Page 9
Chapter 1
Getting Started The PowerScan® 7000BT SRI Linear Imager uses Bluetooth® wireless technology1 for communications between the handheld scanner and Base Station (or PC). The scanner and Base station operate on a master/ slave system, with the Base station acting as the master and the scanner as the slave. The handheld itself marks a new performance level in bar code scanning. It delivers aggressive read rates and depths of field on 1D and stacked codes. This aggressiveness applies even in challenging reading environments where low lighting conditions and poor quality might make it difficult to read bar codes. You can rest assured your investment will continue to supply years of use by reading any bar codes you require, now or in the future. Designed for today’s demanding commercial and industrial environments, the scanner offers superior image quality, speed, durability, and the ability to read poor quality bar codes. The unit is comfortable to hold, easy to use, rugged, and excellent for the most demanding applications.
1. The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc.
Product Reference Guide
1-1
Page 10
Getting Started
About This Manual This Product Reference Guide (PRG) provides programming instructions for the scanner, plus product specifications and dimensions. For installation, maintenance, troubleshooting and warranty information, see the Quick Reference Guide (QRG). Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual. The scanner is factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. Bold text and a yellow-highlighted background indicates the most common default setting for a feature/option.
Manual Conventions The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the scanner: Notes contain information necessary for properly diagnosing, repairing and operating the scanner. NOTE
The CAUTION symbol advises you of actions that could damage equipment or property. CAUTION
Connection Figure 1-1 shows how to connect the Base Station to a terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding.
1-2
PowerScan® 7000BT SRI
Page 11
About This Manual Base Station Connection and Routing, Fully insert the Power Cable and Interface (I/F) Cable connectors into their respective ports in the underside of the Base Station (see Figure 1-1). Alternatively, you can either loop the cables around the routing clips and back through the routing channel to the front of the Base Station as shown, or the cables can be fed directly out the back of the Base Station via the routing clips. Figure 1-1. Connecting the Base Station
Power Cable I/F Cable Routing Channel
Routing Clips Bottom of Base Station I/F Cable
AC Adapter
Base Station
Power Cable
Host Connection, The interface type was specified at the time your scanner was ordered, however you should verify before connection that the scanner’s cable type is compatible with your host equipment. Most connections plug directly into the host device as shown in Figure 1-2. Keyboard Wedge interface cables have a ‘Y’ connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal/PC.
Product Reference Guide
1-3
Page 12
Getting Started
B
Figure 1-2. Connecting to the Host or...
nd
Wa b ed oar ge d or...
M or...
K ey W
US
IB
Power Connection, Plug the AC Adapter in to an approved AC wall socket with the cable facing downwards (as shown in Figure 1-1) to prevent undue strain on the socket.
Linking the Scanner to a Base Station To link a scanner to a Base Station, press the Link Button (see Figure 1-3) on the Base Station for at least one second to place the base in "Link Mode," then scan the bar code below or the Link bar code located on the Base Station using the scanner to be linked. The Link bar code on the Base Station contains an identifier that is unique to that Base Station. This enables the scanner to quickly find and link to that Base Station.
1-4
PowerScan® 7000BT SRI
Page 13
Linking the Scanner to a Base Station
Linking the Scanner to a Base Station, cont. When the generic Link to Base Station label (shown below) is used for linking, you will notice that linking is slower and a rescan of the label may be required before a successful link is made. If two Base Stations are in the linking mode at the same time, the generic label will not be able to initiate a successful link, since the scanner will not know which Base Station it is supposed to link to. A successful link is indicated by three ascending tones from the scanner. A high-low-high-low tone indicates the link attempt was unsuccessful. A single green LED flash during this tone indicates no Base Station was discovered. Two green LED flashes during this tone indicates that more than one Base Station was discovered and the scanner did not link. Link to Base Station
Figure 1-3. Labeling and Nomenclature This illustration shows label placement ONLY. For actual regulatory, patent and other applicable information, view the labels on the product intself, or call your nearest sales or service office.
Antenna
Link Bar Code
Scanner Scan Window
Link Button Trigger Green LED Amber LED
S/N and Laser Safety Label
Indicator LEDs Speaker Port Battery Pack Battery Latch
Product Reference Guide
Scanner Latch
Base Station
1-5
Page 14
Getting Started
Optional: Linking the Scanner to a PC A scanner can optionally be linked to a Bluetooth-enabled PC with the serial port profile. To do this, follow these steps: 1. Ensure the PC or terminal can network with Bluetooth devices and that it is powered on. 2. Scan the “Link to a PC” bar code below.
Link to a PC
3. On the PC, scan for network devices. 4. Select the “Datalogic PS7000 Scanner1.” Make sure “Secure Connection” is disabled. 5. Select “connect” on the PC to link the scanner to the PC.
Paging Feature To help locate a missing scanner, press the Base Station Link Button momentarily (less than one second). This will cause the scanner to beep five times at its loudest volume setting.
1. Depending upon when your scanner was purchased, your selection may be 'PSC PS7000 Scanner.”
1-6
PowerScan® 7000BT SRI
Page 15
Programming
Programming This manual contains feature descriptions and bar codes which allow you to reconfigure your scanner. Some programming bar code labels, like the label below for resetting defaults, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the scanner to be placed in Programming Mode prior to scanning them. Unless instructed otherwise for feature configuration, scan a START/END bar code once to enterProgramming Mode. Once the scanner is in Programming Mode, you can scan a number of parameter settings before scanning the START/END bar code a second time, which will then accept your changes, exit Programming Mode and return the scanner to normal operation. The scanner is typically factory-configured with a set of default features standard to the interface type you ordered. After scanning the interface bar code from the Interface Related Features section, you can select other options and customize your scanner through use of the instructions and programming bar codes available in that section and also the Data Editing and Symbologies chapters of this manual.
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below. This will copy the factory configuration for the currently active interface to the current configuration.
Standard Product Default Settings
The programming section lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text) on the following pages.
Product Reference Guide
1-7
Page 16
Getting Started
NOTES