For the Datalogic CM52
Page 11
Remote I/O Connector The CM52 RIO connector is a female three-pin screw-terminal connector that is the standard Remote I/O connector. Nodes are linked by daisy-chaining two signal wires and a shield conductor from these connectors. Typically the blue wire is Pin 1 and the clear wire is Pin 3 with the shield in the center on Pin 2. On the CM52, this connector is externally accessible. Table 1, Remote I/O Pinouts
Terminal
Description
1
Line 1 - Blue wire (+)
2
Shield
3
Line 2 - Clear wire (-)
COM1 Connector The DB9 connector simplifies the connection of a host to the COM1 serial interface. The pinouts are standard and provided in Table 2 for your convenience. Signal names are relative to the CM52.
Table 2, COM1 Pinouts
Pin
Description
2
RS232 TX
3
RS232 RX
5
Signal Ground
All other pins are no connects.
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
5
Page 12
Internal Connections To access the internal connectors, switches, and jumpers, first turn off power to the module. Next, loosen the two thumbscrews which hold the cover tot he base plate, Then remove the cover. Observe standard ESD procedures to protect circuits from damage. All connections are made to screw-type terminal blocks with cable clamps provided to physically retain the cabling. Figure 4 shows terminal block and the signal designations.
Figure 4, CM52 Internal Connector
6
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 13
2.3 Cables Use 1770-CD (Belden 9463) cable and connect a Remote I/O network using a daisy chain or trunk line/drop line configuration. For daisy chain configurations, use the following table to determine the total cable length you can use. Table 3, Cable Lengths
Communication Rate
Length
57.6 kbps
3,048 m (10,000 ft)
115.2 kbps
1,524 m (5,000 ft)
230.4 kbps
762 m (2,500 ft)
2.4 Bus Termination For proper operation terminate both ends of the Remote I/O link by placing an external resistor across the two signal wires at the three-pin connectors. Table 4 shows the proper resistor value that should be used for a particular RIO link configuration.
Table 4, Remote I/O Pinouts
Maximum Number of Remote I/O Link Configuration
Resistor Rating
Devices on the Link
Operating at 230.4 kbps
82 ohms
32
Operating at 57.6 kbps or 115.2 kbps and no de-
82 ohms
32
150 ohms
16
150 ohms
16 vices requiring 150 ohm resistors are on the link Devices requiring 150 ohm resistors are on the link Operating at 57.6 kbps or 115.2 kbps and link does not need to support more than 16 devices
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
7
Page 14
2.5 Internal Switches and Jumpers To access the internal switches and jumpers remove power from the module. Next, loosen the screws that hold the cover to the body, then remove the cover. Observe standard ESD procedures to protect circuits from damage.
Figure 5, CM52 DIP Switches
User-configurable RIO bus parameters are set with bit switches on the RIO interface board (the top board of the two-board CM52 stack). There are three banks of bit switches with definitions as follows: Switch
8
7
6
5
4
3
2 reserved
Rack Size reserved
Last Rack Baud Rate
1
Bank SW1
Rack Address
SW2
Display reserved
Starting Quarter
Banner SW3
8 reserved
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 15
Details of each field setting are given in the sections below. Switch numbers and the meaning of each possible combination are shown. Note that ON and Off correspond to the labeled ON and OFF position on the switches themselves. Rack Address Switch Settings Table 5 shows the switch configuration for all possible Rack Addresses from 0 to 59. Shaded areas indicate switches in the OFF position. Table 5, Switch Settings for RIO Address
Rack
SW1 DIP Switches
Rack
Address Dec HEX
SW1 DIP Switches
Address 8
7
6
5
4
0
00
1
01
2
02
3
03
4
04
ON
5
05
ON
6
06
ON
ON
7
07
ON
ON
8
08
ON
3
Dec HEX 30
ON ON ON
ON
ON
9
09
ON
10
0A
ON
11
0B
ON
12
0C
ON
13
0D
ON
ON
14
0E
ON
ON
ON
ON
ON
ON
ON
ON ON ON
ON
ON ON
15
0F
16
10
ON
17
11
ON
18
12
ON
19
13
ON
20
14
ON
ON
21
15
ON
ON
22
16
ON
ON
ON
23
17
ON
ON
ON
24
18
ON
ON
25
19
ON
ON
26
1A
ON
ON
27
1B
ON
ON
28
1C
ON
ON
ON
29
1D
ON
ON
ON
ON
ON ON ON
ON
ON
ON
ON ON ON
ON
ON
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
8
1E
7
6
5
4
ON
ON
ON
ON
ON
ON
ON
ON
31
1F
32
20
ON
33
21
ON
34
22
ON
35
23
ON
36
24
ON
ON
37
25
ON
ON
38
26
ON
ON
ON
39
27
ON
ON
ON
40
28
ON
ON
3
ON
ON ON ON
41
29
ON
ON
42
2A
ON
ON
ON
ON
ON
ON ON
43
2B
ON
ON
44
2C
ON
ON
ON
ON
45
2D
ON
ON
ON
46
2E
ON
ON
ON
ON
ON
ON
ON
ON
ON
47
2F
ON
48
30
ON
ON
49
31
ON
ON
50
32
ON
ON
51
33
ON
ON
52
34
ON
ON
ON
53
35
ON
ON
ON
54
36
ON
ON
ON
ON
55
37
ON
ON
ON
ON
56
38
ON
ON
ON
ON
ON ON ON
ON
ON
57
39
ON
ON
ON
58
3A
ON
ON
ON
ON
59
3B
ON
ON
ON
ON
ON
ON
ON
9
Page 16
Starting Quarter Switch Settings The group address is determined by selecting a starting rack quarter for the CM52. Note that if the CM52 is configured as a half-rack device it cannot start at the fourth quarter. In such a case, if the fourth quarter is selected, the CM52 will change the starting quarter internally to the third quarter and print an error message to COM1 at startup (if the Display Banner bit switch is ON). Table 6, Starting Quarter Switch Settings
SW1 DIP Switch Settings Starting Quarter
Group Number
2
1
First Quarter
Group 0
OFF
OFF
Second Quarter
Group 2
OFF
ON
Third Quarter
Group 4
ON
OFF
Fourth Quarter
Group 6
ON
ON
Baud Rate Switch Settings One of three baud rates is selectable. Note that if switch 2 is ON, switch 1 is ignored. Table 7, Baud Rate Switch Settings
SW2 DIP Switch Settings Baud Rate
2
1
57.6 Kbits/sec
OFF
OFF
115.2 Kbits/sec
OFF
ON
230.4 Kbits/sec
ON
OFF
10
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 17
Last Rack Switch Settings In a PLC-2 system, this switch should be ON if the CM52 is the highest group in its rack address. Table 8, Last Rack DIP Switch
Last Rack (SW2)
DIP Switch 3
CM52 is not the highest group in this rack address
OFF
CM52 is the highest group in this rack address
ON
Rack Size Switch Settings The Rack Size switch configures the CM52 as a 1/4 rack or 1/2 rack device. Table 9, Rack Size DIP Switch
Rack Size (SW2)
DIP Switch 5
Quarter Rack
OFF
Half Rack
ON
Display Banner Switch Setting The Display Banner switch enables or disables transmission of the startup banner when the CM52 is powered-up or reset. If the switch is OFF nothing is printed on COM1. If the switch is ON various CM52 configuration information is printed including the version number for internal software modules, the RIO baud rate and address settings and any configuration errors or warnings that occur at startup.
Table 10, Display Banner DIP Switch
Display Banner (SW2)
DIP Switch 8
No Banner Display
OFF
Banner Display
ON
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
11
Page 18
Default Settings The CM52 is shipped with all switches in the off position with the resulting configuration: Rack Address 0 Group Address 0 Baud Rate 57.6 Kbps Last Rack NO Rack Size Quarter Rack Banner Display None
2.6 Jumpers There are two selectable jumpers (J7 and J12) located on the CM52 Controller Board as illustrated below in Figure 6.
Pin 1
Pin 9
Pin 1
Pin 4
Figure 6, CM52 Controller Board Jumpers
12
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 19
J7, COM2 RS232/RS485/RS422 Selection Jumper J7 on the Controller board selects the serial communication protocol. The default setting configures the CM52 for communication with devices supporting RS232 protocol. For RS485/MUX 32 or RS422 protocol configure J7 as shown below in Figure 7.
Figure 7, Jumper Settings
NOTE: For proper serial port communications, all of the following items must be properly configured: Jumpers Serial Parameters Output pin or terminal connections J12, Run/Re-program Reset This jumper is used to re-program and test the CM52. You will not need to change the settings of this jumper if you are using the Standard Program. If you wish to modify the Standard Program, contact your Escort Memory Systems representative for assistance.
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
13
Page 20
2.7 LED Indicators The CM52 has six LED indicators on the front panel as shown in Figure 8.
Figure 8, CM52 LED Indicators
The LEDs colors and meanings are explained in Table 11 below. Table 11, CM52 LED Indicators
LED
Color
Indicates
Power
Green
The CM52 has power
Bus Active
Green
There is activity in the bus. See below for explanation.
ANT O
Red
Antenna port 0 is active
ANT 1
Red
Antenna port 1 is active
COM1
Green
Serial communications port 1 is active
COM2
Green
Serial communications port 2 is active
14
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module