Page 83

Chapter 4

Data Editing Data Editing Overview It is not recommended to use these features with IBM or Wand Emulation interfaces. CAUTION

When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 4-1 shows the available elements you can add to a message string: Figure 4-1. Breakdown of a Message String Label ID Transmission: Enable this option to transmit the Label ID you configure for the scanned symbology.

Prefix

Label ID

OR...

AIM ID

Bar Code Data

Label ID

Suffix

AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII)

Product Reference Guide

4-1

Page 84

Data Editing

Please Keep In Mind... •

Modifying a message string is not a mandatory requirement. Data editing is a sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.

•

A prefix or suffix may be applied (reference the Symbologies chapter for these settings) across all symbologies (set via the Global features in this chapter).

•

You can add any character from the ASCII Chart (from 00-FF hex) on the inside back cover of this manual as a prefix, suffix or Label ID.

•

Enter prefixes and suffixes in the order in which you want them to appear on the output.

Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/or as a suffix (in a position following the bar code data) as indicated in Figure 4-2. Figure 4-2. Prefix and Suffix Positions

OR... Prefix

Label ID

AIM ID

Bar Code Data

Label ID

Suffix

00 - 20 Characters (ASCII)

AND OR

4-2

PowerScan® 7000BT SRI

Page 85

Global Prefix/Suffix

Global Prefix/Suffix, continued Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 2. Scan the START bar code. 3. Scan the SET PREFIX bar code. 4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from Appendix C, Alpha-Numeric Pad. 5. Scan the END bar code to exit Programming Mode. If less than the expected string of 20 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode. NOTE

6. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: $12345

Product Reference Guide

4-3

Page 86

Data Editing

Global Prefix/Suffix, continued START MODE

BAR CODE Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the alpha-numeric characters from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character(s). Reference the section, Example: Setting a Prefix, for more information. Exit programming mode by scanning the “END” bar code below (scan “END” twice if less than 20 characters have been selected). DEFAULT SETTING FOR THIS FEATURE: 00 Hex (None)

Set Prefix

Set Suffix

END

4-4

PowerScan® 7000BT SRI

Page 87

AIM ID

AIM ID AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: •

A close brace character (ASCII ‘]’), followed by...

•

A code character (see the table below), followed by

•

A modifier character (the modifier character is symbol dependent) SYMBOLOGY

CHAR

SYMBOLOGY

CHAR

UPC/EAN

E

MSI/Plessey

M

Code 39

A

PDF 417 & Micro PDF 417

L

Codabar

F

RSS (RSS-14, RSS Expanded, RSS Limited)

e

Interleaved.2 of 5

I

Standard 2 of 5

S

Code 93

G

ISBN

Xa

Code 128/EAN 128

C a. ISBN (X with a 0 modifier character)

Figure 4-3. AIM ID

Prefix

Label ID

AIM ID

Product Reference Guide

Bar Code Data

Label ID

Suffix

4-5

Page 88

Data Editing

AIM ID, continued START STATE

BAR CODE

Disable AIM ID

Enable AIM ID

END

4-6

PowerScan® 7000BT SRI

Page 89

Label ID

Label ID A Label ID is a customizable code of up to two ASCII characters (00FF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types, see the previous feature, AIM ID. To configure a Label ID: 1. Scan the START bar code. 2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar code. 3. Scan a bar code to select the symbology for which you wish to configure a custom Label ID. 4. Determine the desired character(s) (you may choose either one or two) which will represent the Label ID for the selected symbology. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. 5. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex characters determined in the previous step. For the example given, the characters ‘0’, ‘0’, ‘3’ and ‘D’ would be scanned. The two zeros scanned (‘0’, ‘0’) represent a selection of “no character,” since this option allows for two Label ID characters. (Pad with zeros to enter four hex characters.) 6. Scan the END bar code to exit programming mode. Figure 4-4. Label ID Position Options

Prefix

Label ID

Aim ID

Bar Code Data

Label ID

Suffix

OR

Product Reference Guide

4-7

Page 90

Data Editing

Label ID, continued START OPTION

BAR CODE

Label ID Transmission: Disable

Label ID Position: Before Bar Code Data

Label ID Position: After Bar Code Data

Set UPC-A Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 41 Hex (A) Set UPC-A w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 41 Hex (A) Set UPC-A w/P5 Addon Label ID Character(s)

4-8

DEFAULT SETTING FOR THIS FEATURE: 41 Hex (A)

PowerScan® 7000BT SRI

Page 91

Label ID

Label ID, continued START OPTION

BAR CODE

Set UPC-A w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 41 Hex (A) Set UPC-E Label ID Character(s) Set UPC-E w/P2 Addon Label ID Character(s) Set UPC-E w/P5 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: 45 Hex (E)

DEFAULT SETTING FOR THIS FEATURE: 45 Hex (E)

DEFAULT SETTING FOR THIS FEATURE: 45 Hex (E)

Set UPC-E w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 45 Hex (E) Set EAN-8 Label ID Character(s)

Set EAN-8 w/P2 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: 4646 Hex (FF)

DEFAULT SETTING FOR THIS FEATURE: 4646 Hex (FF)

Product Reference Guide

4-9