Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 20

Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 115 to 124

Pages 115 to 124 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 1400i

Page 115

Interleaved 2 of 5

Interleaved 2 of 5, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

5-41

Page 116

Symbologies

Interleaved 2 of 5, continued Interleaved 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation.

NOTE

For Interleaved 2 of 5 barcodes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.

4. Scan the END barcode. START / END PROGRAMMING BAR CODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 006

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050

5-42

Magellan® 1400i

Page 117

Interleaved 2 of 5

Interleaved 2 of 5, continued Interleaved 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an Interleaved 2 of 5 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met.

Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BAR CODES Disable Interleaved 2 of 5 Stitching DEFAULT

Enable Interleaved 2 of 5 Stitching

Product Reference Guide

5-43

Page 118

Symbologies

Interleaved 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

5-44

Magellan® 1400i

Page 119

Codabar

Codabar The following options apply to the Codabar symbology.

Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar barcodes. START / END PROGRAMMING BAR CODES Disable Codabar DEFAULT

Enable Codabar

Check Character Verification When enabled, the scanner will verify the check character of the labels. START / END PROGRAMMING BAR CODES Disable Check Char Verification DEFAULT

Enable Check Char Verification

Product Reference Guide

5-45

Page 120

Symbologies

Codabar, continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BAR CODES

Disable Check Char Transmission

Enable Check Char Transmission DEFAULT

5-46

Magellan® 1400i

Page 121

Codabar

Codabar, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Codabar Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Codabar Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

5-47

Page 122

Symbologies

Codabar, continued Codabar Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For Codabar barcodes, all start, stop, check and data characters are included in the length calculations. NOTE

4. Scan the END barcode. START / END PROGRAMMING BAR CODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 003

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050

Quiet Zones This feature enable/disables the requirement that quiet zones must be present for Codabar barcodes. START / END PROGRAMMING BAR CODES Don’t require Quiet Zones DEFAULT

Require Quiet Zones

5-48

Magellan® 1400i

Page 123

Codabar

Codabar, continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application. START / END PROGRAMMING BAR CODES

Start/Stop Type: ABCD/TN*E

Start/Stop Type: ABCD/ABCD

Start/Stop Type: abcd/tn*e

Start/Stop Type: abcd/abcd DEFAULT

Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below. START / END PROGRAMMING BAR CODES

Disable Start/Stop Char Transmission

Enable Start/Stop Char Transmission DEFAULT

Product Reference Guide

5-49

Page 124

Symbologies

Codabar, continued Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match. START / END PROGRAMMING BAR CODES Disable Start/Stop Char Match DEFAULT

Enable Start/Stop Char Match

Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met.

Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BAR CODES Disable Codabar Stitching DEFAULT

Enable Codabar Stitching

5-50

Magellan® 1400i