Page 46

1 DATALOGIC MEMOR™

4

Main Keys Function KEY

FUNCTION The SCAN key starts data capture. The joystick lets you move forwards, backwards, upwards or downwards, scroll through a Menu list, browse among folder files or select functions if pressed down. It can work in two functioning modes: Arrow Keys Mode and Mouse Mode. It’s possible to switch between them by pressing blue modifier + BKSP keys in sequence (see par. 4.1.2). Yellow modifier (toggle key): when pressed before a standard key, it enables the character or function printed in yellow above the key. Blue modifier (one shot key): when pressed before a standard key, it enables the character or function printed in blue above the key The ON/OFF Power button powers the Datalogic Memor ON or OFF. It is placed on the upper left side of the terminal. The ALPHA key is used to alternate numeric and alphanumeric use of the 10 numeric keys.

Special Function Icons ICON

FUNCTION

ICON

FUNCTION After a yellow modifier key press, it opens the Start menu. After a yellow modifier key press, it opens the file manager. a yellow modifier key press, it switches After a yellowAfter modifier key press, it opens the Start menu. ON/OFF the display backlight. After a blue modifier key press, it switches ON/OFF the keyboard backlight. After a yellow modifier key press, it opens the file manager.

38

After a yellow modifier key press, it switches ON/OFF the display backlight.

After a blue modifier key press, it switches ON/OFF the keyboard backlight.

After a blue modifier key press, it locks and unlocks the keyboard.

Page 47

USE AND FUNCTIONING

4

After a blue modifier key press, it locks and unlocks the keyboard.

39

Page 48

1 DATALOGIC MEMOR™

4

4.3.1

Resetting the Datalogic Memor

There are several reset methods for the Datalogic Memor. A warm boot terminates an unresponsive application and clears the working RAM, but preserves both the file system and the registry. A cold boot forces all applications to close and clears working RAM and files not resident on the persistent flash memory. Registry is restored from persistent memory if available or returned to factory default. A clean boot restores the Datalogic Memor to factory configuration: registry and file system return to factory default. Warm Boot A warm boot closes all applications, clears the working RAM, but preserves the file system and registry. If an application "hangs" initiate a warm boot to terminate the application. To perform a warm boot, press these keys simultaneously:

Cold Boot A cold boot is a complete reset of the Datalogic Memor in which all applications are forcibly closed and RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see 4.7.2) and RAM file system completely erased. You will lose any applications and data (registry too) which are not stored in persistent flash memory. A cold boot is necessary when the Windows CE operating system locks up and the warm boot command does not work. To perform a cold boot, press these keys simultaneously:

40

Page 49

USE AND FUNCTIONING

4

Clean Boot A clean boot is a cold boot that causes the device to be restored to factory configuration. The Datalogic Memor will reset to its factory configuration, clear the working RAM and initialize the file system. You will lose any applications and data stored in persistent flash memory. At the next startup the system will ask to recalibrate the touch screen. To perform a clean boot, follow these steps: 1. 2. 3. 4. 5.

Perform a Cold Boot (see Cold Boot). Quickly release all the keys when the screen goes black. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking. Release the Esc and 0 keys. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot. Warm Boot

Cold Boot

Registry

Preserved

Restored from flash (if available)

Flash Disk (Backup Folder) RAM File System

Preserved

Preserved

Preserved

Reinitialized (factory default)

Clean Boot Factory default Clean disk Factory default

41

Page 50

1 DATALOGIC MEMOR™

4

4.4

STATUS INDICATORS

4.4.1

LED Status

The Datalogic Memor provides two different LEDs signaling the mobile computer status. LED

STATUS

Good Read and General Purpose

Green

It is constant for a configurable time to signal that a successful read has occurred.

Green/ Red

It is also available to the application program.

Green

It is solid once the charging process has been completed (full charge).

Red

It is solid while charging.

Off if the charging stops due to high temperature, failures etc.

Orange it is constant while in pre-charge status

(left side)

Charging Status (right side)

42

Page 51

USE AND FUNCTIONING

4.4.2

4

Taskbar

Windows CE Taskbar

The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS

DESCRIPTION

Time and Battery Icons It displays the time. In Windows CE, they are representative of five different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. It indicates that the battery is charging Keyboard Status Icons It indicates that the blue FUNC key has been pressed and is going to affect the next key press. It indicates that the yellow FUNC key has been pressed and is going to affect the next key press. It indicates that the ALPHA key has enabled the selection of the characters printed in orange. It indicates the NUMERIC key selection, the ALPHA key has not been pressed. It indicates that the ALPHA key has enabled the selection of the characters printed in orange and the Capslock is active. It indicates that the keyboard is locked. Decoding Status Icons It indicates that the decoder is active (green), not active (grey).

43

Page 52

1 DATALOGIC MEMOR™

4

4.5

CONTROL PANEL

From the Start menu, tap Settings then Control Panel.

Windows CE Control Panel

44

Page 53

USE AND FUNCTIONING

4.5.1

4

Data Capture Configuration

From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading. The last menu item (Wedge) enables Wedge Emulation. Decoding can also be accessed from the Control Panel.

45

Page 54

1 DATALOGIC MEMOR™

4

4.5.2

Configure

The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure. The available barcode parameters are divided into two groups: Reader Parameters and Scan Parameters. The Reader Parameters depend on the type of scanner module installed on the mobile computer and allow barcode configuration (i.e. enable/disable Code 39, check digit control, etc.). The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control, laser timeout, etc.). Each Data Capture screen window corresponds to a branch of the tree, and the name of the current branch is displayed at the bottom of each screen window.

Data Capture Configuration Window

The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu. To change a value for example, select the line of the value to be changed, choose Edit from the Parameter Menu then choose a new value from the values listed in the box (see following figures).

46

Page 55

USE AND FUNCTIONING

4

Selecting Data Capture Setup Parameters

Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired value is reached. To activate a new configuration select the File ->Save Menu to send the new configuration to the barcode decoding software and save the new configuration. This will save the configuration to non-volatile memory preventing loss at the next system reset.

Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile computer. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.

Scan Parameters The Scan Parameters are common to all scanner modules and allow control of the scanning device. The Scan parameters are described as follows: ScanTimeout: the maximum time, in milliseconds, during which the scanner remains on without decoding any barcode. BeepType: if set to dual tone, the good read beep is a sequence of high and low pitch sounds. If set to monotone, the beep is a single pitch sound. BeepDuration: the time interval, in milliseconds, during which the beeper will sound when the scanner reads a code. To disable the beeper, set this value to 0.

47