The text of a manual · part 13 of 31
PowerScan 7000BT SRI Linear Imager Product Reference Guide: Bluetooth Features, pages 109 to 116
Pages 109 to 116 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000BT
Page 109
Bluetooth (BT) Beeper Features
Bluetooth (BT) Beeper Features The settings in this section apply specifically to scanner beep indications associated with communications between the scanner and Base Station1 or other device it is linked to.
BT Beep Volume This option selects the volume (loudness/softness) of the Acknowledge (ACK) Label beep. START/END STATE
BAR CODE
BT Beep Volume = LOW
BT Beep Volume = MEDIUM
BT Beep Volume = HIGH
1. The Base Station does not include a beeper.
Product Reference Guide
5-9
Page 110
Bluetooth Features
BT Beep Duration Use this feature to set the duration of configurable BT-specific beeps. Settings are in increments of 10 milliseconds. START/END MODE
BAR CODE Sets the BT Beep Duration using a value from 001 to 255. Settings are in 10 millisecond increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set BT Beep Duration,” followed by the three characters (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 007 = 70 milliseconds 042 = 420 milliseconds 158 = 1.58 seconds 255 = 2.55 seconds DEFAULT SETTING FOR THIS FEATURE: 006 (80 milliseconds)
Set BT Beep Duration
5-10
PowerScan® 7000BT SRI
Page 111
Bluetooth (BT) Beeper Features
BT Beep Frequency This option selects the frequency (tone or pitch) of the Acknowledge (ACK) Label beep. START/END STATE
BAR CODE
BT Beep Frequency = LOW
BT Beep Frequency = MEDIUM
BT Beep Frequency = HIGH
Product Reference Guide
5-11
Page 112
Bluetooth Features
BT Disconnect Beep When enabled, this option allows the scanner to sound (beep) when the scanner disconnects from the Base Station due to out of range, low power, etc.
START/END STATE
BAR CODE
Disable Disconnect Beep
Enable Disconnect Beep
5-12
PowerScan® 7000BT SRI
Page 113
Bluetooth (BT) Beeper Features
BT ACK Label Beep This setting enables or disables the acknowledgement (ACK) beep that indicates a label has been sent to the Base Station, which has accepted the data and responded.
START/END STATE
BAR CODE
Disable ACK Label Beep
Enable ACK Label Beep
Product Reference Guide
5-13
Page 114
Bluetooth Features
BT Transmission Error Beep Enables or disables the transmission error Beep. This beep indicates a label has been sent to but not acknowledged by the Base Station (ACK Timeout occurred).
START/END STATE
BAR CODE
Disable Transmission Error Beep
Enable Transmission Error Beep
5-14
PowerScan® 7000BT SRI
Page 115
Bluetooth (BT) Beeper Features
BT In Cradle Chirp This feature enables or disables a “chirp” sound (a short, high-pitched beep) to indicate when the scanner is fully seated in position in the Base Station.
START/END STATE
BAR CODE
Disable In Cradle Chirp
Enable In Cradle Chirp
Product Reference Guide
5-15
Page 116
Bluetooth Features
BT Leash Beep This feature enables or disables the Leash Beep, which occurs upon disconnect. When enabled, the scanner will beep three times per second for the number of seconds defined in this setting to notify if a linked scanner is leaving the immediate vicinity of the Base Station1. This is especially useful in instances where a scanner might inadvertently have been placed in a bag or cart. A setting of 000 disables the Leash Beep.
START/END MODE
BAR CODE Sets the BT Leash Beep using a hex value from 000 to 255. Settings are in one second increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set BT Leash Beep,” followed by the three characters (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 000 = Disable Leash Beep 015 = 15 seconds 042 = 42 seconds 255 = 4 min 15 sec DEFAULT SETTING FOR THIS FEATURE: 000 (Disabled)
Set BT Leash Beep
1. The Base Station does not include a beeper. Only the scanner will beep to indicate.
5-16
PowerScan® 7000BT SRI