Page 125

Codabar

Codabar, continued Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

5-51

Page 126

Symbologies

Code 93 The following options apply to the Code 93 symbology.

Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 barcodes. START / END PROGRAMMING BAR CODES Disable Code 93 DEFAULT

Enable Code 93

5-52

Magellan® 1400i

Page 127

Code 93

Code 93, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Code 93 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 93 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Code 93 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Code 93 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

5-53

Page 128

Symbologies

Code 93, continued Code 93 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Code 93 barcodes, only the data characters are included in the length calculations. NOTE

4. Scan the END barcode. START / END PROGRAMMING BAR CODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 001

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050

5-54

Magellan® 1400i

Page 129

Code 93

Code 93, continued Code 93 Stitching Enables/disables stitching for Code 93 barcodes. When parts of a Code 93 label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. START / END PROGRAMMING BAR CODES Disable Code 93 Stitching DEFAULT

Enable Code 93 Stitching

Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

5-55

Page 130

Symbologies

MSI/Plessey The following options apply to the MSI/Plessey symbology.

Disable/Enable MSI/Plessey When this feature is disabled, the scanner will not read MSI/Plessey barcodes. START / END PROGRAMMING BAR CODES Disable MSI/Plessey DEFAULT

Enable MSI/Plessey

Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified. START / END PROGRAMMING BAR CODES Disable Check Digit Verification DEFAULT

Enable Check Digit Verification

5-56

Magellan® 1400i

Page 131

MSI/Plessey

MSI/Plessey, continued Check Digit Transmit When this option is enabled, the scanner will transmit one-digit or two-digit check digits, depending upon the setting for check digit verification. START / END PROGRAMMING BAR CODES

Disable Check Digit Transmission

Enable Check Digit Transmission DEFAULT

Number of Check Characters Specifies number of MSI/Plessey check characters to be calculated and verified START / END PROGRAMMING BAR CODES 1 Check Character DEFAULT

2 Check Characters

Product Reference Guide

5-57

Page 132

Symbologies

MSI/Plessey, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the MSI/Plessey Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the MSI/Plessey Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the MSI/Plessey Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the MSI/Plessey Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT ³

Fixed Length Decoding

5-58

Magellan® 1400i

Page 133

MSI/Plessey

MSI/Plessey, continued MSI/Plessey Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For MSI/Plessey barcodes, all check and data characters are included in the length calculations. NOTE

4. Scan the END barcode. START / END PROGRAMMING BAR CODES Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 004

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 016

Product Reference Guide

5-59

Page 134

Symbologies

MSI/Plessey, continued MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey barcodes. When parts of an MSI/Plessey label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met.

Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BAR CODES Disable MSI/Plessey Stitching DEFAULT

Enable MSI/Plessey Stitching

5-60