Page 109

Bluetooth (BT) Beeper Features

Bluetooth (BT) Beeper Features The settings in this section apply specifically to scanner beep indications associated with communications between the scanner and Base Station1 or other device it is linked to.

BT Beep Volume This option selects the volume (loudness/softness) of the Acknowledge (ACK) Label beep. START/END STATE

BAR CODE

BT Beep Volume = LOW

BT Beep Volume = MEDIUM

BT Beep Volume = HIGH

1. The Base Station does not include a beeper.

Product Reference Guide

5-9

Page 110

Bluetooth Features

BT Beep Duration Use this feature to set the duration of configurable BT-specific beeps. Settings are in increments of 10 milliseconds. START/END MODE

BAR CODE Sets the BT Beep Duration using a value from 001 to 255. Settings are in 10 millisecond increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set BT Beep Duration,” followed by the three characters (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 007 = 70 milliseconds 042 = 420 milliseconds 158 = 1.58 seconds 255 = 2.55 seconds DEFAULT SETTING FOR THIS FEATURE: 006 (80 milliseconds)

Set BT Beep Duration

5-10

PowerScan® 7000BT SRI

Page 111

Bluetooth (BT) Beeper Features

BT Beep Frequency This option selects the frequency (tone or pitch) of the Acknowledge (ACK) Label beep. START/END STATE

BAR CODE

BT Beep Frequency = LOW

BT Beep Frequency = MEDIUM

BT Beep Frequency = HIGH

Product Reference Guide

5-11

Page 112

Bluetooth Features

BT Disconnect Beep When enabled, this option allows the scanner to sound (beep) when the scanner disconnects from the Base Station due to out of range, low power, etc.

START/END STATE

BAR CODE

Disable Disconnect Beep

Enable Disconnect Beep

5-12

PowerScan® 7000BT SRI

Page 113

Bluetooth (BT) Beeper Features

BT ACK Label Beep This setting enables or disables the acknowledgement (ACK) beep that indicates a label has been sent to the Base Station, which has accepted the data and responded.

START/END STATE

BAR CODE

Disable ACK Label Beep

Enable ACK Label Beep

Product Reference Guide

5-13

Page 114

Bluetooth Features

BT Transmission Error Beep Enables or disables the transmission error Beep. This beep indicates a label has been sent to but not acknowledged by the Base Station (ACK Timeout occurred).

START/END STATE

BAR CODE

Disable Transmission Error Beep

Enable Transmission Error Beep

5-14

PowerScan® 7000BT SRI

Page 115

Bluetooth (BT) Beeper Features

BT In Cradle Chirp This feature enables or disables a “chirp” sound (a short, high-pitched beep) to indicate when the scanner is fully seated in position in the Base Station.

START/END STATE

BAR CODE

Disable In Cradle Chirp

Enable In Cradle Chirp

Product Reference Guide

5-15

Page 116

Bluetooth Features

BT Leash Beep This feature enables or disables the Leash Beep, which occurs upon disconnect. When enabled, the scanner will beep three times per second for the number of seconds defined in this setting to notify if a linked scanner is leaving the immediate vicinity of the Base Station1. This is especially useful in instances where a scanner might inadvertently have been placed in a bag or cart. A setting of 000 disables the Leash Beep.

START/END MODE

BAR CODE Sets the BT Leash Beep using a hex value from 000 to 255. Settings are in one second increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set BT Leash Beep,” followed by the three characters (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 000 = Disable Leash Beep 015 = 15 seconds 042 = 42 seconds 255 = 4 min 15 sec DEFAULT SETTING FOR THIS FEATURE: 000 (Disabled)

Set BT Leash Beep

1. The Base Station does not include a beeper. Only the scanner will beep to indicate.

5-16