For the Datalogic D100 and Datalogic M100

Page 148

GRYPHON™

5

5.4.3

Standby

If this command is enabled, part of the CCD circuitry shuts down (Standby), in order to optimize low power consumption when not reading. When the trigger is pressed this circuitry powers up. This mode causes a minor delay of about 100 ms before the reader is ready. For M-series readers, standby is always enabled and is not configurable. To exit Standby press the trigger.

5.5

READING PARAMETERS

5.5.1

Operating Mode

This group of parameters allows setting different reading modes for either Hand-Held operation or Stand operation: •

SoftwareTrigger: the reader is set in FLASH MODE. Code reading takes place during the flash on time;

•

Hardware Trigger: the code reading is started with a trigger press (ON);

•

Hardware Trigger Ready: the illuminator is switched ON when the reader sees a code. It functions as a pointer aiming at the code to be read. The reading phase starts only when the trigger is pressed. In this mode the reader is automatically set to trigger active level and one read per cycle parameters. (Only for Handheld operation).

•

Automatic: The illuminator is switched ON when the reader sees a code. The reading phase starts automatically.

•

Always ON: the illuminator is always ON and the reader always ready for code reading. This value is not available for M-series readers.

5.5.2

Hardware Trigger Mode

This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected: • trigger active level: the reader goes ON when the trigger is pressed and goes OFF when it is released

• trigger active pulse: the reader goes ON at the first trigger press and goes OFF only at a second press

138

Page 149

TECHNICAL FEATURES

5.5.3

5

Trigger-Off Timeout

When this timeout is selected, the reader turns OFF automatically after the desired period of time.

5.5.4

Reads per Cycle

In general, a reading cycle corresponds to the ON + OFF times of a device. The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times. •

For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time.

•

For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events: trigger release (for trigger active level) a second trigger press (for trigger active pulse) trigger-off timeout (see par. 5.5.3).

When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It is only possible to read another code when the next ON time occurs. In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For software trigger mode, the flash on period is immediately reset after each read and therefore extended. If another code is decoded before the reset flash on period expires, it is again reset and the effect is that the device remains ON, decoding codes until the flash on or timeout period expires. The Safety Time parameter should be used in this case to avoid unwanted multiple reading of the same code, see par. 5.5.5.

5.5.5

Safety Time

Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to be removed from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes. The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode, since these settings require voluntary action by the user.

139

Page 150

GRYPHON™

5

5.6

DECODING PARAMETERS

CAUTION

5.6.1

These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.

Ink-Spread

The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink.

5.6.2

Overflow Control

The overflow control parameter can be disabled when decoding codes printed on small surfaces, which do not allow the use of an overflow space. This command does not effect code families 2/5, Code 128 and Code 93. This command is forced (enabled) when PDF417 codes are enabled.

5.6.3

Interdigit Control

The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.

5.7 5.7.1

RADIO PARAMETERS (M SERIES ONLY) Radio Protocol Timeout

This parameter sets the valid time to wait before transmission between the M series reader and OM-GRYPHON™ cradle is considered failed. This parameter should be set taking into consideration the radio traffic (number of readers in the same area). If the RS232 interface is used with ACK/NACK enabled, this parameter should be at least equal to the RX Timeout parameter for low traffic environments. It should be increased if there are many readers in the same area. It can be set between 2 and 19 seconds.

140

Page 151

TECHNICAL FEATURES

5.7.2

5

Power-Off Timeout

If this command is enabled, after the desired timeout in hours, the GRYPHON™ batteries are disconnected and all power consumption ceases. To restore power, press the trigger once. The reader will now be ready to read codes. Power-off does not effect configuration parameters.

5.7.3

Beeper Control for Radio Response

For M-Series readers, the data entry good read tone normally results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether OM-GRYPHON™ has received the data. This can be changed according to the following selections: ♦ Normal: both good decode and good reception are signaled (two beeps). ♦ Only Good Decode: only the first beep indicating a good read is signaled. ♦ Only Good Reception: only the second beep indicating a good reception is signaled. ♦ Off: Neither good read nor good reception beeps are signaled. For all configurations, any transmission errors will always be signaled.

5.7.4

Single Store

When single store mode is enabled, if the GRYPHON™ M fails to transmit a code to the cradle, it enters a special operating mode that prevents the user from reading barcodes. When such operating mode is entered, the trigger no longer enables barcode reading but is used to retry transmission itself for the number of attempts selected in configuration. Once the transmission is successful the reader returns to the standard mode. If transmission is not successful after the number of configured attempts, the code is discarded. Single store may be useful if you often read codes at the limit of the coverage area and there is a chance that code transmission can fail. In such case single store allows you to move to a more favorable position or location (i.e. closer to the cradle) and retry transmission without the necessity of re-reading the code since it is already stored in the reader. Conversely, if single store is disabled, and the user wants to retry transmission, the code must be read again, and therefore the attempt must be made from basically the same location. If the user gives up, he does not know if the transaction was successful. (Actually the transmission could have been successful but the cradle may have been unable to acknowledge the message). There are applications in which there is no risk of transmission failure. In such cases it may be better to disable single store so that the user perceives a more consistent behavior of the trigger in that it always corresponds to code reading.

141

Page 152

GRYPHON™

5

5.8

CONFIGURATION EDITING COMMANDS

The following commands carry out their specific function and then exit the configuration environment. Command i i i

Pk Pk Pk i i i i i i i i i

39 39 39 i i i i i i

142

Description Restore GRYPHON™ reader default configuration (see the relative Quick Reference Manual for default settings)

Transmit the GRYPHON™ D or GRYPHON™ M Software release

Transmit GRYPHON™ reader configuration in ASCII format. This command is not effective with Pen emulation interface or with the GRYPHON™ D200 reader model. Restore OM-GRYPHON™ default configuration (see the relative Quick Reference Manual for default settings)

Transmit the OM-GRYPHON™ Software release.

Transmit OM-GRYPHON™ configuration in ASCII format. This command is not effective with Pen emulation interface.

Page 153

TECHNICAL FEATURES

5.9

5

CONFIGURATION COPYING COMMANDS

5.9.1

Copy GRYPHON D-Series

Procedure: Connect the master (correctly configured reader) and the slave (reader to be configured) together through two RS232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection. RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328 Power Supply: PG5 Using the slave reader, read the Restore Default barcode and then the RS232 interface barcode from chapter 4 of this manual or from the Quick Reference Manual. With the master reader, read the Configuration Copy barcode below.

Copy Configuration i i i

;; ;; ;;

k k k

$+ZZ0$The configuration will be copied from the master to the slave reader. The slave reader signals the end of the procedure with a series of beeps. Note: The master reader can be configured for any interface.

143

Page 154

GRYPHON™

5

5.9.2

Copy GRYPHON M-Series

Procedure: Using the slave reader and its OM-GRYPHON™ cradle, follow the initialization procedure in chapter 4 of this manual or from the Quick Reference Manual. With the master GRYPHON M (correctly configured reader), read the Copy Configuration barcode below. Then place it onto an OM-GRYPHON™ cradle within 10 seconds. The reader will beep indicating the configuration has been copied. The configuration will be simultaneously sent over the RS232 interface of the OM-GRYPHON™. If this causes undesired effects disconnect the RS232 cable between the PC and OM-GRYPHON™ during this process.

Copy Configuration i i i

;; ;; ;;

k k k

$+ZZ0$With the slave GRYPHON M, read the Get Configuration barcode below. Then place it onto the same OM-GRYPHON™ cradle used in the step above. The slave reader's address will not be changed. Get Configuration i i i

$+ZZ2$The configuration will be copied from the master to the slave GRYPHON M. The slave GRYPHON M signals the end of the procedure with a series of beeps. It is now ready to be used with its own OM-GRYPHON™ cradle. Repeat the procedure above to configure other slave readers. The OM-GRYPHON™ can continue to configure slave readers until it receives another command or data.

144

Page 155

TECHNICAL FEATURES

5.9.3

5

Copy OM-GRYPHON™

Procedure: Using the slave reader and its OM-GRYPHON™ cradle, read the Restore Default barcode, set the radio address, and then read the RS232 interface barcode from chapter 4 of this manual or from the Quick Reference Manual. Connect the master OM-GRYPHON™ and the slave OM-GRYPHON™ (cradle to be configured) together through two RS232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection. RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328 Power Supply: PG12 Read the Configuration Copy barcode below with a reader. Then place it onto the master OM-GRYPHON™ cradle. Copy Configuration i i i

;; ;; ;;

$+ZZ3$The configuration will be copied from the master OM-GRYPHON™ to the slave OM-GRYPHON™. The reader signals the end of the procedure with a series of beeps. Repeat the procedure above to configure other slave cradles.

Note: The master OM-GRYPHON™ can be configured for any interface.

145

Page 156

GRYPHON™

5

5.10 C-GRYPHON™ CONFIGURATION Battery selection is required only when the GRYPHON™ M reader has an Alkaline battery and you want to use C-GRYPHON™ either for serial configuration, software upgrades or to hold GRYPHON™ M. Since this type of battery must not be charged it is necessary to disable the C-GRYPHON™ charge function by following the procedure:

1.

With the GRYPHON™ M read the following code: Alkaline i i i

The green LED on the GRYPHON™ M will blink, signaling the reader has accepted the command.

2.

Place the reader onto the charger within 10 seconds. The green LED turns off and a short beep is emitted

To enable the charge function repeat step 1 and 2 substituting the "Alkaline" code with the following one: NiMh/NiCd i i i

Attempts to charge Alkaline batteries could cause leakage of liquid, generation of heat or, in extreme cases, explosion. If using Alkaline batteries, carefully follow the procedure above to avoid damage. CAUTION

146

Page 157

TECHNICAL FEATURES

5

5.11 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS232 and Data Format parameters for POS terminals are listed in the following table: NIXDORF Mode A

FUJITSU

ICL Mode

9600 Odd 8 1 Hardware (RTS/CTS) Disabled Enabled Disabled 9.9 sec Disabled

9600 None 8 1 None Disabled Enabled Disabled 2 sec Disabled

9600 Even 8 1 RTS always ON Disabled Enabled Disabled 9.9 sec Disabled

Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled

Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled

Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled

RS232 Group Baud Rate Parity Data Bits Stop Bits Handshaking ACK/NACK Protocol FIFO Inter-Character Delay RX Timeout Serial Trigger Lock

Data Format Group Code Identifier Header Terminator Field Adjustment Code Length TX Character Replacement Address Stamping Address Delimiter

The table below lists all the Code Identifiers available for the POS terminals: CODE UPC-A UPC-E EAN-8 EAN-13 Code 39 Codabar Code 128 Interleaved 2 of 5 Code 93 Industrial 2 of 5 UCC/EAN 128 MSI/Plessey RSS PDF417 Other

NIXDORF Mode A

FUJITSU

ICL Mode

A0 C B A M N K I L H P O E Q None

A E FF F None None None None None None None None None None None

A E FF F C [code length] N [code length] L [code length] I [code length] None H [code length] L [code length] None None None None

147