The text of a manual · part 9 of 26
Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Interface Related Features, pages 59 to 66
Pages 59 to 66 of 208, from Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1100i
Page 59
Interface Features
IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for USB-OEM; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.
START / END PROGRAMMING BARCODES Disable Convert to Code 39 DEFAULT
Enable Convert to Code 39
Product Reference Guide
51
Page 60
Interface Related Features
Keyboard Wedge and
USB Keyboard As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware. All of the options in this section apply to the Keyboard Wedge, however, only some apply to USB Keyboard. NOTE Keyboard Layout
The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual. START / END PROGRAMMING BARCODES USA DEFAULT
Belgium
Britain
Denmark
France
Germany
52
MagellanTM 1100i
Page 61
Interface Features
Keyboard Wedge, cont. START / END PROGRAMMING BARCODES Italy
Norway
Portugal
Spain
Sweden
Switzerland
Japan 106 Key
Hungary
Czech Republic
Product Reference Guide
53
Page 62
Interface Related Features
Keyboard Wedge, cont. START / END PROGRAMMING BARCODES Slovakia
Romania
Croatia
Poland
Caps Lock State Specifies the format in which the scanner sends character data. START / END PROGRAMMING BARCODES Disable Caps Lock DEFAULT
Caps Lock “ON”
Shift Lock “ON”
54
MagellanTM 1100i
Page 63
Interface Features
Keyboard Wedge, cont. Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.
START / END PROGRAMMING BARCODES Disable Power-on Simulation DEFAULT
Enable Power-on Simulation
Product Reference Guide
55
Page 64
Interface Related Features
Control Characters
Specifies how the scanner transmits ASCII control characters to the host. Choices are: •
Disable Control Characters
•
Enable transmission of control characters to host
•
Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference Appendix E, Keyboard Function Key Mappings.)
START / END PROGRAMMING BARCODES Disable Control Characters DEFAULT
Enable Transmission of Control Characters
Enable Function Key Mapping
56
MagellanTM 1100i
Page 65
Interface Features
Keyboard Wedge, cont. Wedge Quiet Interval This feature does not apply to the USB Keyboard interface. NOTE
Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host. START / END PROGRAMMING BARCODES Selectable from 001 to 100 in 10 msec increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the “START/END” bar code above. DEFAULT SETTING FOR THIS FEATURE: 010 (100 msec) Set Wedge Quiet Interval
Product Reference Guide
57
Page 66
Interface Related Features
Keyboard Wedge, cont. Intercharacter Delay START / END PROGRAMMING BARCODES One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable from 00 to 99 in 10msec increments. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Intercharacter Delay,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the “START/END” barcode above/ DEFAULT SETTING FOR THIS FEATURE: 00 (No Delay) Set Intercharacter Delay
USB COM Interface Set-up This interface uses the Microsoft Windows USB COM driver. Before plugging your reader into the host PC, please ensure you have already copied the DLS_EUG_CDC_ACM.inf file provided by Datalogic to your PC and the reader’s interface is set to USB COM. 1. When you first plug the scanner into the PC, Windows will bring up the “Found New Hardware Wizard.” Select “Install from a list” and click on “Next.” 2. Click on “Include this location in the search” and enter the path where the file DLS_EUG_CDC_ACM.inf file is stored. Click on “Next.” 3. If a message appears that says the software has not passed Windows logo testing, press “Continue” anyway. 4. Click on “Finish.” 5. Once the install is complete, reboot the PC.
58
MagellanTM 1100i