The text of a manual · part 4 of 18
Datalogic Memor Mobile Computer User's Manual: 2 BATTERIES AND MAINTENANCE
Pages 17 to 24 of 138, from Datalogic Memor Mobile Computer User's Manual
The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DL Memor
Page 17
BATTERIES AND MAINTENANCE
2
2
BATTERIES AND MAINTENANCE
NOTE
Rechargeable backup batteries and battery packs are not initially fully charged. Therefore the initial operation to perform is to charge them. See below.
Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and ensures maximum performance. CAUTION
2.1
CHARGING THE BATTERY PACK The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc.
NOTE
The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Datalogic Memor. Alternatively, it is also possible to recharge the battery pack by inserting the Datalogic Memor into the single slot dock or the multi battery charger. Moreover recharging is possible by USB Direct connection with the host computer, but with longer charging times and only if the mobile computer off. During the charging process the LED positioned at the right side of the display is red constant. Once the charging process has been completed this LED is green constant (see par. 4.4). The stand alone battery pack may be recharged outside a Datalogic Memor using the spare battery charging slot on the back of the single slot dock or the multi battery charger.
9
Page 18
2
1 DATALOGIC MEMOR™
Do not use the Datalogic Memor until batteries are charged for minimum 4 hours. CAUTION
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. CAUTION
Il y a risque d’explosion si la batterie est remplacée par une batterie de type incorrect. CAUTION
Mettre au rebut les batteris usagées confor mément aux instructions.
Even if the storage temperature range is wider, in order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30º C (68 to 86º F). NOTE
Datalogic Memor (including spare battery) should be charged at an ambient temperature between 0° to +40 °C (+32° to +104 °F) to achieve the maximum charging rate. Never charge the main device or spare batteries in a closed space where excessive heat can build up.
The battery level may display incorrectly for several minutes after the Datalogic Memor is disconnected from its charger if the charging cycle is not completed. NOTE
10
Page 19
BATTERIES AND MAINTENANCE
2
The Datalogic Memor may get warm during charging; this is normal and does not mean a malfunction. NOTE
Use only a USB-IF compliant USB port as a charging source. NOTE
11
Page 20
1 DATALOGIC MEMOR™
2
2.2
REPLACING THE BATTERY PACK
To correctly replace the battery pack, proceed as follows. 1.
Turn off the Datalogic Memor.
2.
Press the latch release button and pull the battery latch down :
3.
Remove the cover and the battery pack.
12
Page 21
BATTERIES AND MAINTENANCE
2
4.
Install the new battery pack, first insert the bottom (contacts) side, then the upper side:
5.
Press the latch release button and pull the battery latch down to reinsert the cover
Installing, charging and/or any other action should be done by authorized personnel and following this manual. WARNING
The battery pack may get hot, explode, ignite, and/or cause serious injury if exposed to abusive conditions. If the battery pack is replaced with an improper type, there is risk of explosion and/or fire. Do not place the battery pack in or near a fire or other heat source; do not place the battery pack in direct sunlight, or use or store the battery pack inside unventilated areas in hot weather; do not place the battery pack in microwave ovens, in clothes dryers, in high pressure containers, on induction cook surfaces or similar devices. Doing so may cause the battery pack to generate heat, explode or ignite. Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy. Use only a Datalogic approved power supply. The use of an alternative power supply will void the product warranty, may cause product damage and may cause heat, an explosion, or fire. The area in which the units are charged should be clear of debris and combustible materials or chemicals. Do not use the battery pack of this terminal to power devices other than this mobile computer.
13
Page 22
1 DATALOGIC MEMOR™
2
WARNING
Immediately discontinue use of the battery pack if, while using, charging or storing the battery pack, the battery pack emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way. Do not short-circuit the battery pack contacts connecting the positive terminal and negative terminal. This might happen, for example, when you carry a spare battery pack in your pocket or purse; accidental short–circuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery pack (these look like metal strips on the battery pack). Short– circuiting the terminals may damage the battery pack or the connecting object. Do not apply voltages to the battery pack contacts. Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts, pressures, or shocks. Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection devices, which, if damaged, may cause the battery pack to generate heat, explode or ignite. In case of leakage of liquid from the battery, avoid contact with liquid the skin or eyes. If the contact occurs, immediately wash the affected area with water and consult a doctor. Do not solder directly onto the battery pack. Do not expose the battery pack to liquids. Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on a hard surface, you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery pack’s label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised. Collect and recycle waste batteries separately from the device in compliance with European Directive 2006/66/EC, 2011/65, 2002/96/EC and subsequent modifications, with US and China regulatory laws and regulations about the environment.
14
Page 23
BATTERIES AND MAINTENANCE
2
In order to maximize operating autonomy, the Datalogic Memor checks its battery level at all times. If the battery is not sufficiently charged, the Datalogic Memor will not turn on when the ON/OFF Power button is pressed. NOTE
In this case, either substitute a sufficiently charged battery, insert the Datalogic Memor into a powered cradle, or plug it into a wall charger.
To maximize battery life, turn off radios when they are not needed. NOTE
15
Page 24
1 DATALOGIC MEMOR™
2
2.3
CLEANING THE MOBILE COMPUTER
Periodically clean the Datalogic Memor with a slightly dampened cloth. Do not use alcohol, corrosive products or solvents.
16