For the Datalogic 7000BT
Page 157
Code 39
Code 39, continued Quiet Zones This feature enables/disables the requirement that quiet zones must be present for Code 39 bar codes.
START/END STATE
BAR CODE
Don’t require Quiet Zones
Require Quiet Zones
Product Reference Guide
6-41
Page 158
Symbologies
Code 39, continued Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE
BAR CODE
Disable Code 39 Stitching
Enable Code 39 Stitching
6-42
PowerScan® 7000BT SRI
Page 159
Code 39
Code 39, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 39 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
6-43
Page 160
Symbologies
Pharmacode 39 The following options apply to the Pharmacode 39 symbology.
Disable/Enable Pharmacode 39 When this feature is disabled, the scanner will not read Pharmacode 39 bar codes.
START/END STATE
BAR CODE
Disable Pharmacode 39
Enable Pharmacode 39
6-44
PowerScan® 7000BT SRI
Page 161
Pharmacode 39
Pharmacode 39, continued Start/Stop Characters Enables or disables transmission of Pharmacode 39 start/stop characters.
Check Character Transmit Enable this option to transmit the check character with scanned bar code data. START/END STATE
BAR CODE
Don’t Transmit Start/Stop Characters
Transmit Start/Stop Characters
Disable Check Char Transmission
Enable Check Char Transmission
Product Reference Guide
6-45
Page 162
Symbologies
Code 128 and EAN 128 Enable/Disable Code 128, When this feature is disabled, the scanner will not read Cod 128 bar codes. Enable/Disable EAN 128, Enables/disables the ability of the scanner to decode EAN-128 labels. When disabled, EAN128 labels are transmitted in Code128 data format. When enabled, EAN128 labels are transmitted in EAN128 data format START STATE
BAR CODE
Disable Code 128
Enable Code 128
Disable EAN 128
Enable EAN 128
END
6-46
PowerScan® 7000BT SRI
Page 163
Code 128 and EAN 128
Code 128 and EAN 128, continued Transmit Function Characters Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. Function codes are transmitted as follows: •
FNC1 = 80 hex
•
FNC2 = 81 hex
•
FNC3 = 82 hex
•
FNC4 = 83 hex
START/END STATE
BAR CODE
Don’t Transmit Function Characters
Transmit Function Characters
Product Reference Guide
6-47
Page 164
Symbologies
Code 128 and EAN 128, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 128 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 128 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 128 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 128 Length 1, Length 2 Programming Instructions.
6-48
PowerScan® 7000BT SRI
Page 165
Code 128 and EAN 128
Code 128 and EAN 128, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide
6-49
Page 166
Symbologies
Code 128 and EAN 128, continued Code 128 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 128 bar codes, only the data characters are included in the length calculations. NOTE
4. Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 080 decimal
6-50