The text of a manual · part 4 of 31
PowerScan 7000BT SRI Linear Imager Product Reference Guide: General Features, pages 26 to 34
Pages 26 to 34 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000BT
Page 26
General Features
Good Read Beep Length Specifies the duration of a good read beep. START/END LENGTH
BAR CODE
60msec
80msec
100msec
120msec
140msec
160msec
2-10
PowerScan® 7000BT SRI
Page 27
LED and Beeper Indicators
Good Read Beep Length, continued START/END LENGTH
BAR CODE
180msec
200msec
Product Reference Guide
2-11
Page 28
General Features
Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. START/END VOLUME
BAR CODE
Low
Medium
High
2-12
PowerScan® 7000BT SRI
Page 29
Scanning Features
Scanning Features Scan Mode Selects the scan operating mode for the scanner. Selections are: •
Single, When the trigger is pulled, scanning is activated until five seconds have elapsed or a bar code has been read or the trigger is released
•
Triggerless, When the trigger is pulled, scanning is activated until any of the following occur: - Active Scanning Time has expired - a bar code has been read - the trigger is pulled a second time The Double Read Timeout feature gates double reads while in this mode.
•
Stand, No trigger pull is required to read a bar code while in this mode. Scanning is turned on automatically (auto-sense) when an item is placed in the scanner's field of view and is turned off again when a bar code is read or Active Scanning Time has expired. The Double Read Timeout feature gates double reads while in this mode. If the trigger is pulled, the scanner acts as if it is in single read mode. Upon exiting Single Read mode while Stand Mode is enabled, the software will delay 2 seconds before beginning its auto-sense operation. NOTE
•
Stand With Illumination, Same as the option above, except that illumination is on while in this mode.
Product Reference Guide
2-13
Page 30
General Features
Scan Mode, continued START/END MODE
BAR CODE
Single
Triggerless
Stand
Stand w/Illum
2-14
PowerScan® 7000BT SRI
Page 31
Scanning Features
Active Scanning Time This setting determines the amount of time the scanner continues to scan in triggerless or stand mode (see Scan Mode) once scanning has been activated. START/END DURATION
BAR CODE
1 Second
2 Seconds
5 Seconds
15 Seconds
30 Seconds
1 Minute
Product Reference Guide
2-15
Page 32
General Features
Active Scanning Time, continued START/END DURATION
BAR CODE
2 Minutes
3 Minutes
4 Minutes
Laser Pointer Control The Laser Pointer is a value-added option which might not have been included when your scanner was ordered. NOTE
When the trigger is pressed and Scan Mode is set to Single, the laser pointer will be activated for the time period configured by this feature. Immediately following this, the scanner will start scanning. Disabling this feature turns the pointer off.
2-16
PowerScan® 7000BT SRI
Page 33
Scanning Features
Laser Pointer Control, continued START/END DURATION
BAR CODE
Disable
0.1 Seconds
0.2 Seconds
0.3 Seconds
0.4 Seconds
0.5 Seconds
Product Reference Guide
2-17
Page 34
General Features
Laser Pointer Control, continued START/END DURATION
BAR CODE
0.6 Seconds
0.8 Seconds
1 Second
1.2 Seconds
1.5 Seconds
2 Seconds
2.5 Seconds
2-18
PowerScan® 7000BT SRI