible and affordable solution for all medium range materials handling applications. The DS4600 is a long-distance reader with performance of up to 1 meter. All models use high frequency modulated laser light for immunity to ambient light. There are models available which employ Datalogic’s powerful ACR™ (Advanced Code Reconstruction) technology, thus designed to satisfy the most demanding requirements associated with omni-directional scanning, reading of non-oriented barcode labels, and reading of poorly printed or damaged labels. Standard Application Program A Standard Application Program is factory-loaded onto the DS4600. This program controls barcode reading, serial port interfacing, data formatting and many other operating and control parameters. It is completely user configurable from a host computer using the WinHost interface utility program provided on diskette with the scanner or using the Host Mode programming procedure, by ESC sequences via the serial interface. There are four different programmable operating modes to suit various barcode reading system requirements. Included in these is a test mode to verify the reading features and exact positioning of the scanner without using external tools. Programmability If your requirements are not met by the Standard Application Program, Custom Application Programs can be developed by your local Datalogic distributor.
1
Page 14
DS4600
1
1.2
DESCRIPTION
Some of the main features of this scanner are given below: • modulated light for immunity to ambient light
• long-range reading (up to 1 meter)
• code reconstruction models available
• software programmable scanning speed (400 - 1000 scans/sec) on all standard models. (up to 1400 scans/sec optional).
• completely configurable from host computer
•
2 serial communication interfaces
• reads most popular codes
• supply voltage from 10 to 30 Vdc
• test mode to verify the reading features and exact positioning of the scanner without the need for external tools
• configurable in different operating modes to suit the most various barcode reading system requirements
• code verifier
• possibility to detect the position of the label in the scan line
The DS4600 scanner uses a solid state laser diode as a light source; the light emitted has a wavelength between 630 and 680 nm. Refer to the section "Safety Precautions" at the beginning of this manual for information on laser safety. The reader is contained in a rugged aluminum housing; the mechanical dimensions are 101 x 83.5 x 42 mm and it weighs about 800 g. The protection class of the enclosure is IP65, therefore the reader is particularly suitable for industrial environments where high protection against harsh external conditions is required.
2
Page 15
GENERAL FEATURES
1
Electrical connection is provided through a cable on the side of the reader; this cable is terminated with a 25-pin connector (25-pin connector models, see paragraph 1.3, Figure A, 1) or by a junction box (junction box models, see paragraph 1.3). The laser beam output window is on the right hand side of the scanner (Figure A, 2). A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently the laser beam is generated after a slight delay from the power on of the scanner. The four LEDs on the left hand side of the scanner indicate the following: READY
(red), indicates the reader is connected to the power supply and the startup was successful. If the startup is not successful, this LED blinks. (Figure A, 9).
GOOD READ
(red), is used to signal successful barcode decoding. It is also used in Test mode to signal the decoding percentage (for details refer to the WinHost Help On Line). (Figure A, 8).
EXT TRIG
(yellow), indicates external trigger activity (for details refer to par. 2.4.4. (Figure A, 7).
TX DATA
(green), indicates data transmission on the main serial output line. (Figure A, 6).
The screw holes on the body of the reader are for mechanical fixture (Figure A, 5); the screw holes shown in Figure A, 3 are to attach accessories such as the optional 90° mirror.
3
Page 16
DS4600
1
1.3
AVAILABLE MODELS
The DS4600 scanner is available in versions that differ in regard to the following characteristics: •
Decoding Mode
•
Linear or Raster reading
•
Reading Range
•
Cable Termination
The following models are therefore available:
DS4600 - XXXX Decoding Mode
Cable Termination
1 = Standard 3 = ACR (Avdanced Code Reconstruction)
0 = 25-pin connector 1 = junction box
Reading Range
Linear/Raster
0 = Medium Range 1 = Long Range
0 = Linear 1 = Raster Version R1 2 = Raster Version R2
1.4
ACCESSORIES
The following accessories are available on request for the DS4600:
4
•
90° deflection mirror
GFC-41
•
Oscillating mirror adapter plate
GAP-40
•
Power Block 110 Vac
PG110/DVE-1212A
•
Power Block 220 Vac
PG220/DVE-1212A
•
Oscillating mirror
GFC-05
•
20 mA Active Current Loop interface
INT-24
Page 17
INSTALLATION
2
2
INSTALLATION
2.1
PACKAGE CONTENTS
Verify that the DS4600 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: •
DS4600 reader with cable
•
Installation manual
•
Barcode test chart
•
DS4600 communication and utility program disk
•
Mounting kit: - Mounting screws and washers (4 ea.) - Mounting bracket (1)
Figure 1 - DS4600 package contents
5
Page 18
DS4600
2
2.2
MECHANICAL INSTALLATION
DS4600 can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A, 5). The diagram below gives the overall dimensions of the scanner and may be used for its installation.
83.5 3.29
101
87.9 3.46
3.98
M4 N°2
58 2.28
41.8 1.64
81 3.19
10 0.39
8.25 0.32
20 0.79
Refer to paragraph 2.5 for correct positioning.
3.75 0.15 37 1.47
23 0.90
5.5 0.22
42 1.65
R
115 4.53
R 93 3. .5 68
5 0.2
18 0.70
11.8 0.46
32.5 1.28
M4 N° 4
5.5 0.22
10°
35°
5 5. 2 2 0.
3 0.12
39 1.54
5.5 0.22
5 0.20
R2 R0 5 .98
57.3 2.26
Figure 2 - Overall dimensions
6 mm inch