Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 21

Gryphon Reference Manual: A Host Configuration Strings

Pages 165 to 177 of 183, from Gryphon Reference Manual

The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic D100 and Datalogic M100

Page 165

HOST CONFIGURATION STRINGS

A

A

HOST CONFIGURATION STRINGS

In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires the RS232 interface. The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following:

$+

Command

$-

CR Carriage return character (0D Hex.) Exit and Save configuration

Character sequence in following tables Enter configuration environment

Example: Multiple command programming sequence: $+

BG1 BH0

AC410132

$-

CR

Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment

Each configuration parameter setting removes the condition previously active for that parameter.

NOTE

The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands.

155

Page 166

GRYPHON™

A SERIAL CONFIGURATION STRINGS ENTER/EXIT CONFIGURATION COMMANDS DESCRIPTION Enter Configuration Exit and Save Configuration Restore Default Transmit Software Release (not for PEN emulation) Transmit Device Configuration in ASCII (not for PEN emulation)

STRING $+ $$* $! $&

These commands do not require $-.

INTERFACE SELECTION DESCRIPTION RS232 Standard ICL Mode Fujitsu Nixdorf Mode A WEDGE for IBM AT for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard Keyboard Type for IBM Terminals 31xx, typewriter 32xx, 34xx, 37xx advanced for IBM XT for IBM Terminal 3153 for IBM PC Notebook for IBM SURE1 for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx for Apple ADB Bus PEN EMULATION

156

STRING CP0 CM0 CM1 CM2 CP500 CP501 CP502 FK0 FK1 CP503 CP504 CP505 CP506 CP507 CP508 CP509 CP510 CP511 CP514 CP512 CP513 CP6

Page 167

HOST CONFIGURATION STRINGS

A RS232

DESCRIPTION Baud rate

150 300 600 1200 2400 4800 9600 19200 38400 Parity none even odd Data bits 7 8 9 Stop bits 1 2 Handshaking disable RTS/CTS XON/XOFF RTS always On ACK/NACK Protocol disable enable FIFO disable enable Inter-character delay (ms) RX Timeout (100 ms) Serial Trigger Lock disable (D series only) enable and select characters

STRING CD0 CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 CA2 CB0 CB1 CE0 CE1 CE2 CE3 CF0 CF3 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab a = Hex values representing an ASCII character from 00 to FE enabling the device trigger. b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.

157

Page 168

GRYPHON™

A USB DESCRIPTION USB-COM Handshaking

ACK/NACK Protocol FIFO Inter-character delay (ms) RX Timeout (100 ms) Serial Trigger Lock

USB-KBD Keyboard nationality (not for USB-KBD-ALT-MODE)

Delays Control Character Emulation

STRING disable RTS/CTS XON/XOFF RTS always ON disable enable disable enable disable enable

CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab

Belgian English French German Italian Spanish Swedish USA Japanese Inter-Character (ms) Inter-Code (s) CTRL +Shift + Key Ctrl + Key

FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 CK00 - CK99 FG00 - FG99 FO0 FO1 a = Hex values representing an ASCII character from 00 to FE enabling the device trigger. b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.

158

Page 169

HOST CONFIGURATION STRINGS

A WEDGE

DESCRIPTION Keyboard nationality

Caps Lock Caps Lock Auto-Recognition (IBM AT compatible only) Num Lock Delays Control Character Emulation

Belgian English French German Italian Spanish Swedish USA Japanese (IBM AT compatible only) caps Lock ON caps Lock OFF disable enable Toggle Num Lock Num Lock Unchanged Inter-Character (ms) Inter-Code (s) Ctrl + Shift + Key Ctrl + Key

STRING FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FE1 FE0 FP0 FP1 FL1 FL0 CK00 - CK99 FG00 - FG99 FO0 FO1

PEN DESCRIPTION Operating mode interpret (does not require $+ or $-) transparent (does not require $+ or $-) Minimum output pulse 200µs 400µs 600µs 800µs 1 ms 1.2 ms Conversion to Code 39 and disable conversion to Code 39 Code 128 (D series only) enable conversion to Code 39 enable conversion to Code 128 (M series only) Output level normal inverted Idle level normal inverted Overflow narrow overflow medium overflow wide overflow Inter-Block delay (100 ms)

STRING $] $[ DG0 DG1 DG2 DG3 DG4 DG5 DA0 DA1 DA2 DD0 DD1 DE0 DE1 DH0 DH1 DH2 CK00-CK99

159

Page 170

GRYPHON™

A DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Identifier disable Datalogic standard AIM standard Custom

Custom Code Identifier Headers

Terminators no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters five characters six characters seven characters eight characters

STRING EB0 EB1 EB2 EB3 EHabc EA00 EA01x EA02xx EA03xxx EA04xxxx EA05xxxxx EA06xxxxxx EA07xxxxxxx EA08xxxxxxxx EA10 EA11x EA12xx EA13xxx EA14xxxx EA15xxxxx EA16xxxxxx EA17xxxxxxx EA18xxxxxxxx a = ASCII character. b, c, x = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 58. b = Hex value of the first Custom Code Identifier character from 00 to FD; FF = disable Code Identifier c = Hex value of the second Custom Code Identifier character from 00 to FD; FF = disable second character of Custom Code Identifier x = Hex value from 00 to FE

160

Page 171

HOST CONFIGURATION STRINGS

A

DATA FORMAT (continued) NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Length Tx

Field Adjustment

Field Adjustment Character Character Replacement

Address Stamping Address Delimiter not transmitted transmitted in variable-digit format transmitted in fixed 4-digit format disable right addition left addition right deletion left deletion disable character replacement first character replacement second character replacement third character replacement disable reader address stamping enable reader address stamping disable reader address delimiter enable reader address delimiter and select character

STRING EE0 EE1 EE2 EF0 EFa0d EFa1d EFa2d EFa3d EGe EO0 EO1afg EO2afg EO3afg RU0 RU1 RV0 RV1h a = ASCII character. d = a number from the Hex/Numeric Table e, f, g, h = HEX values representing an ASCII character a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 58. d = a number in the range 01-32 from the Hex/Numeric Table e = Hex value from 00 to FE f = Hex value of the character to be replaced from 00 to FE g = Hex value of the new character to insert from 00 to FE FF = replace with no new character (remove character) h = a HEX value in the range from 00 - FE representing the ASCII character.

POWER SAVE DESCRIPTION Scan Rate

Sleep State Enter Sleep Timeout (100 ms) Standby

67 scans per sec. 135 scans per sec. 270 scans per sec. disable enable enable disable

STRING BT0 BT1 BT2 BQ0 BQ1 BR00-BR99 BM0 BM1

161

Page 172

GRYPHON™

A READING PARAMETERS DESCRIPTION Operating Mode

Hand-Held Operation

Stand Operation

Hardware Trigger Mode Trigger-off Timeout (s) FLASH ON (100 ms) FLASH OFF (100 ms) Reads per Cycle Safety Time (100 ms) Beeper Intensity

Beeper Tone

Beeper Type Beeper Length PDF Decoding Recognition Intensity Good Read Spot - Duration

162 hand-held operation stand operation automatic software trigger hardware trigger automatic always on hardware trigger ready software trigger hardware trigger automatic always on trigger active level trigger active pulse one read multiple reads very low intensity low intensity medium intensity high intensity tone 1 tone 2 tone 3 tone 4 monotone bitonal long short low high disabled short medium long

STRING BP0 BP1 BP2 BK0 BK1 BK2 BK3 BK4 BU1 BU3 BU0 BU2 BA0 BA1 BD00 - BD99 BB001 - BB099 BB101 - BB199 BC0 BC1 BE00 - BE99 BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 BJ0 BJ1 BI0 BI1 BW0 BW1 BV0 BV1 BV2 BV3

Page 173

HOST CONFIGURATION STRINGS

A

DECODING PARAMETERS DESCRIPTION Ink-spread Overflow control Interdigit control Puzzle SolverTM Decoding Safety disable enable disable enable disable enable disable enable one read two reads three reads four reads

CODE SELECTION DESCRIPTION DISABLE ALL FAMILY CODES EAN/UPC disable EAN/UPC family EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON with and without ADD ON EAN 8/EAN 13 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 UPC A/UPC E without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 EAN 8 check digit transmission disable enable EAN 13 check digit transmission disable enable UPC A check digit transmission disable enable UPC E check digit transmission disable enable conversions UPC E to UPC A UPC E to EAN 13 UPC A to EAN 13 EAN 8 to EAN 13

STRING AX0 AX1 AW1 AW0 AV0 AV1 AU0 AU1 ED0 ED1 ED2 ED3

STRING AZ0 AA0 AA1 AA5 AA8 AA3 AAK AAL AA6 AA4 AAM AAN AA7 AAG0 AAG1 AAH0 AAH1 AAI0 AAI1 AAJ0 AAJ1 AAA AAB AAC AAD

163

Page 174

A CODE SELECTION (continued) DESCRIPTION ISBN Conversion codes enable ISBN enable ISSN enable ISBN and ISSN disable ISBN and ISSN Code 39 disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP 39 Code 32 code length 2/5 disable Code 2/5 family Interleaved 2/5 no check digit control check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control check digit control and transmission check digit control without transmission CIP/HR xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters:

Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

164

GRYPHON™

STRING AP1 AP2 AP3 AP0 AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5

Page 175

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION Codabar disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC Codabar no start/stop character equality control but transmission Codabar ABC forced concatenation code length start/stop character case in transmission lower case upper case Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit Transmit GS before disable Code enable ISBT 128 enable ISBT 128 code length Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit

A

STRING AD0 AD111 AD112 AD121 AD122 AD212 AD232 AD*xxxx ADA0 ADA1 AI0 AI11 AI21 EQ0 EQ1 AI31 AILxxxx AK0 AK1 xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters:

EXAMPLES: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

CODE SELECTION (continued) DESCRIPTION MSI disable the family no check MOD10 no tx MOD10 with tx MOD11-MOD10 no tx MOD11-MOD10 with tx MOD10-MOD10 no tx MOD10-MOD10 with tx

STRING AE0 AE1 AE2 AE3 AE4 AE5 AE6 AE7

165

Page 176

GRYPHON™

A CODE SELECTION (continued) DESCRIPTION

STRING

Plessey disable the family Standard no check Standard check - with tx Standard check - no tx Anker no check Anker check - with tx Anker check - no tx

AF0 AF11 AF12 AF13 AF21 AF22 AF23

Telepen disable the family Numeric no check Numeric check - with tx Numeric check - no tx Alpha no check Alpha check - with tx Alpha check - no tx disable the family no check Type 1 check Type 2 check disable the family no check Type C with tx Type C no tx Type K with tx Type K no tx Type C and K with tx Type C and K no tx disable enable disable enable disable enable disable the family disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked

AL0 AL11 AL12 AL13 AL21 AL22 AL23 AH0 AH1 AH2 AH3 AG0 AG1 AG21 AG22 AG31 AG32 AG41 AG42 AJ0 AJ1 AM0 AM1 AR0 AR1 AQ0 AQ10 AQ11 AQ20 AQ21 AQ30 AQ31

Delta IBM

Code 11

Code 16K Code 49 PDF417 RSS Codes

166

Page 177

HOST CONFIGURATION STRINGS

RADIO PARAMETERS DESCRIPTION Radio Protocol Timeout enable (seconds) Power-Off Timeout Beeper Control For Radio Response normal only good decode only good reception off Battery Type alkaline NiMh Single Store disable one attempt two attempts three attempts four attempts five attempts six attempts seven attempts eight attempts nine attempts

A

STRING RH02-RH19 RP00-RP99 BF0 BF1 BF2 BF3 RB0 RB1 RO0 RO1 RO2 RO3 RO4 RO5 RO6 RO7 RO8 RO9

167