Code 93
Code 93 The following options apply to the Code 93 symbology.
Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 bar codes.
START/END STATE
BAR CODE
Disable Code 93
Enable Code 93
Product Reference Guide
6-71
Page 188
Symbologies
Code 93, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 93 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 93 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 93 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 93 Length 1, Length 2 Programming Instructions.
6-72
PowerScan® 7000BT SRI
Page 189
Code 93
Code 93, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide
6-73
Page 190
Symbologies
Code 93, continued Code 93 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 93 bar codes, only the data characters are included in the length calculations. NOTE
4. Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal
6-74
PowerScan® 7000BT SRI
Page 191
Code 93
Code 93, continued Code 93 Stitching Enables/disables stitching for Code 93 bar codes. When parts of a Code 93 label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE
BAR CODE
Disable Code 93 Stitching
Enable Code 93 Stitching
Product Reference Guide
6-75
Page 192
Symbologies
Code 93, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 93 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-76
PowerScan® 7000BT SRI
Page 193
Code 11
Code 11 The following options apply to the Code 11 symbology.
Disable/Enable Code 11 When this feature is disabled, the scanner will not read Code 11 bar codes.
START/END STATE
BAR CODE
Disable Code 11
Enable Code 11
Product Reference Guide
6-77
Page 194
Symbologies
Code 11, continued Number of Check Characters Specifies the number of Code 11 check characters (one or two) to be calculated and verified.
Check Character Transmit Enables/disables transmission of Code 11 check characters.
START/END STATE
BAR CODE
One Check Character
Two Check Characters
Disable Check Char Transmission
Enable Check Char Transmission
6-78
PowerScan® 7000BT SRI
Page 195
Code 11
Code 11, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 11 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 11 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 11 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 11 Length 1, Length 2 Programming Instructions.
Product Reference Guide
6-79
Page 196
Symbologies
Code 11, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
6-80