Page 217
PDF 417
PDF 417, continued PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For PDF 417 bar codes, only the data characters are included in the length calculations. NOTE
Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 600 decimal
Product Reference Guide
6-101
Page 218
Symbologies
PDF 417, continued Minimum Reads This feature specifies the minimum number of consecutive times a PDF 417 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-102
PowerScan® 7000BT SRI
Page 219
Micro PDF 417
Micro PDF 417 The following options apply to the Micro PDF 417 symbology.
Disable/Enable Micro PDF 417 When this feature is disabled, the scanner will not read Micro PDF 417 bar codes.
START/END STATE
BAR CODE
Disable Micro PDF417
Enable Micro PDF 417
Product Reference Guide
6-103
Page 220
Symbologies
Micro PDF 417, continued PDF 128 Emulation Depending upon the other configuration features listed below, this feature specifies which AIM ID to use for Micro PDF 417 labels when performing EAN 128 or Code 128 emulation. •
If this feature (PDF 128 Emulation) is enabled, and the feature AIM ID is enabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the appropriate EAN 128 or Code 128 AIM ID is appended to the label data.
•
If this feature (PDF 128 Emulation) is disabled, and the feature AIM ID is enabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the Micro PDF 417 AIM ID is appended to the label data.
•
If this feature (PDF 128 Emulation) is enabled, and the feature AIM ID is disabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the label type is changed to either EAN 128 or Code 128 as applicable.
•
If this feature (PDF 128 Emulation) is disabled, and the feature AIM ID is disabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the label type remains Micro PDF 417.
START/END STATE
BAR CODE
Disable PDF 128 Emulation
Enable PDF 128 Emulation
6-104
PowerScan® 7000BT SRI
Page 221
Micro PDF 417
Micro PDF 417, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions.
Product Reference Guide
6-105
Page 222
Symbologies
Micro PDF 417, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
6-106
PowerScan® 7000BT SRI
Page 223
Micro PDF 417
Micro PDF 417, continued Micro PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Micro PDF 417 bar codes, only the data characters are included in the length calculations. NOTE
Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 366 decimal
Product Reference Guide
6-107
Page 224
Symbologies
Micro PDF 417, continued Minimum Reads This feature specifies the minimum number of consecutive times a Micro PDF 417 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-108
PowerScan® 7000BT SRI