Page 117

Chapter 6

Symbologies The scanner supports the following symbologies (bar code types). Options for each symbology are included in this chapter. ·UPC-A

·Pharmacode 39

·UPC-E

·Code 128 and EAN 128

·EAN-13

·Interleaved 2 of 5

·EAN-8

·Codabar

·RSS-14

·Code 93

·RSS Expanded

·Code 11

·RSS Limited

·MSI/Plessey

·Code 39

·Standard 2 of 5

2D Symbologies ·PDF 417

·Micro PDF 417

Factory Defaults, are indicated in bold text and are highlighted with yellow throughout this section.

Product Reference Guide

6-1

Page 118

Symbologies

UPC-A The following options apply to the UPC-A symbology.

Disable/Enable UPC-A When disabled, the scanner will not read UPC-A bar codes.

Check Digit Transmission Enable this option to transmit the check digit along with UPC-A bar code data.

Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

System Number Transmission This feature enables/disables transmission of UPC-A System Number.

6-2

PowerScan® 7000BT SRI

Page 119

UPC-A

UPC-A, continued START/END STATE

BAR CODE

Disable UPC-A

Enable UPC-A

Don’t Send Check Digit

Send Check Digit

Don’t Expand to EAN-13

Expand to EAN-13

Product Reference Guide

6-3

Page 120

Symbologies

UPC-A, continued START/END STATE

BAR CODE

Disable System Number Transmission

Enable System Number Transmission

6-4

PowerScan® 7000BT SRI

Page 121

UPC-A

UPC-A, continued UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPCA label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-5

Page 122

Symbologies

UPC-A, continued In-store Minimum Reads This feature specifies the minimum number of consecutive times an instore printed label must be decoded before it is accepted as good read.

START/END READS

BAR CODE

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

6-6

PowerScan® 7000BT SRI

Page 123

UPC-A

UPC-A, continued Add-On Timer This feature sets the period of time after a UPC-A label is decoded when optional add-on reading is enabled. START/END STATE

BAR CODE This item is used to set the timer value when optional add-ons are enabled. The selectable range is from 010 to 300 mSec in 10 mSec increments. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “AddOn Timer,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, AlphaNumeric Pad representing the disired timer setting. Exit programming mode by scanning the “END” bar code below.

Add-On Timer DEFAULT SETTING FOR THIS FEATURE: 007 (70 milliseconds)

Product Reference Guide

6-7

Page 124

Symbologies

UPC-E The following options apply to the UPC-E symbology.

Disable/Enable UPC-E When disabled, the scanner will not read UPC-E bar codes.

Check Digit Transmission Enable this option to transmit the check digit along with UPC-E bar code data.

System Number The System Number (SN) which is usually a zero (0) in the leading position can be optionally included (or not) with scanned bar code data.

Expand UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A.

Expand UPC-E to EAN13 Adds a leading zero to a UPC-E bar code which ‘expands’ the data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

6-8

PowerScan® 7000BT SRI

Page 125

UPC-E

UPC-E, continued START/END STATE

BAR CODE

Disable UPC-E

Enable UPC-E

Don’t Send Check Digit

Send Check Digit

Exclude System Number

Include System Number

Product Reference Guide

6-9

Page 126

Symbologies

UPC-E, continued START/END STATE

BAR CODE

Don’t Expand UPC-E to UPC-A

Expand UPC-E to UPC-A

Don’t Expand UPC-E to EAN-13

Expand UPC-E to EAN-13

6-10

PowerScan® 7000BT SRI