Page 127
UPC-E
UPC-E, continued Minimum Reads This feature specifies the minimum number of consecutive times a UPCE label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
6-11
Page 128
Symbologies
GTIN The following options apply to the GTIN label data format.
Disable/Enable GTIN When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format. START/END STATE
BAR CODE
Disable GTIN
Enable GTIN
6-12
PowerScan® 7000BT SRI
Page 129
EAN-13
EAN-13 The following options apply to the EAN-13 symbology.
Disable/Enable EAN-13 When disabled, the scanner will not read EAN-13 bar codes.
Check Digit Transmission Enable this option to transmit the check digit along with EAN-13 bar code data.
EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character.
ISBN When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number). These codes are used for books and magazines. Labels with ISBN codes start with "978". Example:
Bar code data:
“9789572222720”
Output:
“9572222724”
Product Reference Guide
6-13
Page 130
Symbologies
EAN-13, continued START/END STATE
BAR CODE
Disable EAN-13
Enable EAN-13
Don’t Send Check Digit
Send Check Digit
Don’t Transmit EAN-13 Flag 1 Char
6-14
PowerScan® 7000BT SRI
Page 131
EAN-13
EAN-13, continued START/END STATE
BAR CODE
Transmit EAN-13 Flag 1 Char
Disable ISBN
Enable ISBN
Product Reference Guide
6-15
Page 132
Symbologies
EAN-13, continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
6-16
PowerScan® 7000BT SRI
Page 133
EAN-8
EAN-8 The following options apply to the EAN-8 symbology.
Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 bar codes.
Check Digit Transmission Enable this option to transmit the check Digit along with EAN-8 bar code data.
START/END STATE
BAR CODE
Disable EAN-8
Enable EAN-8
Don’t Send Check Digit
Send Check Digit
Product Reference Guide
6-17
Page 134
Symbologies
EAN-8, continued Expand EAN-8 to EAN-13, Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
START/END STATE
BAR CODE
Don’t Expand to EAN-13
Expand to EAN-13
6-18
PowerScan® 7000BT SRI
Page 135
EAN-8
EAN-8, continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-8 label must be decoded before it is accepted as good read.
START/END READS
BAR CODE
Minimum = 1 Read
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
6-19
Page 136
Symbologies
Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2digit, 5-digit and Code 128 add-ons. Supported options are: None, This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but still read the main portion of the bar code. 2 Digits, The scanner will optionally read 2-digit add-ons with the
UPC/EAN label. 5 Digits, The scanner will optionally read 5-digit add-ons with the
UPC/EAN label. Code 128 Add-on, The scanner will optionally read Code 128 addons with the UPC/EAN label.
Contact Customer Support for advanced programming of optional and conditional add-ons. NOTE
6-20
PowerScan® 7000BT SRI