Page 49

Interface Features

Intercharacter Delay, cont. START / END PROGRAMMING BARCODES Interchar Delay = 80 msec

Interchar Delay = 90 msec

Software Flow Control Disables/Enables software control using XON/XOFF characters. START / END PROGRAMMING BARCODES Disable Software Flow Control DEFAULT

Enable Software Flow Control

Product Reference Guide

41

Page 50

Interface Related Features

RS-232 Interface Features, cont. Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the barcode data that has just been scanned to the host. START / END PROGRAMMING BARCODES Host Echo Quiet Interval = 0msec

Host Echo Quiet Interval = 10msec DEFAULT

Host Echo Quiet Interval = 20msec

Host Echo Quiet Interval = 30msec

Host Echo Quiet Interval = 40msec

Host Echo Quiet Interval = 50msec

Host Echo Quiet Interval = 60msec

Host Echo Quiet Interval = 70msec

42

MagellanTM 1100i

Page 51

Interface Features

Host Echo Quiet Interval, cont. START / END PROGRAMMING BARCODES Host Echo Quiet Interval = 80msec

Host Echo Quiet Interval = 90msec

Host Echo Quiet Interval = 100msec

Signal Voltage: Normal/TTL Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.

START / END PROGRAMMING BARCODES Signal Voltage: Normal RS-232 DEFAULT

Signal Voltage: TTL

Product Reference Guide

43

Page 52

Interface Related Features

Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex). START / END PROGRAMMING BARCODES Enable Beep on ASCII BEL DEFAULT

Disable Beep on ASCII BEL

Beep on Not on File Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host. START / END PROGRAMMING BARCODES Disable Beep on Not On File

Enable Beep on Not On File DEFAULT

44

MagellanTM 1100i

Page 53

Interface Features

ACK NAK Options This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are: •

Disable

•

Enable for label transmission, the scanner expects an ACK/NAK response from the host when a label is sent

•

Enable for host-command acknowledge, the scanner will respond with ACK/NAK when the host sends a command

•

Enable for label transmission and host-command acknowledge

START / END PROGRAMMING BARCODES Disable ACK NAK DEFAULT

Enable ACK NAK for Transmission

Enable ACK NAK for host command acknowledge

Enable ACK NAK for transmission and host command

Product Reference Guide

45

Page 54

Interface Related Features

RS-232 Interface Features, cont., cont. ACK Character

START / END PROGRAMMING BARCODES Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 006

Set ACK Character

NAK Character

START / END PROGRAMMING BARCODES Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 021 Set NAK Character

46

MagellanTM 1100i

Page 55

Interface Features

RS-232 Interface Features, cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired.

START / END PROGRAMMING BARCODES

Disable Retry on ACK NAK Timeout

Enable Retry on ACK NAK Timeout DEFAULT

ACK NAK Timeout Value

START / END PROGRAMMING BARCODES This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. 000 = Infinite timeout 001 - 075 = Timeout in 200-millisecond increments To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK NAK Timeout Value,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired value. Exit programming mode by again scanning the “START/END” barcode above. DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec) Set ACK NAK Timeout Value

Product Reference Guide

47

Page 56

Interface Related Features

RS-232 Interface Features, cont. ACK NAK Retry Count START / END PROGRAMMING BARCODES This feature sets the number of times for the scanner to retry a label transmission under a retry condition. 000 = No retry 001 - 254 = Retry for the specified number of times 255 = Retry forever To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set ACK NAK Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired retry count. Exit programming mode by again scanning the “START/END” barcode above DEFAULT SETTING FOR THIS FEATURE: 003

Set ACK NAK Timeout Value

48

MagellanTM 1100i

Page 57

Interface Features

RS-232 Interface Features, cont. ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data) START / END PROGRAMMING BARCODES Ignore Errors Detected DEFAULT

Process error as valid ACK character

Process error as valid NAK character

Product Reference Guide

49

Page 58

Interface Related Features

RS-232 Interface Features, cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure.

START / END PROGRAMMING BARCODES

Disable Transmission Error Indication

Enable Transmission Error Indication DEFAULT

USB-OEM Interface Features USB-OEM Device usage The USB-OEM protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: •

Table Top Scanner

•

Handheld Scanner

START / END PROGRAMMING BARCODES Configure as Table Top Scanner DEFAULT

Configure as Handheld Scanner

50

MagellanTM 1100i