Page 147
RSS Expanded
RSS Expanded, continued RSS Expanded 2D Component This feature controls the requirement that a 2D label component be decoded when an RSS Expanded base label is decoded. •
Enable, Requires that a 2D label component be decoded when an RSS Expanded base label is decoded.
•
Disable, Does NOT require a 2D label component to be decoded when an RSS Expanded base label is decoded.
START/END STATE
BAR CODE
Disable RSS Expanded 2D Component
Enable RSS Expanded 2D Component
Product Reference Guide
6-31
Page 148
Symbologies
RSS Limited The following options apply to the RSS Limited symbology.
Disable/Enable RSS Limited When this feature is disabled, the scanner will not read RSS Limited bar codes.
UCC/EAN 128 Emulation When enabled, RSS Limited bar codes will be translated to the UCC/ EAN 128 label data format.
START/END STATE
BAR CODE
Disable RSS Limited
Enable RSS Limited
Disable UCC/EAN 128 Emulation
Enable UCC/EAN 128 Emulation
6-32
PowerScan® 7000BT SRI
Page 149
RSS Limited
RSS Limited, continued Minimum Reads This feature specifies the minimum number of consecutive times an RSS Limited label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
6-33
Page 150
Symbologies
RSS Limited, continued RSS Limited 2D Component This feature controls the requirement that a 2D label component be decoded when an RSS Limited base label is decoded. •
Enable, Requires that a 2D label component be decoded when an RSS Limited base label is decoded.
•
Disable, Does NOT require a 2D label component to be decoded when an RSS Limited base label is decoded.
START/END STATE
BAR CODE
Disable RSS Limited 2D Component
Enable RSS Limited 2D Component
6-34
PowerScan® 7000BT SRI
Page 151
Code 39
Code 39 The following options apply to the Code 39 symbology.
Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 bar codes.
Check Character Calculation When enabled, the scanner will calculate the check character of the labels and verify it against the check character in the label. If the check characters do not match, the label is not decoded. Turn this option on only when a checksum is present in the Code 39 labels.
Check Character Transmit Enable this option to transmit the check character with scanned bar code data.
Start/Stop Characters Enables/disables transmission of Code39 start and stop characters.
Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 fullASCII characters
Product Reference Guide
6-35
Page 152
Symbologies
Code 39, continued START/END STATE
BAR CODE
Disable Code 39
Enable Code 39
Disable Check Char Calculation
Enable Check Char Calculation
Disable Check Char Transmission
Enable Check Char Transmission
6-36
PowerScan® 7000BT SRI
Page 153
Code 39
Code 39, continued START/END STATE
BAR CODE
Don’t Transmit Start/Stop Characters
Transmit Start/Stop Characters
Disable Code 39 Full ASCII
Enable Code 39 Full ASCII
Product Reference Guide
6-37
Page 154
Symbologies
Code 39, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 39 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 39 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 39 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 39 Length 1, Length 2 Programming Instructions.
6-38
PowerScan® 7000BT SRI
Page 155
Code 39
Code 39, continued
START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide
6-39
Page 156
Symbologies
Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 39 bar codes, all check, data and full ASCII shift characters are included in the length calculations. Start/Stop characters are not included. NOTE
4. Scan the START/END bar code.
START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal
6-40
PowerScan® 7000BT SRI