Page 138

GRYPHON™

5

5

REFERENCES

5.1

RS232 PARAMETERS

5.1.1

Handshaking

Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder before transmitting a character. Transmission is possible only if the CTS line (controlled by the Host) is active. Signals at EIA levels

RTS

TX Transmitted data

Transmitted data

Host busy

CTS

RTS/CTS handshaking

Software handshaking: (XON/XOFF) During transmission, if the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received. Transmitted data

Transmitted data

TX

RX XOFF Host busy

XON Host ready

XON/XOFF handshaking

128

Page 139

REFERENCES

5.1.2

5

ACK/NACK Protocol

GRYPHON™ D Readers This parameter sets a transmission protocol in which the Host responds to the reader after every code transmitted. The Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting retransmission, in the case of bad reception. data Gryphon D cable

Host

ACK or NACK ACK/NACK enabled

If the reader does not receive an ACK or NACK, transmission is ended after the RX Timeout (see par. 5.1.4). Selection of the ACK/NACK protocol temporarily disables FIFO buffering see par. 5.1.3.

GRYPHON™ M Readers The transmission protocol takes place between reader, cradle and Host. The reader passes its data (code read) to the cradle which sends it to the Host. In the following descriptions the completed transmission is indicated by the Beeper Control for Radio Response parameter with its default setting to Normal, see par. 5.7.3. When ACK/NACK is disabled, there is no control from cradle to Host transmission, the reader responds with the good reception tone. data data GRYPHON M

OM-GRYPHON™ cable

Host good RX beep

ACK/NACK disabled

129

Page 140

GRYPHON™

5 data data cable GRYPHON M good RX beep

OM-GRYPHON™

NACK

Host data ACK

ACK/NACK enabled

When ACK/NACK is enabled, the Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. Only after the ACK character is received by the OMGRYPHON™ does the reader respond with the good reception tone. If the reader does not receive an ACK or NACK, transmission is ended after the RX Timeout (see par. 5.1.4). See also Radio Protocol Timeout, par. 5.7.1 for M-Series readers. Selection of the ACK/NACK protocol temporarily disables FIFO buffering see par. 5.1.3.

5.1.3

FIFO

GRYPHON™ D Readers This parameter determines whether data (barcodes) are buffered on a First In First Out basis allowing faster data collection in certain cases for example when using slow baud rates and/or hardware handshaking. If the FIFO buffering is enabled, codes are collected and sent out on the serial line in the order of acquisition. About 800 characters can be collected (buffer full), after which the reader signals an error and discards any further codes until the transmission is restored. If the FIFO buffering is disabled, each code must be transmitted before another one can be read.

GRYPHON™ M Readers If enabled, the OM-GRYPHON™ collects all messages sent by GRYPHON™ M and sends them in order of acquisition to the connected Host. If disabled, GRYPHON™ M blocks message transmission until the OM-GRYPHON™ has completed transmission towards the Host.

130

Page 141

REFERENCES

5.1.4

5

RX Timeout

When the RS232 interface is selected, the Host can be used to configure the device by sending it command strings (see appendix A). This parameter can be used to automatically end data reception from the Host after the specified period of time. If no character is received from the Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer.

5.2 5.2.1

PEN PARAMETERS Minimum Output Pulse

This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode. In this way the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code read. The shortest pulse (200 µs) corresponds to a high resolution code emulation and therefore a shorter transfer speed to the decoder (for decoders able to work on high resolution codes). Likewise, longer pulses correspond to low resolution code emulation and therefore a longer transfer time to the decoder.

5.2.2

Conversion to Code 39 and Code 128

GRYPHON™ D Series Readers When using these readers it is possible to convert all codes to Code 39. By disabling this option the decoded codes will be transmitted in their original format; except for the following codes which are ALWAYS converted into Code 39 format: MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, PDF417, RSS.

GRYPHON™ M Series Readers When using these readers it is possible to choose between converting the decoded codes into either Code 39 format or Code 128 format. It is not possible to disable conversion.

131

Page 142

GRYPHON™

5

5.2.3

Overflow

This parameter generates a white space before the first bar and after the last bar of the code. The selections are as follows: narrow medium wide

= space 10 times the minimum output pulse. = space 20 times the minimum output pulse. = space 30 times the minimum output pulse.

5.2.4

Output and Idle Levels

The following state diagrams describe the different output and idle level combinations for Pen emulation: idle bar

OUTPUT: Normal space

IDLE: Normal black white barcode output bar

OUTPUT: Normal idle IDLE: Inverted space black white barcode output space

OUTPUT: Inverted white idle bar

IDLE: Normal black barcode output OUTPUT: Inverted idle white space bar

IDLE: Inverted barcode output

Output and Idle Levels

132 black

Page 143

REFERENCES

5.2.5

5

Inter-Block Delay

For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The inter-block delay parameter allows setting a delay between each block sent to the Host.

5.3

DATA FORMAT

The system always provides gun to host data communication using the following message formatting: Output Message from GRYPHON™ D or GRYPHON™ M Stand Alone Towards Host [Header] [Gun_Addr] [Gun_Addr_delimiter] ] [Code ID] [Code Length] CODE [Terminator] [Items in square brackets are optional.]

Output Message from GRYPHON™ M STAR-System™ Towards Host [Header] [Code ID] [Code Length] CODE [Terminator] [Items in square brackets are optional.]

5.3.1

Header/Terminator Selection

The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection: RS232:

no header, terminator CR-LF

WEDGE:

no header, terminator ENTER

These default values are always restored through the reading of RS232 or WEDGE interface selection code, see chapter 2.

133

Page 144

GRYPHON™

5

For the WEDGE interface, the following extended keyboard values can also be configured: EXTENDED KEYBOARD TO HEX CONVERSION TABLE IBM AT IBM 3153 APPLE ADB

IBM XT

IBM 31xx, 32xx, 34xx, 37xx

Wyse Digital

HEX

KEY

KEY

KEY

KEY

83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Euro

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 ESC BACKSPACE HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Space

FIELD EXIT TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 ENTER RESET INSERT DELETE FIELD FIELD + ENTER (Paddle) PRINT

RETURN TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 UP DOWN LEFT RIGHT ESC CTRL (Right) Space

Space

For all readers using Wedge interface, all values from 9C to FE send the Space character.

134

Page 145

Enter configuration i i

5.3.2

Exit and Save Configuration k k

Set Custom Extended Header/Terminator Keys

The extended Header/Terminator keys for Wedge Interface users can be customized by defining them through a simple keyboard setting procedure. For example, the Numeric Keypad keys can be set for use as Headers or Terminators by substituting the default extended keys using this procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys. Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the reader, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Back space" to correct a wrong key entry. In this case the reader emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". Set Custom Extended Header/Terminator Keys i'#8k i'#8k i'#8k Read the code above. •

If the first 4 KEYS (Shift, Alt, Ctrl, and Backspace) are not available on your keyboard, you can only substitute them with keys not used, or substitute them with each other.

•

Keys 5 to 28 must be defined

Press the desired keys in the following order:

The reader signals the end of the procedure with 2 beeps indicating the keys have been registered.

135

Page 146

GRYPHON™

5 CUSTOM EXTENDED KEYBOARD SETTING TABLE Custom Order

HEX

KEY

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A

Shift Alt Ctrl Backspace

GRYPHON™ M Series Only When working with GRYPHON™ M series readers, the keyboard setup functioning is signaled by the LEDs on the OM-GRYPHON™ cradle. Each key stroke corresponds to a double blinking of the green LED. By pressing the Backspace key the red LED on the OM-GRYPHON™ cradle blinks, while the green LED stays on.

Do not place the reader onto the OM-GRYPHON™ cradle during this procedure. Otherwise, the battery charging will occur modifying the LEDs functioning.

CAUTION Once the procedure has been completed, the green LED turns off.

136

Page 147

TECHNICAL FEATURES

5.3.3

5

Address Stamping

It is possible to include the reader address in the message sent to the host. The reader Address Stamping parameter consists of a 4-digit number in the range 0000-1999. For message output format, refer to par. 5.3.

5.3.4

Address Delimiter

The Address Delimiter allows a character to be included to separate the reader Address stamping field from the next field in the message. Any character can be included in the hexadecimal range from 00 to FE. For message output format, refer to par. 5.3.

5.4

POWER SAVE

5.4.1

Sleep State

This mode allows the µP in the reader to enter a “Sleep” state for minimum power consumption. For D-series readers, this command is only valid when hardware trigger type is selected. Before entering Sleep mode, the following are verified: • • • no commands coming from Host no data being transmitted to Host Enter Sleep Timeout ended (see par. 5.4.2)

To exit Sleep mode press the trigger. Enabling the Sleep state implements Standby mode for CCD devices, see par. 5.4.3. For M-series readers, sleep state is entered immediately after reading a code and is not configurable. To exit Sleep mode press the trigger.

5.4.2

Enter Sleep Timeout

For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.