Page 158
GRYPHON™
6
6
TECHNICAL FEATURES
6.1
GRYPHON™ D
Electrical Features Supply Voltage Consumption Maximum Operating Sleep Mode
5 Vdc ± 5% 330 mA 250 mA 250 µA
Optical Features Sensor Scan Rate (max) Reading field Resolution (max) PCS (min) (Datalogic Test Chart)
CCD solid state (3648 pixels) 270 scans/sec see reading diagram (par. 6.6) 0.0076 mm (3 mils) 15%
Environmental Features Working Temperature
0° to +55 °C / +32° to +131 °F
Storage Temperature
-20° to +70 °C / -4° to +158 °F
Humidity
90% non condensing
Drop resistance
IEC 68-2-32 Test ED
Protection Class
IP30
Mechanical Features Weight (without cable) Dimensions Material
148 about 200 g. (7 oz.) 179 x 81 x 98 mm / 7.04 x 3.18 x 3.85 in ABS and Polycarbonate molded with rubber
Page 159
TECHNICAL FEATURES
6.2
6
GRYPHON™ M
Electrical Features Battery Type Time of recharge NiMh Operating autonomy (typ. continuous reading) Indicators
2 AA NiMh* batteries 1.2 V – 1400 mAh From 3 to 5 hours 25,000 reads - NiMh LED, Good Read Spot, Beeper
Optical Features Sensor Scan Rate (max) Reading field Resolution (max) PCS (min) (Datalogic Test Chart)
CCD solid state (3648 pixels) 270 scans/sec see reading diagram (par. 6.6) 0.076 mm, (3 mils) 15%
Environmental Features Working Temperature Storage Temperature (without battery) Humidity Drop resistance Protection class
0 to +40 °C / +32° to +104 °F -20 to +70 °C / -4° to +158 °F 90% non condensing IEC 68-2-32 Test ED IP30
Mechanical Features Weight (with batteries) Dimensions Material
* about 280 g. / 9.87 oz 179 x 81 x 98 mm / 7.04 x 3.18 x 3.85 in ABS and Polycarbonate molded with rubber
It is possible to employ also NiCd or non-chargeable Alkaline AA batteries.
149
Page 160
GRYPHON™
6
6.3
OM-GRYPHON™ / C-GRYPHON™ OM-GRYPHON™
C-GRYPHON™
Electrical and General Features Supply Voltage Power Consumption (max) Indicators Recharge Time NiMh / NiCd batteries
9 to 28 Vdc 8 W (charging) * Battery Charging LED (red) Charge completed LED (green) Power/Data LED (yellow) From 3 to 5 hours
Host Interfaces RS232
150 to 38400 baud
9600 baud
WEDGE
IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported
Not supported
PEN Emulation
Selectable minimum pulse from 200 µS to 1.2 mS
Environmental Features Working Temperature
0 to +40 °C / +32° to +104 °F
Storage Temperature
-20 to +70 °C / -4° to +158 °F
Humidity
90% non condensing
Protection
IP30
Mechanical Features Weight (without cable) Dimensions Material about 250 g. / 8.81 oz. 208 x 107 x 55.5 mm / 8.1 x 4.2 x 2.18 in ABS
* Having a switching regulator inside, the OM-GRYPHON™ and C-GRYPHON™ draw the same power, regardless of the supply voltage. i.e. as the input voltage increases the current drawn decreases.
150
Page 161
TECHNICAL FEATURES
6.4
6
SYSTEM AND RADIO FEATURES
Radio Features
European Models 433.92 MHz
USA Models 910 MHz
Bit Rate
19200
36800
Effective Radiated Power
<10 mW
<1 mW
Working Frequency
Range (in open air)
30 m
RF Modulation
System Configurations
OM-GRYPHON™
STARGATE™
16
255
Maximum number of devices per base stations Maximum number of devices in the same reading area Maximum number of base stations in network
6.5
15 m FSK
2000 16
STATUS INDICATORS
The reader has three indicators, LED, Beeper and Good Read Spot. The OMGRYPHON™ and C-GRYPHON™ cradles have three indicator LEDs. They signal several operating conditions which are described in the tables below. H = high tone
L = low tone
GRYPHON™ D/M READER START-UP Beeper¹
Meaning
LLLL
Parameters loaded correctly
H H H H long tones HLHL
Parameter loading error, reading or writing error in the non volatile memory Hardware error in EEPROM
GRYPHON™ D/M READER CONFIGURATION Beeper¹
Meaning
HHHH
Correct entry or exit from Configuration mode
L LLL
Good read of a command Command read error
151
Page 162
GRYPHON™
6 GRYPHON™ D/M READER DATA ENTRY Beeper¹
LED one beep²
ON
Good Read Spot Meaning ON
Correct read of a code in normal mode
H L long
TX buffer full (when FIFO is enabled) or TX error between GRYPHON™ M and OMGRYPHON™
H long
ON
ON
Successful advanced format concatenation
HHH
Timeout expired – operation not completed
H H long
Error in advanced data formatting OFF
OFF
Ready to read a code
GRYPHON™ M POWER Beeper
LED
Meaning
10 short H
10 short blinks
Low Battery
GRYPHON™ M BIND, JOIN, COPY COMMANDS Beeper¹
LED Blinking
Meaning Command accepted; reader ready to be inserted into the cradle
L
Success
H L long tones
Failure
¹ Only the Beeper Intensity command can modify these signals. ² The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section. For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether OM-GRYPHON™ has received the data. See also par. 5.7.3.
152
Page 163
TECHNICAL FEATURES
6
OM-GRYPHON™/C-GRYPHON™ CHARGE STATUS Red LED
Green LED
Meaning
ON
ON
Charging
OFF
ON
End of charge
OFF
OFF
No battery inserted
Flashing
OFF
Discharging (see par. 2.8.2)
Flashing
Flashing
Shorted or open battery
OM-GRYPHON™/C-GRYPHON™ POWER/COMMUNICATION Yellow LED
Meaning
ON
Power applied
OFF
Error in reading EEPROM parameters
Blinking
6.6
Transmission over the Host port
READING DIAGRAMS GRYPHON™ D/M100 Reading Zones (10° skew angle)
15
0.13 mm (5 mils)
10
5 CODE 39 0.076 mm (3 mils)
0
CODE 39 0.13 mm (5 mils)
EAN13 M=1 0.33 mm (13 mils)
CODE 39 0.50 mm (20 mils)
-5
-10
-15
0
5
10
15
20
25
30
35
(cm)
153
Page 164
GRYPHON™
6 GRYPHON™ D/M200 Reading Zones (10° skew angle)
10 0.13 mm (5 mils)
5
0
CODE39 0.076 mm (3 mils)
CODE39 0.13 mm (5 mils)
10
15
EAN13 M=1 0.33 mm (13 mils)
CODE39 0.50 mm (20 mils)
-5
-10
0
5
20
25
30
35
Reading Zones (10° skew angle) 8 PDF417 Aspect Ratio 3:1 6
4
2 0.17 mm (6.6mils)
0.38 mm (15mils)
0
-2
-4
-6 0.25 mm (10mils) -8 0
154
2
4
6
8
10
12
14
16
(cm)