For the Datalogic 1100i

Page 59

Interface Features

IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for USB-OEM; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.

START / END PROGRAMMING BARCODES Disable Convert to Code 39 DEFAULT

Enable Convert to Code 39

Product Reference Guide

51

Page 60

Interface Related Features

Keyboard Wedge and

USB Keyboard As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware. All of the options in this section apply to the Keyboard Wedge, however, only some apply to USB Keyboard. NOTE Keyboard Layout

The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual. START / END PROGRAMMING BARCODES USA DEFAULT

Belgium

Britain

Denmark

France

Germany

52

MagellanTM 1100i

Page 61

Interface Features

Keyboard Wedge, cont. START / END PROGRAMMING BARCODES Italy

Norway

Portugal

Spain

Sweden

Switzerland

Japan 106 Key

Hungary

Czech Republic

Product Reference Guide

53

Page 62

Interface Related Features

Keyboard Wedge, cont. START / END PROGRAMMING BARCODES Slovakia

Romania

Croatia

Poland

Caps Lock State Specifies the format in which the scanner sends character data. START / END PROGRAMMING BARCODES Disable Caps Lock DEFAULT

Caps Lock “ON”

Shift Lock “ON”

54

MagellanTM 1100i

Page 63

Interface Features

Keyboard Wedge, cont. Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE

All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.

START / END PROGRAMMING BARCODES Disable Power-on Simulation DEFAULT

Enable Power-on Simulation

Product Reference Guide

55

Page 64

Interface Related Features

Control Characters

Specifies how the scanner transmits ASCII control characters to the host. Choices are: •

Disable Control Characters

•

Enable transmission of control characters to host

•

Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference Appendix E, Keyboard Function Key Mappings.)

START / END PROGRAMMING BARCODES Disable Control Characters DEFAULT

Enable Transmission of Control Characters

Enable Function Key Mapping

56

MagellanTM 1100i

Page 65

Interface Features

Keyboard Wedge, cont. Wedge Quiet Interval This feature does not apply to the USB Keyboard interface. NOTE

Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host. START / END PROGRAMMING BARCODES Selectable from 001 to 100 in 10 msec increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the “START/END” bar code above. DEFAULT SETTING FOR THIS FEATURE: 010 (100 msec) Set Wedge Quiet Interval

Product Reference Guide

57

Page 66

Interface Related Features

Keyboard Wedge, cont. Intercharacter Delay START / END PROGRAMMING BARCODES One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable from 00 to 99 in 10msec increments. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Intercharacter Delay,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the “START/END” barcode above/ DEFAULT SETTING FOR THIS FEATURE: 00 (No Delay) Set Intercharacter Delay

USB COM Interface Set-up This interface uses the Microsoft Windows USB COM driver. Before plugging your reader into the host PC, please ensure you have already copied the DLS_EUG_CDC_ACM.inf file provided by Datalogic to your PC and the reader’s interface is set to USB COM. 1. When you first plug the scanner into the PC, Windows will bring up the “Found New Hardware Wizard.” Select “Install from a list” and click on “Next.” 2. Click on “Include this location in the search” and enter the path where the file DLS_EUG_CDC_ACM.inf file is stored. Click on “Next.” 3. If a message appears that says the software has not passed Windows logo testing, press “Continue” anyway. 4. Click on “Finish.” 5. Once the install is complete, reboot the PC.

58

MagellanTM 1100i