Page 177
Codabar
Codabar, continued START/END STATE
BAR CODE
Disable Codabar
Enable Codabar
Disable Check Char Verification
Enable Check Char Verification
Disable Check Char Transmission
Enable Check Char Transmission
Product Reference Guide
6-61
Page 178
Symbologies
Codabar, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Codabar Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Codabar Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Codabar Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Codabar Length 1, Length 2 Programming Instructions.
6-62
PowerScan® 7000BT SRI
Page 179
Codabar
Codabar, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide
6-63
Page 180
Symbologies
Codabar, continued Codabar Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Codabar bar codes, all start, stop, check and data characters are included in the length calculations. NOTE
4. Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal
6-64
PowerScan® 7000BT SRI
Page 181
Codabar
Codabar, continued Quiet Zones This feature enable/disables the requirement that quiet zones must be present for Codabar bar codes.
START/END STATE
BAR CODE
Don’t require Quiet Zones
Require Quiet Zones
Product Reference Guide
6-65
Page 182
Symbologies
Codabar, continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application.
Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below.
Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match.
6-66
PowerScan® 7000BT SRI
Page 183
Codabar
Codabar, continued START/END STATE
BAR CODE
Start/Stop Type: ABCD/ TN*E
Start/Stop Type: ABCD/ ABCD
Start/Stop Type: abcd/tn*e
Start/Stop Type: abcd/ abcd
Disable Start/Stop Char Transmission
Enable Start/Stop Char Transmission
Product Reference Guide
6-67
Page 184
Symbologies
Codabar, continued START/END STATE
BAR CODE
Disable Start/Stop Char Match
Enable Start/Stop Char Match
6-68
PowerScan® 7000BT SRI
Page 185
Codabar
Codabar, continued Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE
BAR CODE
Disable Codabar Stitching
Enable Codabar Stitching
Product Reference Guide
6-69
Page 186
Symbologies
Codabar, continued Minimum Reads This feature specifies the minimum number of consecutive times an Codabar label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-70
PowerScan® 7000BT SRI