Page 217

PDF 417

PDF 417, continued PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For PDF 417 bar codes, only the data characters are included in the length calculations. NOTE

Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 600 decimal

Product Reference Guide

6-101

Page 218

Symbologies

PDF 417, continued Minimum Reads This feature specifies the minimum number of consecutive times a PDF 417 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-102

PowerScan® 7000BT SRI

Page 219

Micro PDF 417

Micro PDF 417 The following options apply to the Micro PDF 417 symbology.

Disable/Enable Micro PDF 417 When this feature is disabled, the scanner will not read Micro PDF 417 bar codes.

START/END STATE

BAR CODE

Disable Micro PDF417

Enable Micro PDF 417

Product Reference Guide

6-103

Page 220

Symbologies

Micro PDF 417, continued PDF 128 Emulation Depending upon the other configuration features listed below, this feature specifies which AIM ID to use for Micro PDF 417 labels when performing EAN 128 or Code 128 emulation. •

If this feature (PDF 128 Emulation) is enabled, and the feature AIM ID is enabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the appropriate EAN 128 or Code 128 AIM ID is appended to the label data.

•

If this feature (PDF 128 Emulation) is disabled, and the feature AIM ID is enabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the Micro PDF 417 AIM ID is appended to the label data.

•

If this feature (PDF 128 Emulation) is enabled, and the feature AIM ID is disabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the label type is changed to either EAN 128 or Code 128 as applicable.

•

If this feature (PDF 128 Emulation) is disabled, and the feature AIM ID is disabled while the scanner is performing EAN 128 or Code 128 emulation for a Micro PDF 417 label, the label type remains Micro PDF 417.

START/END STATE

BAR CODE

Disable PDF 128 Emulation

Enable PDF 128 Emulation

6-104

PowerScan® 7000BT SRI

Page 221

Micro PDF 417

Micro PDF 417, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Micro PDF 417 Length 1, Length 2 Programming Instructions.

Product Reference Guide

6-105

Page 222

Symbologies

Micro PDF 417, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

6-106

PowerScan® 7000BT SRI

Page 223

Micro PDF 417

Micro PDF 417, continued Micro PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Micro PDF 417 bar codes, only the data characters are included in the length calculations. NOTE

Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 366 decimal

Product Reference Guide

6-107

Page 224

Symbologies

Micro PDF 417, continued Minimum Reads This feature specifies the minimum number of consecutive times a Micro PDF 417 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-108

PowerScan® 7000BT SRI