Page 157

Code 39

Code 39, continued Quiet Zones This feature enables/disables the requirement that quiet zones must be present for Code 39 bar codes.

START/END STATE

BAR CODE

Don’t require Quiet Zones

Require Quiet Zones

Product Reference Guide

6-41

Page 158

Symbologies

Code 39, continued Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START/END STATE

BAR CODE

Disable Code 39 Stitching

Enable Code 39 Stitching

6-42

PowerScan® 7000BT SRI

Page 159

Code 39

Code 39, continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 39 label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-43

Page 160

Symbologies

Pharmacode 39 The following options apply to the Pharmacode 39 symbology.

Disable/Enable Pharmacode 39 When this feature is disabled, the scanner will not read Pharmacode 39 bar codes.

START/END STATE

BAR CODE

Disable Pharmacode 39

Enable Pharmacode 39

6-44

PowerScan® 7000BT SRI

Page 161

Pharmacode 39

Pharmacode 39, continued Start/Stop Characters Enables or disables transmission of Pharmacode 39 start/stop characters.

Check Character Transmit Enable this option to transmit the check character with scanned bar code data. START/END STATE

BAR CODE

Don’t Transmit Start/Stop Characters

Transmit Start/Stop Characters

Disable Check Char Transmission

Enable Check Char Transmission

Product Reference Guide

6-45

Page 162

Symbologies

Code 128 and EAN 128 Enable/Disable Code 128, When this feature is disabled, the scanner will not read Cod 128 bar codes. Enable/Disable EAN 128, Enables/disables the ability of the scanner to decode EAN-128 labels. When disabled, EAN128 labels are transmitted in Code128 data format. When enabled, EAN128 labels are transmitted in EAN128 data format START STATE

BAR CODE

Disable Code 128

Enable Code 128

Disable EAN 128

Enable EAN 128

END

6-46

PowerScan® 7000BT SRI

Page 163

Code 128 and EAN 128

Code 128 and EAN 128, continued Transmit Function Characters Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. Function codes are transmitted as follows: •

FNC1 = 80 hex

•

FNC2 = 81 hex

•

FNC3 = 82 hex

•

FNC4 = 83 hex

START/END STATE

BAR CODE

Don’t Transmit Function Characters

Transmit Function Characters

Product Reference Guide

6-47

Page 164

Symbologies

Code 128 and EAN 128, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 128 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 128 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 128 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 128 Length 1, Length 2 Programming Instructions.

6-48

PowerScan® 7000BT SRI

Page 165

Code 128 and EAN 128

Code 128 and EAN 128, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

Product Reference Guide

6-49

Page 166

Symbologies

Code 128 and EAN 128, continued Code 128 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 128 bar codes, only the data characters are included in the length calculations. NOTE

4. Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 080 decimal

6-50