Page 147

RSS Expanded

RSS Expanded, continued RSS Expanded 2D Component This feature controls the requirement that a 2D label component be decoded when an RSS Expanded base label is decoded. •

Enable, Requires that a 2D label component be decoded when an RSS Expanded base label is decoded.

•

Disable, Does NOT require a 2D label component to be decoded when an RSS Expanded base label is decoded.

START/END STATE

BAR CODE

Disable RSS Expanded 2D Component

Enable RSS Expanded 2D Component

Product Reference Guide

6-31

Page 148

Symbologies

RSS Limited The following options apply to the RSS Limited symbology.

Disable/Enable RSS Limited When this feature is disabled, the scanner will not read RSS Limited bar codes.

UCC/EAN 128 Emulation When enabled, RSS Limited bar codes will be translated to the UCC/ EAN 128 label data format.

START/END STATE

BAR CODE

Disable RSS Limited

Enable RSS Limited

Disable UCC/EAN 128 Emulation

Enable UCC/EAN 128 Emulation

6-32

PowerScan® 7000BT SRI

Page 149

RSS Limited

RSS Limited, continued Minimum Reads This feature specifies the minimum number of consecutive times an RSS Limited label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-33

Page 150

Symbologies

RSS Limited, continued RSS Limited 2D Component This feature controls the requirement that a 2D label component be decoded when an RSS Limited base label is decoded. •

Enable, Requires that a 2D label component be decoded when an RSS Limited base label is decoded.

•

Disable, Does NOT require a 2D label component to be decoded when an RSS Limited base label is decoded.

START/END STATE

BAR CODE

Disable RSS Limited 2D Component

Enable RSS Limited 2D Component

6-34

PowerScan® 7000BT SRI

Page 151

Code 39

Code 39 The following options apply to the Code 39 symbology.

Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 bar codes.

Check Character Calculation When enabled, the scanner will calculate the check character of the labels and verify it against the check character in the label. If the check characters do not match, the label is not decoded. Turn this option on only when a checksum is present in the Code 39 labels.

Check Character Transmit Enable this option to transmit the check character with scanned bar code data.

Start/Stop Characters Enables/disables transmission of Code39 start and stop characters.

Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 fullASCII characters

Product Reference Guide

6-35

Page 152

Symbologies

Code 39, continued START/END STATE

BAR CODE

Disable Code 39

Enable Code 39

Disable Check Char Calculation

Enable Check Char Calculation

Disable Check Char Transmission

Enable Check Char Transmission

6-36

PowerScan® 7000BT SRI

Page 153

Code 39

Code 39, continued START/END STATE

BAR CODE

Don’t Transmit Start/Stop Characters

Transmit Start/Stop Characters

Disable Code 39 Full ASCII

Enable Code 39 Full ASCII

Product Reference Guide

6-37

Page 154

Symbologies

Code 39, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the Code 39 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 39 Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the Code 39 Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the Code 39 Length 1, Length 2 Programming Instructions.

6-38

PowerScan® 7000BT SRI

Page 155

Code 39

Code 39, continued

START/END MODE

BAR CODE

Variable Length Decoding

Fixed Length Decoding

Product Reference Guide

6-39

Page 156

Symbologies

Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 39 bar codes, all check, data and full ASCII shift characters are included in the length calculations. Start/Stop characters are not included. NOTE

4. Scan the START/END bar code.

START/END SETTING

BAR CODE

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 003

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050 decimal

6-40