Page 197

Code 11

Code 11, continued Code 11 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 11 bar codes, only the data characters are included in the length calculations. NOTE

4. Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 004

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal

Product Reference Guide

6-81

Page 198

Symbologies

Code 11, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 11 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-82

PowerScan® 7000BT SRI

Page 199

MSI/Plessey

MSI/Plessey The following options apply to the MSI/Plessey symbology.

Disable/Enable MSI/Plessey When this feature is disabled, the scanner will not read MSI/Plessey bar codes.

Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified.

Check Digit Transmit When this option is enabled, the scanner will transmit one-digit or twodigit check digits, depending upon the setting for check digit verification.

Product Reference Guide

6-83

Page 200

Symbologies

MSI/Plessey, continued START/END STATE

BAR CODE

Disable MSI/Plessey

Enable MSI/Plessey

Disable Check Digit Verification

Enable Check Digit Verification

1-Digit Check Digit Verification

6-84

PowerScan® 7000BT SRI

Page 201

MSI/Plessey

MSI/Plessey, continued START/END STATE

BAR CODE

2-Digit Check Digit Verification

Disable Check Digit Transmission

Enable Check Digit Transmission

Product Reference Guide

6-85

Page 202

Symbologies

MSI/Plessey, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the MSI/Plessey Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the MSI/Plessey Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the MSI/Plessey Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the MSI/Plessey Length 1, Length 2 Programming Instructions.

6-86

PowerScan® 7000BT SRI

Page 203

MSI/Plessey

MSI/Plessey, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

Product Reference Guide

6-87

Page 204

Symbologies

MSI/Plessey, continued MSI/Plessey Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For MSI/Plessey bar codes, all check and data characters are included in the length calculations. NOTE

Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 004

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 016 decimal

6-88

PowerScan® 7000BT SRI

Page 205

MSI/Plessey

MSI/Plessey, continued MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey bar codes. When parts of an MSI/Plessey label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE

BAR CODE

Disable MSI/Plessey Stitching

Enable MSI/Plessey Stitching

Product Reference Guide

6-89

Page 206

Symbologies

MSI/Plessey, continued Minimum Reads This feature specifies the minimum number of consecutive times an MSI/Plessey label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-90