The text of a manual · part 15 of 20
Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 135 to 142
Pages 135 to 142 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1400i
Page 135
MSI/Plessey
MSI/Plessey, continued Minimum Reads This feature specifies the minimum number of consecutive times an MSI/Plessey label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-61
Page 136
Symbologies
Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology.
Disable/Enable Standard 2 of 5 When this feature is disabled, the scanner will not read Standard 2 of 5 barcodes. START / END PROGRAMMING BAR CODES Disable Std 2 of 5 DEFAULT
Enable Std 2 of 5
Check Digit Verification When enabled, the scanner will verify the check digit of the labels. START / END PROGRAMMING BAR CODES Disable Check Digit Verification DEFAULT
Enable Check Digit Verification
5-62
Magellan® 1400i
Page 137
Standard 2 of 5
Standard 2 of 5, continued Check Digit Transmit When this option is enabled, the scanner will transmit the check digit. START / END PROGRAMMING BAR CODES
Disable Check Digit Transmission
Enable Check Digit Transmission DEFAULT
Product Reference Guide
5-63
Page 138
Symbologies
Standard 2 of 5, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Standard 2 of 5 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT
Fixed Length Decoding
5-64
Magellan® 1400i
Page 139
Standard 2 of 5
Standard 2 of 5, continued Standard 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Standard 2 of 5 barcodes, all check and data characters are included in the length calculations. NOTE
4. Scan the END barcode. START / END PROGRAMMING BAR CODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 008
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050
Product Reference Guide
5-65
Page 140
Symbologies
Standard 2 of 5, continued Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 barcodes. When parts of a Standard 2 of 5 label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met.
Only functions when Fixed Length Decoding is enabled. NOTE
START / END PROGRAMMING BAR CODES Disable Std 2 of 5 Stitching DEFAULT
Enable Std 2 of 5 Stitching
5-66
Magellan® 1400i
Page 141
Standard 2 of 5
Standard 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-67
Page 142
Symbologies
NOTES
5-68
Magellan® 1400i