The text of a manual · part 1 of 6
DS4600 Installation Manual, pages 1 to 9
Pages 1 to 9 of 53
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4600
Page 1
DS4600
Installation Manual
= >
DATALOGIC
Page 2
DS4600
Installation Manual
= >
DATALOGIC
Page 3
DS4600 INSTALLATION MANUAL
Page 4
DATALOGIC S.p.A. Via Candini 2 40012 – Lippo di Calderara di Reno Bologna - Italy
DS4600 Ed.: 02/2002
ALL RIGHTS RESERVED Datalogic reserves the right to make modifications or improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material. Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies. Datalogic S.p.A. 1999 - 2002
821000334 (Rev. D)
Page 5
CONTENTS
GUIDE TO INSTALLATION ......................................................................... v GENERAL VIEW ..........................................................................................vi SAFETY PRECAUTIONS............................................................................vii Laser Safety.................................................................................................vii Power Supply................................................................................................ix 1 1.1 1.2 1.3 1.4
GENERAL FEATURES ................................................................................ 1 Introduction ................................................................................................... 1 Description .................................................................................................... 2 Available Models........................................................................................... 4 Accessories................................................................................................... 4
2 2.1 2.2 2.3 2.3.1 2.3.2 2.4 2.4.1 2.4.2
2.4.3 2.4.4 2.4.5 2.5 2.6 2.6.1 2.6.2 2.6.3 2.6.4 2.6.5
INSTALLATION............................................................................................ 5 Package Contents......................................................................................... 5 Mechanical Installation.................................................................................. 6 Junction Box Installation ............................................................................... 7 Junction Box Mounting.................................................................................. 7 Junction Box Electrical Connections ............................................................. 9 Electrical Connections for 25-pin Models .................................................... 12 Power Supply.............................................................................................. 13 Main Serial Interface ................................................................................... 14 RS232 Interface .......................................................................................... 14 RS485 Full-Duplex Interface ....................................................................... 16 RS485 Half-Duplex Interface ...................................................................... 17 20 mA Current Loop (INT-24 Accessory Only)............................................ 19 Auxiliary RS232 Interface............................................................................ 20 Inputs .......................................................................................................... 20 Outputs ....................................................................................................... 23 Positioning .................................................................................................. 24 Typical Layouts ........................................................................................... 25 Point-to-Point .............................................................................................. 26 Pass Through.............................................................................................. 27 RS232 Master/Slave ................................................................................... 28 RS485 Master/Slave ................................................................................... 29 Multiplexer................................................................................................... 30
3 3.1 3.1.1 3.2
READING FEATURES ............................................................................... 31 Advanced Code Reconstruction.................................................................. 31 Tilt Angle for Advanced Code Reconstruction............................................. 32 Decoding Capacity in Linear Mode ............................................................. 33 iii
Page 6
3.2.1 3.2.2 3.3 3.4
Step Ladder Mode ...................................................................................... 33 Picket Fence Mode ..................................................................................... 34 Performance ............................................................................................... 35 Reading Diagrams ...................................................................................... 36
4 4.1
MAINTENANCE.......................................................................................... 38 Cleaning...................................................................................................... 38
5
TECHNICAL FEATURES ........................................................................... 39 iv
Page 7
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DS4600 scanner. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the scanner for barcode reading according to the information in paragraphs 2.2, 2.5 and 3.4. 3) Provide correct system cabling according to the signals necessary for your application (see the applicable sub-paragraphs under 2.3 or 2.4). 4) Install the Configuration Disk. Upon successful completion of the installation, the readme.hlp file is opened, giving details about how to get started configuring your scanner. See also the Guide to Rapid Configuration link. Specific parameter details are available in the Help On Line.
Fine tuning of the scanner position for barcode reading can be accomplished using the Test Mode as described in WinHost. NOTE
The installation is now complete.
v
Page 8
GENERAL VIEW DS4600
1
2 4
3 5
10 6 7 9
8
Figure A vi
1 Cable with 25-pin Connector
6 Data TX LED
2 Laser Beam Output Window
7 External Trigger LED
3 Accessory Mounting Holes
8 Good Read LED
4 Warning Label
9 Ready LED
5 Mounting Holes
10 Warning and Classification Labels
Page 9
SAFETY PRECAUTIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of the DS4600 scanner.
Standard Regulations This scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc. This product conforms to the applicable requirements of both IEC 825-1 and CDRH 21 CFR 1040 at the date of manufacture. The scanner is classified as a Class 2 laser product according to IEC 825-1 regulations and as a Class II laser product according to CDRH regulations. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the WinHost Help On Line).
WARNING
Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light.
vii