Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 31

PowerScan 7000BT SRI Linear Imager Product Reference Guide: Symbologies, pages 167 to 176

Pages 167 to 176 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide

The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 7000BT

Page 167

Code 128 and EAN 128

Code 128 and EAN 128, continued Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE

BAR CODE

Disable Code 128 Stitching

Enable Code 128 Stitching

Product Reference Guide

6-51

Page 168

Symbologies

Code 128 and EAN 128, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 128 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-52

PowerScan® 7000BT SRI

Page 169

Interleaved 2 of 5

Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.

Disable/Enable Interleaved 2 of 5 When this feature is disabled, the scanner will not read Interleaved 2 of 5 bar codes.

Check Digit Calculation When enabled, the scanner will calculate the check digit of the labels.

Check Digit Transmit Enable this option to transmit the check digit with scanned bar code data.

Product Reference Guide

6-53

Page 170

Symbologies

Interleaved 2 of 5, continued START/END STATE

BAR CODE

Disable Interleaved 2 of 5

Enable Interleaved 2 of 5

Disable Check Digit Calculation

Enable Check Digit Calculation

Disable Check Digit Transmission

Enable Check Digit Transmission

6-54

PowerScan® 7000BT SRI

Page 171

Interleaved 2 of 5

Interleaved 2 of 5, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions.

Product Reference Guide

6-55

Page 172

Symbologies

Interleaved 2 of 5, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

6-56

PowerScan® 7000BT SRI

Page 173

Interleaved 2 of 5

Interleaved 2 of 5, continued Interleaved 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation.

NOTE

For Interleaved 2 of 5 bar codes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.

4. Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 006

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal

Product Reference Guide

6-57

Page 174

Symbologies

Interleaved 2 of 5, continued Interleaved 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an Interleaved 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE

BAR CODE

Disable Interleaved 2 of 5 Stitching

Enable Interleaved 2 of 5 Stitching

6-58

PowerScan® 7000BT SRI

Page 175

Interleaved 2 of 5

Interleaved 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-59

Page 176

Symbologies

Codabar The following options apply to the Codabar symbology.

Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar bar codes.

Check Character Verification When enabled, the scanner will verify the check character of the labels.

Check Character Transmit Enable this option to transmit the check character with scanned bar code data.

6-60

PowerScan® 7000BT SRI