Page 101
Chapter 5
Bluetooth Features This section contains features which are specific to radio communications between the scanner and Base Station or PC. When linked with a Base Station or PC, the scanner will read and decode bar codes (labels) and transmit them to the selected device via a Bluetooth radio.
Product Reference Guide
5-1
Page 102
Bluetooth Features
Auto Configuration Update When this feature is enabled, a scanner and its linked Base Station can automatically ensure they stay in sync with regard to configuration. This is accomplished by the linked scanner and Base Station comparing their configuration file check sum. If either is different, the Base Station will automatically update the scanner with its configuration. If the units are linked, any changes made to the Base Station configuration through the scan utility software will automatically be sent to the scanner at the completion of the programming session. By the same token, any changes made to the linked scanner’s configuration will automatically be transmitted to the Base Station when the scanner exits Programming Mode.
START/END STATE
BAR CODE
Disable Auto Configuration
Enable Auto Configuration
5-2
PowerScan® 7000BT SRI
Page 103
Auto Flash Memory Update
Auto Flash Memory Update Enable this feature to allow the Base Station to automatically update a linked scanner’s flash memory to the version in the Base Station.
START/END STATE
BAR CODE
Disable Auto Flash Update
Enable Auto Flash Update
Product Reference Guide
5-3
Page 104
Bluetooth Features
Non-Automatic Updates Use the following special programming bar code labels to perform a manual, one-time update to devices as listed.
Flash Update to Scanner Scan this programming bar code to copy the Base Station’s flash memory to the scanner. Use this method when the Auto Flash Memory Update feature is disabled and you want a one-time flash update to be performed.
Flash Update to Scanner
Copy Configuration to Scanner Scan the following label to copy the current Base Station configuration to the scanner. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed to the scanner.
Copy Configuration to Scanner
Copy Configuration to Base Station Scan the following label to copy the current scanner configuration to the Base Station. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed to the Base Station.
Copy Configuration to Base Station
5-4
PowerScan® 7000BT SRI
Page 105
Battery Charge Mode
Do Not Send Configuration to Scanner In instances where you do not want the Base Station to automatically update the scanner’s configuration (for example if your scanner contains a desired custom configuration but will temporarily be used with a Base Station containing an alternate configuration), scan the label below prior to linking the units to ensure the scanner configuration will not be overwritten by the Base Station.
Do Not Send Configuration to Scanner
Battery Charge Mode The Base Station’s ability to charge a Battery Pack (while installed in a scanner seated in the Base Station) can be controlled using this feature. START/END STATE
BAR CODE
Low Charge
High Charge
Charger Disabled
Product Reference Guide
5-5
Page 106
Bluetooth Features
ACK Timeout ACK Timeout configures a duration, selectable in 200-millisecond increments, for the scanner to wait for the Base Station to accept the data and respond with an ACK (acknowledge) or NAK (when data is in error). Upon expiration of the timeout, the scanner will emit a transmission error beep and return to its normal operating mode.
START/END MODE
BAR CODE Sets the ACK Timeout using a decimal value from 000 to 255. Settings are in 200 millisecond increments. A setting of 000 disables the timeout. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK Timeout,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 000 = Wait Forever 007 = 1.4 seconds 158 = 31.6 seconds 255 = 51 seconds DEFAULT SETTING FOR THIS FEATURE: 000 (Disable)
Set ACK Timeout
5-6
PowerScan® 7000BT SRI
Page 107
Poll Rate Timeout
Poll Rate Timeout During normal operation, the Base Station regularly signals (polls) for a response from the scanner in order to ensure the linked scanner is still in communication. This rate is set in 10 millisecond increments between polls. A value of 000 selects the minimum timeout1 of 1.25 milliseconds.
START/END MODE
BAR CODE Sets the Poll RateTimeout using a value from 000 to 100. Settings are in 10 millisecond increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Poll Rate Timeout,” followed by the three characters (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your setting. Exit programming mode by scanning the “START/END” bar code above. SETTINGS EXAMPLES: 000 = 1.25 milliseconds 007 = 70 milliseconds 012 = 120 milliseconds 100 = 1 second DEFAULT SETTING FOR THIS FEATURE: 002 (20 milliseconds)
Set Poll Timeout
1. Shortest time between polls. This is the fastest rate selectable.
Product Reference Guide
5-7
Page 108
Bluetooth Features
Transmit HACK This option allows you to choose when the HACK (Host Acknowledge) should be sent from the Base Station to the scanner. Choices are: •
OPTION #1, Send HACK as soon as the Base Station receives a label, or...
•
OPTION #2, Send HACK as soon as the Base Station completes transmission to the host.
START/END STATE
BAR CODE
HACK Option #1
HACK Option #2
5-8