The text of a manual · part 5 of 18
Datalogic Memor Mobile Computer User's Manual: 3 CONNECTIONS
Pages 25 to 35 of 138, from Datalogic Memor Mobile Computer User's Manual
The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DL Memor
Page 25
CONNECTIONS
3
CONNECTIONS
3.1
USB CONNECTION
3
You can use any standard mini USB cable to directly connect the Datalogic Memor to a host computer to transfer data through the USB interface. A C B
Key: A
Host computer
B
Standard Mini USB cable
C
Datalogic Memor
Connection through the cable is compliant to 2.0 USB standard. NOTE
17
Page 26
1 DATALOGIC MEMOR™
3
The Single Dock can be connected to the host computer by any standard mini USB cable. Once the host computer has been turned on, insert the Datalogic Memor mobile computer into the cradle. A C B
D
Key: A
Host computer
C
Single Slot Dock
B
Standard Mini USB cable
D
Power Supply (only † battery charging )
necessary for
Connection through the cradle complies to USB 1.1 standard. NOTE
The actual data transfer speed can be appreciably lower than the maximum theoretical speed. NOTE
18
Page 27
CONNECTIONS
3.2
3
CONNECTION TO USB PERIPHERALS
You can connect the Datalogic Memor to a standard 101-key USB keyboard or to a standard USB flash memory device. Connect the terminal to a standard A (4 pin female) to mini A (5 pin male) USB cable. For all these devices maximum current draw must be less than 100mA. B
A C
Key: A
Keyboard with USB interface
B
Datalogic Memor
C
94A051024 (Standard A to Mini A USB cable)
B
A C
Key: A
USB hard drive/ external memory source
B
Datalogic Memor
C
94A051024 (Standard A to Mini A USB cable)
Connect first the USB peripheral to the cable, and then the cable to the Datalogic Memor. NOTE
19
Page 28
1 DATALOGIC MEMOR™
3
The Datalogic Memor works with most of the mentioned USB peripherals. Datalogic cannot guarantee the interoperability of Datalogic Memor with all devices on the market. NOTE
Connection is compliant to USB 1.1 standard. NOTE
The actual data transfer speed can be appreciably lower than the maximum theoretical speed. NOTE
20
Page 29
CONNECTIONS
3.3
3
RS232 CONNECTION
You can use a cable to directly connect the Datalogic Memor to a host computer to transfer data through the RS232 interface: A C B
Key: A
Host computer
B
94A051022 WIN-NET (HRS ST40X-18S-CV)
C
Datalogic Memor
The Single Slot Dock can be connected to the Host by means of a standard null modem cable such as Datalogic 94A051020 CAB-427 for 9-pin connections. Once the host computer has been turned on, insert the Datalogic Memor mobile computer into the dock. A B
C
D
Key: A
Host Computer
C
Single Slot Dock
B
94A051020 CAB-427 RS232 Null Modem Cable
D
Power Supply (only necessary for battery charging) ∗
∗ In this case the power supply is only necessary for battery charging. Insert the power supply plug into the power jack on the base of the cradle and attach the power supply to a power outlet.
21
Page 30
1 DATALOGIC MEMOR™
3
3.4
WLAN CONNECTION
Datalogic Memor 802.11 abg radio models can communicate with the host using the on-board Wi-Fi radio and an Access Point connected to a network. A
A
B
C
Key: A) Datalogic Memor B) Access point C) Host – Application Server
22
Page 31
CONNECTIONS
3
802.11 abg radio module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communications tab. NOTE
NOTE
Suspending the terminal powers off the 802.11 a/b/g radio and drops the radio connection. When the terminal resumes, depending on the radio power mode and security protocol selected, it may take up to 30 seconds for the 802.11 a/b/g radio driver to re-associate the radio to the network.
Area coverage and radio performance may vary, due to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.). NOTE
In case of heavy usage the Datalogic Memor may get warm; this is normal and does not mean a malfunction. NOTE
23
Page 32
1 DATALOGIC MEMOR™
3
3.5
WPAN CONNECTIONS
Datalogic Memor Bluetooth® models can communicate with a Bluetooth® device, such as a printer, within a range of 10 m, using the on-board Bluetooth® module.
B
A
Key: A) Datalogic Memor B) Bluetooth® printer
NOTE
In order to extend battery life, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications tab (see par. 4.5.7), and perform the Discovery procedure (see par. 4.6.2).
NOTE
Suspending the terminal powers off the Bluetooth® radio and drops the piconet (Bluetooth® connection). When the terminal resumes, it takes approximately 10 seconds for the Bluetooth® radio driver to reinitialize the radio.
Area coverage and Bluetooth® radio performance may vary, due to environmental conditions or interference caused by other devices (microwave ovens, radio transmitters, etc.). NOTE
24
Page 33
CONNECTIONS
3.6
3
CONNECTION CABLES RS232 Direct Connection: 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV)
Datalogic Memor™ side 9
RXD
TXD
TXD
RXD
CTS
RTS
RTS
CTS
10 11 12
3
HOST/PC side 9-pin (female)
2 7 8
DSR 13 DCD
DTR
DTR
DCD
4
15
1
14 DSR
6 8 7
RI
RI
GND
GND
9 5
Power Supply Polarity: VEXT
GND
25
Page 34
1 DATALOGIC MEMOR™
3
3.7
WIRELESS AND RADIO FREQUENCIES WARNINGS
Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications or attachments could damage the product and may violate laws and regulations. WARNING
Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals generated by the Datalogic Memor. WARNING Datalogic recommends persons with pacemakers or other medical devices to follow the same recommendations provided by Health Industry Manufacturers Associations for mobile phones. Persons with pacemakers: WARNING
•
Should ALWAYS keep this device more than twenty five (25) cm from their pacemaker and/or any other medical device;
•
Should not carry this device in a breast pocket;
•
Should keep the device at the opposite side of the pacemaker and/or any other medical device;
•
Should turn this device OFF or move it immediately AWAY if there is any reason to suspect that interference is taking place.
•
Should ALWAYS read pacemaker or any other medical device guides or should consult the manufacturer of the medical device to determine if it is adequately shielded from external RF energy. In case of doubt concerning the use of wireless devices with an implanted medical device, contact your doctor.
26
Page 35
CONNECTIONS
WARNING
3
Turn this device OFF in health care facilities when any regulations posted in these areas instruct you to do so. Hospitals or health care facilities may use equipment that could be sensitive to external RF energy.
WARNING
RF signals may affect improperly installed or inadequately shielded electronic systems in motor vehicles. Check with the manufacturer or its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle.
WARNING
An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If a vehicle’s wireless equipment is improperly installed and the air bag inflates, serious injury could result.
WARNING
Turn off the device when in any area with a potentially explosive atmosphere. Observe restrictions and follow closely any laws, regulations, warnings and best practices on the use of radio equipment near fuel storage areas or fuel distribution areas, chemical plants or where any operation involves use of explosive materials. Do not store or carry flammable liquids, explosive gases or materials with the device or its parts or accessories. Areas with a potentially explosive atmosphere are often, but not always, clearly marked or shown. Sparks in such areas could cause an explosion or fire, resulting in injury or even death.
To safely disable the radio modules (WiFi/BT) do not power off the mobile computer, but use the Wireless Communications tab (see par.4.5.7). WARNING
27