CM52 Remote I/O Interface Module Operator's Manual, pages 1 to 10

Pages 1 to 10 of 116

The original document is the PDF (886 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic CM52

Page 1 read from a scan by OCR; it may hold reading errors

OPERATOR'S MANUAL

CM52 Remote 1/0 Interface Module

Manual Revision 2, 8-98 | .

Publication #17-1262

Wr,

Page 2

Escort Memory Systems Warranty Escort Memory Systems warrants that all products of its own manufacture conform to Escort Memory Systems specifications and are free from defects in material and workmanship when used under normal operating conditions and within the service conditions for which they were furnished. The obligation of Escort Memory Systems hereunder shall expire one (1) year after delivery, unless otherwise specified, and is limited to repairing, or at its option, replacing without charge, any such product which in Escort Memory Systems’ sole opinion proves to be defective within the scope of this Warranty. In the event Escort Memory Systems is not able to repair or replace defective products or components within a reasonable time after receipt thereof, Buyers shall be credited for their value at the original purchase price. Escort Memory Systems must be notified in writing of the defect or nonconformity within the warranty period and the affected product returned to Escort Memory Systems factory or to an authorized service center within thirty (30) days after discovery of such defect or nonconformity. Shipment shall not be made without prior authorization by Escort Memory Systems. This is Escort Memory Systems’ sole warranty with respect to the products delivered hereunder. No statement, representation, agreement or understanding oral or written, made by an agent, distributor, representative, or employee of Escort Memory Systems which is not contained in this warranty, will be binding upon Escort Memory Systems, unless made in writing and executed by an authorized Escort Memory Systems employee. Escort Memory Systems makes no other warranty of any kind whatsoever, expressed or implied, and all implied warranties of merchantability and fitness for a particular use which exceed the aforestated obligation are hereby disclaimed by Escort Memory Systems and excluded from this agreement.

Under no circumstances shall

Escort Memory Systems be liable to Buyer, in contract or in tort, for any special, indirect, incidental, or consequential damages, expenses, losses or delay however caused. Equipment or parts which have been subject to abuse, misuse, accident, alteration, neglect, unauthorized repair or installation are not covered by warranty. Escort Memory Systems shall make the final determination as to the existence and cause of any alleged defect.

No liability is assumed for expendable items such as lamps and fuses.

No warranty is made with respect to custom equipment or products produced to Buyer’s specifications except as specifically stated in writing by Escort Memory Systems in the contract for such custom equipment. This warranty is the only warranty made by Escort Memory Systems with respect to the goods delivered hereunder, and may be modified or amended only by a written instrument signed by a duly authorized officer of Escort Memory Systems and accepted by the Buyer.

This document contains proprietary information which is protected by copyright. All rights are reserved. The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. EMS®, Escort Memory Systems® and the EMS® logo are registered trademarks of Escort Memory Systems, a Datalogic Group Company Other brand and product names mentioned are trademarks or registered trademarks of their respective holders. Escort Memory Systems, Inc. A Datalogic Group Company

3 Victor Square Scotts Valley, CA 95066 Telephone (831) 438-7000 FAX (831) 438-5768 www.ems-rfid.com ii

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 3

TABLE OF CONTENTS 1

INTRODUCTION 1.1

2

2.3 2.4 2.5

2.6

2.7

3

CM52 Description . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION 2.1 2.2

3.2

3

Mechanical Dimensions . . . . . . . . . . . . . . . . . . 3 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connector Panel . . . . . . . . . . . . . . . . . . . . . . 4 Remote I/O Connector . . . . . . . . . . . . . . . . . . . 5 COM1 Connector . . . . . . . . . . . . . . . . . . . . . 5 Internal Connections . . . . . . . . . . . . . . . . . . . 6 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Bus Termination . . . . . . . . . . . . . . . . . . . . . . 7 Internal Switches and Jumpers . . . . . . . . . . . . . . 8 Rack Address Switch Settings . . . . . . . . . . . . . . . 9 Starting Quarter Switch Settings . . . . . . . . . . . . 10 Last Rack Switch Settings . . . . . . . . . . . . . . . . 11 Rack Size Switch Settings . . . . . . . . . . . . . . . . 11 Display Banner Switch Setting . . . . . . . . . . . . . 11 Default Settings . . . . . . . . . . . . . . . . . . . . . 12 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . 12 J7, COM2 RS232/RS485/RS422 Selection . . . . . . 13 J12, Run/Re-program Reset . . . . . . . . . . . . . . 13 LED Indicators . . . . . . . . . . . . . . . . . . . . . 14 Bus Active LED . . . . . . . . . . . . . . . . . . . . . 15 Possible Causes of Frequent Bus Retries . . . . . . . . 15

REMOTE I/O INTERFACE 3.1

1

16

Overview . . . . . . . . . . . . . . . . . . . . . . . . . 16 Device Addressing . . . . . . . . . . . . . . . . . . . . 17 Data Transfer . . . . . . . . . . . . . . . . . . . . . . . 19 Command and Response Structure . . . . . . . . . . . 19 Command and Response Flags (Discrete Data) . . . . 20 Command Flags (Discrete Data) . . . . . . . . . . . . 20 Initiate Bit . . . . . . . . . . . . . . . . . . . . . . . . 20 Response Flags (Discrete Data) . . . . . . . . . . . . . 21 Acknowledge . . . . . . . . . . . . . . . . . . . . . . . 22 Done . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module iii

Page 4

3.3 3.4 3.5 3.6 iv

Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Error . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Digital Input . . . . . . . . . . . . . . . . . . . . . . . 23 Task Done . . . . . . . . . . . . . . . . . . . . . . . . 24 Data Ready . . . . . . . . . . . . . . . . . . . . . . . . 24 PLC Memory Mapping . . . . . . . . . . . . . . . . . 24 Command and Response Parameters (Block Data) . . . . . . . . . . . . . . . . . . . . . . . 27 Command Parameters . . . . . . . . . . . . . . . . . 27 Command Data Lengths . . . . . . . . . . . . . . . . 28 Block Transfer Problems . . . . . . . . . . . . . . . . 29 Command Protocol . . . . . . . . . . . . . . . . . . . 30 Posted Commands . . . . . . . . . . . . . . . . . . . . 32 Command Descriptions . . . . . . . . . . . . . . . . . 32 Initialization Commands . . . . . . . . . . . . . . . . 34 Define Mode, Opcode 120 . . . . . . . . . . . . . . 34 Define Serial Parameters, Opcode 10 . . . . . . . . 37 Antenna Port Commands . . . . . . . . . . . . . . . . 39 HS Tag Fill, Opcode 4 . . . . . . . . . . . . . . . . 39 HS Tag Read, Opcode 5 . . . . . . . . . . . . . . . 41 HS Tag Write, Opcode 6 . . . . . . . . . . . . . . . 44 Reset Tag Battery Timer, Opcode 13 . . . . . . . . 46 Tag-to-Tag Transfer, Opcode 20 . . . . . . . . . . . 48 RS232 Serial Interface Commands . . . . . . . . . . . 50 General RS232 Commands . . . . . . . . . . . . . . . 50 Serial ReadLn, Opcode 9 . . . . . . . . . . . . . . . 50 Serial Read, Opcode 11 . . . . . . . . . . . . . . . . 53 Serial Write, Opcode 12 . . . . . . . . . . . . . . . . 55 Clear Serial Buffers, Opcode 14 . . . . . . . . . . . 57 HMS RS232 Commands . . . . . . . . . . . . . . . . 59 HMS Tag Fill (RS232), Opcode 16 . . . . . . . . . 59 HMS Tag Read (RS232), Opcode 17 . . . . . . . . . 61 HMS Tag Write (RS232), Opcode 18 . . . . . . . . 64 MUX32 Serial Interface Commands . . . . . . . . . . 66 General MUX32 Commands . . . . . . . . . . . . . . 66 MUX32 Read, Opcode 30 . . . . . . . . . . . . . . . 66 MUX32 Write, Opcode 31 . . . . . . . . . . . . . . 68 MUX32 Collect, Opcode 39 . . . . . . . . . . . . . 70 HMS MUX32 Commands . . . . . . . . . . . . . . . . 72 HMS MUX32 Tag Read, Opcode 32 . . . . . . . . 72

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 5

HMS MUX32 Tag Write, Opcode 33 . . . . . . . . 74 HMS MUX32 Tag Fill, Opcode 34 . . . . . . . . . 76 General Auto-Polled MUX32 Commands . . . . . . . 78 MUX32 Read (Auto-polled), Opcode 40 . . . . . . . 79 MUX32 Write (Auto-Polled), Opcode 41 . . . . . . 82 HMS Auto-Polled MUX32 Commands . . . . . . . . 84 HMS MUX32 Tag Read (Auto-Polled), Opcode 42 84 HMS MUX32 Tag Write (Auto-Polled), Opcode 43 86 HMS MUX32 Tag Fill (Auto-polled), Opcode 44 . 88 Posted Commands . . . . . . . . . . . . . . . . . . . . 90 Read Commands . . . . . . . . . . . . . . . . . . . . . 90 Write Commands . . . . . . . . . . . . . . . . . . . . 91 Post Tag Read, Opcode 60 . . . . . . . . . . . . . . 92 Post Tag Write, Opcode 61 . . . . . . . . . . . . . . 94 Post Serial Read, Opcode 62 . . . . . . . . . . . . . 96 Post Serial ReadLn, Opcode 63 . . . . . . . . . . . 98 Buffer Read, Opcode 68 . . . . . . . . . . . . . . . 100 Buffer Write, Opcode 69 . . . . . . . . . . . . . . 103

A

APPENDIX QUICK REFERENCE

105

B

APPENDIX SPECIFICATIONS

107

C

APPENDIX ASCII CHART

108

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module v

Page 6

vi

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 7

1 INTRODUCTION 1.1 CM52 Description The CM52 Remote I/O (RIO) module is a general purpose programmable interface between the Allen-Bradley (A-B) Remote I/O network and Escort Memory Systems’ RFID (Radio Frequency Identification) equipment, or third party products. The CM52 interfaces to a variety of devices: two EMS HS/HL500-Series antennas; two HMS8xx series antennas; two serial ports; and as many as 32 HMS-Series Reader/Writers, RS-Series Read Only antennas, or bar code scanners (or combinations) on an RS485 MUX32 line. The CM52 is housed in a NEMA 2 enclosure suitable for light-industrial and commercial applications, and is DIN rail mountable with optional clips (00-1096). The CM52 is a slave device that supports RIO protocol at communication speeds of 57.6K, 115.2K or 230.4K bits-per-second and is therefore compatible with all RIO scanners. This programmable interface is provided with a standard program that allows RIO commands to control the reading and writing of a block (or non-contiguous blocks) of data, MUX32 connection status, serial inputs and outputs, and fill functions. Custom application programs can be written and downloaded to the CM52. Please contact your Escort Memory Systems (EMS) representative for assistance if modification to the Standard Program is needed. Power for the CM52 is supplied by an external power supply. All device I/O is electrically isolated from the Remote I/O bus.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

1

Page 8

The CM52 is equipped with three microprocessors: The node adapter chip processor, to interface with the Remote I/O bus An RF coprocessor, to read and write tags. A powerful 386EX main processor to manage serial I/O and the RF commands To facilitate control, the main processor utilizes a real-time operating system. Using this approach, up to four tasks may execute concurrently. With a real-time operating system and separate coprocessors, it is possible to simultaneously write data on a serial port, read a tag, and handle bus traffic. Special commands have been implemented to improve throughput when reading large tags. The data on the tag is first read into a buffer on the CM52. Subsequent commands transfer the data in the buffer, across the bus, to the host. A 16K buffer is available to hold the data for each task. The CM52 has several possible RFID configurations. It may be connected to two HS-Series Antennas through its antenna ports or to HMSSeries Passive Reader/Writers or RS Series Read Only devices via the serial ports. The CM52 can transfer 3000 bytes per second to or from HS-Series tags. Using the long range tags HS tags, the distance from the antenna to the tag can be 20 inches.

2

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 9

2 INSTALLATION 2.1 Mechanical Dimensions Below are the mechanical dimensions of the CM52 and the optional DIN rail clips.

Figure 1, CM52 Dimensions

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

3

Page 10

Figure 2, CM52 DIN Rail Clip

2.2 Connectors Connector Panel Only the Remote I/O connector and a standard DB9 connector for COM1 are mounted externally. All other connections are made on the terminal strip connector inside the CM52 and accessed through the cable grips.

Figure 3, CM52 Connector Panel

4

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module