Page 207

Standard 2 of 5

Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology.

Disable/Enable Standard 2 of 5 When this feature is disabled, the scanner will not read Standard 2 of 5 bar codes.

Check Digit Verification When enabled, the scanner will verify the check digit of the labels.

Check Digit Transmit When this option is enabled, the scanner will transmit the check digit.

Product Reference Guide

6-91

Page 208

Symbologies

Standard 2 of 5, continued START/END STATE

BAR CODE

Disable Std 2 of 5

Enable Std 2 of 5

Disable Check Digit Verification

Enable Check Digit Verification

Disable Check Digit Transmission

Enable Check Digit Transmission

6-92

PowerScan® 7000BT SRI

Page 209

Standard 2 of 5

Standard 2 of 5, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions.

Product Reference Guide

6-93

Page 210

Symbologies

Standard 2 of 5, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

6-94

PowerScan® 7000BT SRI

Page 211

Standard 2 of 5

Standard 2 of 5, continued Standard 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Standard 2 of 5 bar codes, all check and data characters are included in the length calculations. NOTE

4. Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 008

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal

Product Reference Guide

6-95

Page 212

Symbologies

Standard 2 of 5, continued Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 bar codes. When parts of a Standard 2 of 5 label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE

BAR CODE

Disable Std 2 of 5 Stitching

Enable Std 2 of 5 Stitching

6-96

PowerScan® 7000BT SRI

Page 213

Standard 2 of 5

Standard 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-97

Page 214

Symbologies

PDF 417 The following options apply to the PDF 417 symbology.

Disable/Enable PDF 417 When this feature is disabled, the scanner will not read PDF 417 bar codes.

START/END STATE

BAR CODE

Disable PDF417

Enable PDF 417

6-98

PowerScan® 7000BT SRI

Page 215

PDF 417

PDF 417, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the PDF 417 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the PDF 417 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the PDF 417 Length 1, Length 2 Programming Instructions.

Product Reference Guide

6-99

Page 216

Symbologies

PDF 417, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

6-100

PowerScan® 7000BT SRI