Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 20

Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: 2D Symbologies & Advanced Decoding Features

Pages 143 to 152 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 1400i

Page 143

2D Symbologies & Advanced Decoding Features The features in this section are available ONLY for models with 2D features activated. NOTE

Product Reference Guide

6-1

Page 144

2D Symbologies & Advanced Decoding Features

2D Symbologies The scanner supports the following 2D symbologies (barcode types): PDF 417 and Datamatrix. Options for each symbology are included in this addendum. Factory Defaults - for the std. RS-232 interface are indicated in bold text throughout.

PDF 417 Disable/Enable PDF 417 When disabled, the scanner will not read PDF 417 barcodes. START / END PROGRAMMING BARCODES

Disable PDF 417

Enable PDF 417

6-2

Magellan® 1400i

Page 145

2D Symbologies

PDF 417, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the PDF 417 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the minimum length by following the PDF 417 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the PDF 417 Length 1, Length 2 Programming Instructions below.

START / END PROGRAMMING BARCODES

Variable Length Decoding

Fixed Length Decoding

Product Reference Guide

6-3

Page 146

2D Symbologies & Advanced Decoding Features

PDF 417, continued PDF 417 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Alpha-Numeric Pad and scan the four hex digits representing the length in hexidecimal notation. For PDF 417 barcodes, only the data characters are included in the length calculations. NOTE

Scan the END barcode.

START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 01 (0X0001)

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 2710 (0x0A96)

6-4

Magellan® 1400i

Page 147

2D Symbologies

PDF 417, continued Minimum Reads This feature specifies the minimum number of consecutive times a PDF 417 label must be decoded before it is accepted as good read.

START / END PROGRAMMING BARCODES

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-5

Page 148

2D Symbologies & Advanced Decoding Features

Datamatrix Disable/Enable Datamatrix When disabled, the scanner will not read Datamatrix barcodes. START / END PROGRAMMING BARCODES

Disable Datamatrix

Enable Datamatrix

6-6

Magellan® 1400i

Page 149

2D Symbologies

Datamatrix, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Datamatrix Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the minimum length by following the Datamatrix Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

START / END PROGRAMMING BARCODES

Variable Length Decoding

Fixed Length Decoding

Product Reference Guide

6-7

Page 150

2D Symbologies & Advanced Decoding Features

Datamatrix, continued Datamatrix Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Alpha-Numeric Pad and scan the four hex digits representing the length in hexidecimal notation. For Datamatrix barcodes, only the data characters are included in the length calculations. NOTE

Scan the END barcode.

START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 1 (0x0001)

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 800 (0x0320)

6-8

Magellan® 1400i

Page 151

2D Symbologies

Datamatrix, continued Minimum Reads This feature specifies the minimum number of consecutive times a Datamatrix label must be decoded before it is accepted as good read.

START / END PROGRAMMING BARCODES

Minimum = 1 Read

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

6-9

Page 152

2D Symbologies & Advanced Decoding Features

Image Capture This function is ONLY available for scanners having a button. Image capture requires that the scanner use the Standard RS-232 or USB COM interface ONLY. NOTE The scanner reverts to default reading mode after image capture and transfer.

How to Capture an Image To initiate an Image Capture, scan the IMAGE CAPTURE label below, and press the button. A targeting “pointer” will be illuminated while the button is pressed. Upon release of the button, the image is captured and transmitted to the host. If the button is not pushed within 30 seconds, the scanner will return to barcode reading (scanning) mode.

IMAGE CAPTURE

Captured Image Format Images are captured as 752 x 480 JPEG format with a pre-defined compression ratio, and are displayed via the host application software.

6-10

Magellan® 1400i