For the Datalogic 7000BT

Page 225

Appendix A Product Specifications Optical and Read Performance Parameters Parameter Scanning Width Minimum Resolution

Depth of Field (75% read rate; 90% PCS; Code 39 with 2.5:1 W/N ratio except for 13 mils)

Specification 2” wide at 1” from scanner 6” wide at 7” from scanner 4mil minimum element size (at some distance, no implied DOF) 5 mil, 3 to 6”/7.6 to 15.2 cm 7.5 mil, 2 to 16”/5.1 to 40.6 cm 10 mil, 1.5 to 22”/3.8 to 55.9 cm 13 mil, 1 to 30”/2.5 to 76.2 cm 20 mil, 1 to 42”/2.5 to 106.7 cm 55 mil, 2 to 80”/5.1 to 203.2 cm Minimum distance determined by symbol length and scan angle. Printing resolution, contrast and ambient light dependent. 13 mil DOF based on UPC. All others are Code 39. All labels grade A, minimum illumination: 300 Lux, 20° C, label perpendicular to the optical axis.

Minimum Print Contrast Ratio

20%

Skewa (Yaw)

± 60°

Pitcha.

± 65°

Rolla.

± 40° a. DOF will be reduced whenever the label is not perpendicular to the optical axis.

Product Reference Guide

A-1

Page 226

Physical Properties: Scanner Parameter

Specification

Dimensions (Typical): Height

7.5”/190 mm

Length

4.5”/115 mm

Width

3.0”/75 mm

Weight

13.4 ounces/380 g (battery included)

Physical Properties: Base Station Parameter

Specification

Dimensions (Typical): Height

1.8” (46 mm), 5.45” (13.84cm) w/antenna

Length

9.5” (24.13cm)

Width

4.0” (10.16cm), 4.75” (12.07cm) w/antenna

Weight

11.5 ounces/326 g

Electrical Parameters: Base Station Parameter Input Voltage Input Power Maximum Operating Power Typical Operating Power Typical Standby Power Input Current Maximum Operating Current Typical Operating Current Typical Standby Current Sleep Mode Current

A-2

Specification +4 to 14 VDC 7.5 W (while charging) 1.4 W 1W 1500 mA @ 5VDC 280 mA @ 5VDC 210 mA @ 5VDC Less than 1 mA

PowerScan® 7000BT SRI

Page 227

Environmental Parameters: Scanner

Environmental Parameters: Scanner Parameter Mechanical Shock

Contaminants Spray/rain Dust/particulate

Specification 50 drops from 6.5 feet (2 meters) to concrete -4° F to 122° F (-20° C to +50° C) Scanners: Spray/rain, IEC 529-IPX5 Dust/particulate, IEC 529-IP6X Base Stations and Charger: Spray/rain, IEC 529-IPX4 Dust/particulate, IEC 529-IP5X

Temperature Ranges: Operating

-4° F to +122° F (-20° C to +50° C)

Storage

-40° F to +140° F (-40° C to + 60°C)

Humidity Beeper/Speaker Vibration

Product Reference Guide

0 to 95% non-condensing 87 dBA for operator at a distance of 19” (50cm) Meets MIL-STD-810F

A-3

Page 228

NOTES

A-4

PowerScan® 7000BT SRI