The text of a manual · part 16 of 31
PowerScan 7000BT SRI Linear Imager Product Reference Guide: Symbologies, pages 137 to 146
Pages 137 to 146 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000BT
Page 137
Add-ons
Add-ons, continued START/END STATE
BAR CODE
Disable Optional 2Digit Add-ons
Enable Optional 2-Digit Add-ons
Disable Optional 5Digit Add-ons
Enable Optional 5-Digit Add-ons
Disable Optional Code 128 Add-ons
Enable Optional Code 128 Add-ons
Product Reference Guide
6-21
Page 138
Symbologies
RSS-14 The following options apply to the RSS-14 symbology.
Disable/Enable RSS-14 When this feature is disabled, the scanner will not read RSS-14 bar codes.
UCC/EAN 128 Emulation When enabled, RSS-14 bar codes will be translated to the UCC/EAN 128 label data format.
6-22
PowerScan® 7000BT SRI
Page 139
RSS-14
RSS-14, continued START/END STATE
BAR CODE
Disable RSS-14
Enable RSS-14
Disable UCC/EAN 128 Emulation
Enable UCC/EAN 128 Emulation
Product Reference Guide
6-23
Page 140
Symbologies
RSS-14, continued Minimum Reads This feature specifies the minimum number of consecutive times an RSS-14 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-24
PowerScan® 7000BT SRI
Page 141
RSS-14
RSS-14, continued RSS-14 2D Component This feature controls the requirement that a 2D label component be decoded when an RSS-14 base label is decoded. •
Enable, Requires that a 2D label component be decoded when an RSS-14 base label is decoded.
•
Disable, Does NOT require a 2D label component to be decoded when an RSS-14 base label is decoded.
START/END STATE
BAR CODE
Disable RSS-14 2D Component
Enable RSS-14 2D Component
Product Reference Guide
6-25
Page 142
Symbologies
RSS Expanded The following options apply to the RSS Expanded symbology.
Disable/Enable RSS Expanded When this feature is disabled, the scanner will not read RSS Expanded bar codes.
UCC/EAN 128 Emulation When enabled, RSS Expanded bar codes will be translated to the UCC/ EAN 128 label data format.
START/END STATE
BAR CODE
Disable RSS Expanded
Enable RSS Expanded
Disable UCC/EAN 128 Emulation
Enable UCC/EAN 128 Emulation
6-26
PowerScan® 7000BT SRI
Page 143
RSS Expanded
RSS Expanded, continued Length Control Fixed Length Decoding, When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding, When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the first fixed length by following the RSS Expanded Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the RSS Expanded Length 1, Length 2 Programming Instructions. Configuring Variable Length Decoding: 1. Scan the START/END bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the START/END bar code. 4. Set Length 1 to the minimum length by following the RSS Expanded Length 1, Length 2 Programming Instructions. 5. Set Length 2 to the maximum length by following the RSS Expanded Length 1, Length 2 Programming Instructions.
Product Reference Guide
6-27
Page 144
Symbologies
RSS Expanded, continued START/END MODE
BAR CODE
Variable Length Decoding
Fixed Length Decoding
6-28
PowerScan® 7000BT SRI
Page 145
RSS Expanded
RSS Expanded, continued RSS Expanded Length 1, Length 2 Programming Instructions 1. Scan the START/END bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For RSS Expanded bar codes, only the data characters are included in the length calculations. NOTE
4. Scan the START/END bar code. START/END SETTING
BAR CODE
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 074 decimal
Product Reference Guide
6-29
Page 146
Symbologies
RSS Expanded, continued Minimum Reads This feature specifies the minimum number of consecutive times an RSS Expanded label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-30