The text of a manual · part 22 of 31
PowerScan 7000BT SRI Linear Imager Product Reference Guide: Symbologies, pages 197 to 206
Pages 197 to 206 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000BT
Page 197
Code 11
Code 11, continued Code 11 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 11 bar codes, only the data characters are included in the length calculations. NOTE
4. Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 004
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal
Product Reference Guide
6-81
Page 198
Symbologies
Code 11, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 11 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-82
PowerScan® 7000BT SRI
Page 199
MSI/Plessey
MSI/Plessey The following options apply to the MSI/Plessey symbology.
Disable/Enable MSI/Plessey When this feature is disabled, the scanner will not read MSI/Plessey bar codes.
Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified.
Check Digit Transmit When this option is enabled, the scanner will transmit one-digit or twodigit check digits, depending upon the setting for check digit verification.
Product Reference Guide
6-83
Page 200
Symbologies
MSI/Plessey, continued START/END STATE
BAR CODE
Disable MSI/Plessey
Enable MSI/Plessey
Disable Check Digit Verification
Enable Check Digit Verification
1-Digit Check Digit Verification
6-84
PowerScan® 7000BT SRI
Page 201
MSI/Plessey
MSI/Plessey, continued START/END STATE
BAR CODE
2-Digit Check Digit Verification
Disable Check Digit Transmission
Enable Check Digit Transmission
Product Reference Guide
6-85
Page 202
Symbologies
MSI/Plessey, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the MSI/Plessey Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the MSI/Plessey Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the MSI/Plessey Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the MSI/Plessey Length 1, Length 2 Programming Instructions.
6-86
PowerScan® 7000BT SRI
Page 203
MSI/Plessey
MSI/Plessey, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide
6-87
Page 204
Symbologies
MSI/Plessey, continued MSI/Plessey Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For MSI/Plessey bar codes, all check and data characters are included in the length calculations. NOTE
Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 004
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 016 decimal
6-88
PowerScan® 7000BT SRI
Page 205
MSI/Plessey
MSI/Plessey, continued MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey bar codes. When parts of an MSI/Plessey label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE
BAR CODE
Disable MSI/Plessey Stitching
Enable MSI/Plessey Stitching
Product Reference Guide
6-89
Page 206
Symbologies
MSI/Plessey, continued Minimum Reads This feature specifies the minimum number of consecutive times an MSI/Plessey label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-90
PowerScan® 7000BT SRI