Page 17
Chapter 2
General Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). START/END DURATION
BAR CODE
0.1 Second
0.2 Second
0.3 Second
0.4 Second
Product Reference Guide
2-1
Page 18
General Features
Double Read Timeout, continued START/END DURATION
BAR CODE
0.5 Second
0.6 Second
0.7 Second
0.8 Second
0.9 Second
1 Second
2-2
PowerScan® 7000BT SRI
Page 19
Powerdown Timeout
Powerdown Timeout The Powerdown Timeout feature sets the time for automatically switching the scanner off when it is not in use. START/END DURATION
BAR CODE
Disable
15 Seconds
30 Seconds
5 Minutes
Product Reference Guide
2-3
Page 20
General Features START/END DURATION
BAR CODE
15 Minutes
30 Minutes
1 Hour
2-4
PowerScan® 7000BT SRI
Page 21
LED and Beeper Indicators
LED and Beeper Indicators The features provided in this section concern general system LED and Beeper indications. For indication features specific to radio frequency, see the Bluetooth Features section of this manual.
Power On Alert Disables or enables the indication (from the Beeper) that the scanner is receiving power. START/END STATE
BAR CODE
Disable
Enable
Product Reference Guide
2-5
Page 22
General Features
LED Idle State Specifies state of scanner’s LED when the scanner is ready to read a bar code. START STATE
BAR CODE
Disable
Enable
END
2-6
PowerScan® 7000BT SRI
Page 23
LED and Beeper Indicators
Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: •
Good Read = Indicate after decode
•
Good Read = Indicate after transmit
•
Good Read = Indicate after CTS goes inactive, then active This option, which uses CTS, is only valid for RS-232 interfaces. NOTE
START/END INDICATE
BAR CODE
After decode
After transmit
After CTS goes inactive, then active
Product Reference Guide
2-7
Page 24
General Features
Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code. START/END STATE
BAR CODE
Disable
Enable
2-8
PowerScan® 7000BT SRI
Page 25
LED and Beeper Indicators
Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/ tone.) START/END FREQUENCY
BAR CODE
Low
Medium
High
Product Reference Guide
2-9