The text of a manual · part 11 of 31
PowerScan 7000BT SRI Linear Imager Product Reference Guide: Data Editing, pages 92 to 100
Pages 92 to 100 of 272, from PowerScan 7000BT SRI Linear Imager Product Reference Guide
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000BT
Page 92
Data Editing
Label ID, continued START OPTION Set EAN-8 w/P5 Addon Label ID Character(s) Set EAN-8 w/C128 Addon Label ID Character(s)
Set EAN-13 Label ID Character(s)
BAR CODE
DEFAULT SETTING FOR THIS FEATURE: 4646 Hex (FF)
DEFAULT SETTING FOR THIS FEATURE: 4646 Hex (FF)
DEFAULT SETTING FOR THIS FEATURE: 46 Hex (F)
Set EAN-13 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 46 Hex (F) Set EAN-13 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 46 Hex (F) Set EAN-13 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 46 Hex (F) Set ISBN Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 49 Hex (I)
4-10
PowerScan® 7000BT SRI
Page 93
Label ID
Label ID, continued START OPTION Set GTIN Label ID Character(s)
Set GTIN w/P2 addon Label ID Character(s)
Set GTIN w/P5 addon Label ID Character(s)
Set GTIN w/C128 addon Label ID Character(s)
Set RSS-14 Label ID Character(s)
Set RSS-14 Composite Label ID Character(s)
BAR CODE
DEFAULT SETTING FOR THIS FEATURE:47 Hex (G)
DEFAULT SETTING FOR THIS FEATURE: 4732 Hex (G2)
DEFAULT SETTING FOR THIS FEATURE: 4735 Hex (G5)
DEFAULT SETTING FOR THIS FEATURE: 4738 Hex (G8)
DEFAULT SETTING FOR THIS FEATURE: 5234 Hex (R4)
DEFAULT SETTING FOR THIS FEATURE: 5234 Hex (R4)
Product Reference Guide
4-11
Page 94
Data Editing
Label ID, continued START OPTION Set RSS Expanded Label ID Character(s)
Set RSS Expanded Composite Label ID Character(s)
Set RSS Limited Label ID Character(s)
Set RSS Limited Composite Label ID Character(s)
Set Code 39 Label ID Character(s)
4-12
BAR CODE
DEFAULT SETTING FOR THIS FEATURE: 5258 Hex (RX)
DEFAULT SETTING FOR THIS FEATURE: 5258 Hex (RX)
DEFAULT SETTING FOR THIS FEATURE: 524C Hex (RL)
DEFAULT SETTING FOR THIS FEATURE: 524C Hex (RL)
DEFAULT SETTING FOR THIS FEATURE: 2A Hex (*)
PowerScan® 7000BT SRI
Page 95
Label ID
Label ID, continued START OPTION
BAR CODE
Set Pharmacode 39 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 41 Hex (A) Set Code 128 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 23 Hex (#) Set I 2 of 5 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 69 Hex (i) Set Codabar Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE:25 Hex (%) Set Code 93 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 26 Hex (&)
Set Code 11 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: 4345 Hex (CE)
Product Reference Guide
4-13
Page 96
Data Editing
Label ID, continued START OPTION Set MSI/Plessey Label ID Character(s)
Set Std 2 of 5 Label ID Character(s)
Set PDF 417 Label ID Character(s)
BAR CODE
DEFAULT SETTING FOR THIS FEATURE: 40 Hex (@)
DEFAULT SETTING FOR THIS FEATURE: 69 Hex (i)
DEFAULT SETTING FOR THIS FEATURE: 50 Hex (P)
Set Micro PDF 417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 6D50 Hex (mP) END
4-14
PowerScan® 7000BT SRI
Page 97
Label ID
Case Conversion This feature can convert scanned bar code data to either all lower case or all upper case characters. Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE
START MODE
BAR CODE
Disable
Convert to Upper Case
Convert to Lower Case
END
Product Reference Guide
4-15
Page 98
Data Editing
Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF. With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22. The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Scan the START bar code. 2. Scan the Character Conversion bar code. 3. Determine the desired string. Sixteen positions must be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string. 4. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex characters determined in the previous step. 5. Scan the END bar code to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode. NOTE
Scan the END bar code to exit programming mode.
4-16
PowerScan® 7000BT SRI
Page 99
Label ID
Character Conversion, continued START MODE
Character Conversion
BAR CODE
DEFAULT SETTING FOR THIS FEATURE: FFFFFFFFFFFFFFFF Hex (no conversion)
END
Product Reference Guide
4-17
Page 100
Data Editing
NOTES
4-18
PowerScan® 7000BT SRI