The text of a manual · part 8 of 18
Datalogic Memor Mobile Computer User's Manual: 4 USE AND FUNCTIONING, pages 56 to 65
Pages 56 to 65 of 138, from Datalogic Memor Mobile Computer User's Manual
The original document is the PDF (8.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DL Memor
Page 56
4
1 DATALOGIC MEMOR™
BeepFrequency: determines the frequency in Hertz of the beeper. GoodReadSound: is the beep sound emitted when the scanner reads a code. LedDuration: the length of the good-read led pulse, in milliseconds. LedPulses: the number of times the good-read led pulse is emitted when the scanner reads a code. ContinuousMode: disables the effect of the ScanTimeout parameter. KeyboardEmulation: if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved to a file as if input from the mobile computer keyboard. SoftTrigger: when enabled, the laser can be turned on/off by the application software. ScanAlwaysOn: enables the scanner for barcode reading independently from the application software. GreenSpotDuration: determines the duration (measured in milliseconds) of the green spot feedback, which provides a “good read” green dot directly on the code, where the operator usually tends to be looking. NotPrintableChar: if set to “Remove”, all not printable characters included in the scanned data are deleted and the final barcode will include only printable characters. ScanButton: enables/disables the scan button. If the scan button is disabled, the reader can be triggered under software control.
48
Page 57
USE AND FUNCTIONING
4
Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the mobile computer. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. SCAN PARAMETERS ScanTimeout BeepType BeepDuration BeepFrequency GoodReadSound LedDuration LedPulses ContinuousMode KeyboardEmulation SoftTrigger ScanAlwaysOn GreenSpotDuration NotPrintableChar ScanButton BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS UPC A UPC E EAN 8 EAN 13 UPC/EAN/JAN Code 39 Code 39 Full ASCII Code 32 2/5: Interleaved 2/5: Industrial 2/5: Matrix Code 128 EAN 128 CODABAR
LASER MODELS 5000 Dual tone 20 2000 Beep 200 ms 1 Disabled Enabled Enabled Disabled 1000 Leave Enabled
IMAGER MODELS Not available Not available Not available Not available Beep.wav 200 ms 1 Disabled Enabled Enabled Disabled Not available Leave Enabled
LASER MODELS
IMAGER MODELS
Enabled Enabled Enabled Enabled Not available Enabled Disabled Disabled Enabled Disabled Disabled Enabled Enabled Disabled
∗
Enabled Enabled Disabled Not available Enabled Not available Not available Enabled Disabled Enabled
∗
In the Imager models these codes may only be enabled or disabled as a group by the UPC/EAN/JAN family selection (see a few lines below).
49
Page 58
1 DATALOGIC MEMOR™
4
BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS MSI Plessey Code 93 Code 11 GS1 Databar GS1 Databar Omnidirectional GS1 Databar General GS1 Databar Limited GS1 Databar Expanded PDF - 417
Data Matrix QR POSTNET PLANET Japan Post Australia Post KIX Code Royal Mail Code (RM4SCC)
∗
LASER MODELS
IMAGER MODELS
Disabled Disabled Disabled Disabled Disabled Disabled Not available Disabled Disabled Not available Not available Not available Not available Not available Not available Not available Not available Not available
Not available Not available Enabled Not available Enabled Not available Enabled Enabled Enabled Enabled Enabled Enabled
Disabled ∗
These codes may be enabled individually but are disabled as a group.
50
Page 59
USE AND FUNCTIONING
4.5.3
4
Capture
The Data Capture applet (Capture) enables code reading.
Data Capture Window
Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch.
Enabling the Data Capture
51
Page 60
1 DATALOGIC MEMOR™
4
4.5.4
Buttons
You can use the Buttons Tab to associate specific keys, such as <F1>-<F4>, with specific applications. From the control panel main window, double tap the DL Buttons icon. On the Buttons tab, customize the program hardware buttons to launch your most used applications. Select the button you want to assign a function to, and then browse to select the application to be assigned.
You can also select to wake up the terminal by the SCAN key.
52
Page 61
USE AND FUNCTIONING
4.5.5
4
Registry
The Registry stores information that are necessary to configure the system for applications and hardware devices. The Registry also contains information that the operating system continually references to during operation. From the Control Panel, double tap the “Registry Admin” icon. Two functions are available: -
Save Registry allows permanently saving the Windows configuration (example: custom configuration of screen desktop background color, or network adapter configuration) to non-volatile memory (‘Save’ button).
-
Restore Default Registry allows restoring the initial factory default configuration (‘Restore Default’ button). After restoring the factory default configuration, you must perform a warm boot.
53
Page 62
1 DATALOGIC MEMOR™
4
4.5.6
Files Admin
The Files Admin applet enables control of the permanence of files in the Windows CE System Folder.
Files Admin Main Window
Two functions are available: Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory. This function guarantees the steady maintenance of every file produced during the current working session - even of sub-directories and relevant files - with the exception of the files belonging to the FLASH image. These current working session files will be backed-up in the \Backup\Windows directory. At the next cold boot, the files previously saved in the \Backup\Windows directory will be restored to the Windows directory. Safe Setup: with this button, the installation of software programs will be saved to non-volatile memory (Backup directory). Before doing this, it will be checked that the Backup directory has enough space to save the files. If the directory space is not enough, an error message will be shown and the program will exit the Safe Setup function.
54
Page 63
USE AND FUNCTIONING
4
Two activating procedures are available for Safe Setup: -
Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask.
Safe Setup First Mask
Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next cold boot, these files will be restored (see par. 4.9). -
Simply skip the first mask either by closing it or by pressing the ESC key. When it closes, a new mask will pop up: it will enable any type of installation (even ® remote ones like ActiveSync installations). Make sure the installation directory is \Windows or one of its sub-directories. After installation, tap OK: Safe Setup will save the new files in the \Backup\Windows directory.
55
Page 64
56
9 Install your program, then De) press the OK button to Manaq tmake this installation
« permanent.
Error Files Admin Input Panel Reporting pp, O@ By, i [>|
File View x eo] i ~ > YW ®w-, Date/Time Decoding Device Info __} PelSAFE SETUP OK} bid Li LEP.
Y Gel nsw ew AS
Safe Setup Second Mask
DATALOGIC MEMOR™
Page 65
USE AND FUNCTIONING
4.5.7
4
Wireless Communications
The Wireless Communications applet provides management of the 802.11 abg radio and the Bluetooth modules. From the Control Panel, double tap the ‘Wireless Communications’ icon:
57