The text of a manual · part 6 of 18
Datalogic Memor Mobile Computer User's Manual: 4 USE AND FUNCTIONING, pages 36 to 45
Pages 36 to 45 of 138, from Datalogic Memor Mobile Computer User's Manual
The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DL Memor
Page 36
1 DATALOGIC MEMOR™
4
4
USE AND FUNCTIONING
The use of the Datalogic Memor depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc
4.1
STARTUP
The Datalogic Memor turns on when the battery pack or the external supply is inserted and the ON/OFF Power button is pressed. After the battery pack is installed, use the [ON/OFF] key to turn the mobile computer on and off. As soon as the mobile computer is on, the Windows CE 5.0 desktop will appear on the screen. Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure.
Desktop
Control Panel
Use the stylus (par. 4.1.1) or joystick (par. 4.1.2) as suggested to select icons and options. The mobile computer goes into power-off (low power with display and keyboard backlight off), when it is not used for more than a programmable timeout, which is
28
Page 37
USE AND FUNCTIONING
4 defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key.
The mobile computer can also be awakened or suspended programmatically. NOTE
29
Page 38
1 DATALOGIC MEMOR™
4
4.1.1
Using the Stylus
The stylus selects items and enters information. The stylus functions like a mouse. Double Tap:
Double tap the screen with the stylus to open items and select options.
Drag:
Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items.
Tap-and-hold:
Tap and hold the stylus on an item to see a list of actions available for that item. On the pop-up menu that appears, tap the action you want to perform.
To recalibrate the touch screen use the Stylus applet (see par. 4.6.7). Use only original Datalogic styluses supplied with the product itself. In harsh applications, use of screen protectors should be taken into consideration, in order to extend the touch screen operating life. CAUTION
To prevent damage to the screen, do not use sharp devices or any device other than the Datalogic provided stylus. Do not apply too much pressure when touching the screen. For applications where an intensive use of the touch screen is foreseen, please consider that touch screen components are subject to progressive wear.
30
Page 39
USE AND FUNCTIONING
4.1.2
4
Using the Joystick
The joystick selects items and enters information. The joystick can work like the directional arrow keys of a PC keyboard or can function like a mouse and control the mouse pointer. It is possible to switch between the two functioning modes by pressing blue modifier + BKSP keys in sequence. Arrow Keys Mode (default):
Move in the four directions: move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files. Press down: selects the current function (like the Enter key).
Mouse Mode:
Move in the four directions: move the mouse pointer forwards, backwards, upwards or downwards. Press down: like the left click of the mouse.
31
Page 40
1 DATALOGIC MEMOR™
4
4.1.3
Windows CE Touch Screen Calibration
In Windows CE, at the very first Datalogic Memor startup, following a clean boot to restore the Registry to default values, the mobile computer startup (see par. 4.1) is preceded by the touch screen calibration screen. The user must calibrate the touch screen (see par. 4.5.7)
Touch Screen Calibration Screen
32
Page 41
USE AND FUNCTIONING
4.2
4
DATA CAPTURE
To capture data tap Start > Settings > Control Panel > double tap Decoding:
To configure and enable data capture parameters refer to par. 4.5.1.
33
Page 42
1 DATALOGIC MEMOR™
4
4.2.1
Laser Data Capture
To scan barcodes, point the Datalogic Memor laser model onto the code from a distance within the reading range while pressing the SCAN key. The lighted band emitted by the laser must completely cross the barcode as shown in the figure below.
If the scan has taken place correctly: − − − the Good Read LED glows steadily Green for a configurable time; if enabled, the Good Read Beep plays; if enabled, the GreenSpot projects a green spot onto the bar code image.
Remove the protective film cover over the data capture window before use. NOTE
34
Page 43
USE AND FUNCTIONING
4.2.2
4
Imager Data Capture
The Datalogic Memor Imager captures a picture of the entire bar code. The omnidirectional scanning does not require that the operator orient the bar code to align with the scan pattern. To read a 1D or 2D code, simply point the Datalogic Memor Imager model onto the code and press the SCAN Key or the pistol trigger.
The Datalogic Memor Imager uses an intelligent aiming system pattern, similar to those on cameras, indicating the field of view, which should be positioned over the code:
Aiming System
If the aiming system pattern is centered over the entire symbology as shown in the following figure, either wait for the timeout or release the Scan key or the trigger to capture the image. A red beam illuminates the code, which is captured and decoded. You will get a good read.
35
Page 44
1 DATALOGIC MEMOR™
4
Linear barcode
2D Matrix symbol
ÌBX3ÉÎ
Relative Size and Location of Aiming System Pattern
The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the Datalogic Memor Imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. 5.1 for further details). If the scan has taken place correctly: − −
36 the Good Read LED glows steadily Green for a configurable time; if enabled, the Good Read Beep plays.
Page 45
USE AND FUNCTIONING
4.3
4
DESCRIPTION OF THE KEYBOARDS
The Datalogic Memor comes with a 23-key alphanumeric keyboard + ON/OFF key + joystick.
37