Page 39

Chapter 3

Interface Related Features At the time of this writing, the reader supports the interfaces listed in Table 3-1. Select the desired interface type from the table, then reference the page number given for the customizable features section associated with each interface. See Table 3-2 for a description of each Keyboard Wedge interface type (A through Y as listed). Table 3-1. Interfaces Supported RS-232 Page Keyboard Wedge

3-34

RS-232 Standard

3-33

Keyboard Wedge Aa

3-34

RS-232 Wincor-Nixdorf

3-33

Keyboard Wedge Ba

3-34

Keyboard Wedge Ca

3-34

IBM IBM 4683 Port 5B

3-33

Keyboard Wedge Da

3-34

IBM 4683 Port 9B

3-33

Keyboard Wedge Ea

3-34

IBM 4683 Port 17

3-33

Keyboard Wedge Fa

3-34

Keyboard Wedge Ga

3-34

USB USB-OEM

3-33

Keyboard Wedge Ha

3-34

USB Keyboard

3-33

Keyboard Wedge Ia

3-34

USB COM Interface

3-33

Keyboard Wedge Ja

3-34 a. Consult Table 3-2 for more information regarding keyboard interface types.

The correct interface cable is included for the reader interface type you ordered. NOTE

Product Reference Guide

31

Page 40

Interface Related Features

Table 3-2. Keyboard Wedge Interface Reference I/F PCs Supported Type A PC/XT w/Alternate Key Encoding AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ B Alternate Key Encoding C PS/2 25 and 30 w/Alternate Key Encoding D PC/XT w/Standard Key Encoding AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ E Standard Key Encoding F PS/2 25 and 30 w/Standard Key Encoding G IBM 3xxx w/122 keyboard H IBM 3xxx w/102 keyboard I PS/55 5530T w/104 keyboard J NEC 9801

NOTE

32

Reference Appendix E, Keyboard Function Key Mappings for more information about keyboards.

MagellanTM 1100i

Page 41

Interface Selection

Interface Selection START / END PROGRAMMING BARCODES RS-232 Standard

RS-232 Wincor-Nixdorf

IBM 4683 Port 5B

IBM 4683 Port 9B

IBM 4683 Port 17

USB-OEM

USB Keyboard

USB COM Interface

Product Reference Guide

33

Page 42

Interface Related Features

Interface Selection, cont. START / END PROGRAMMING BARCODES Keyboard Wedge A

Keyboard Wedge B

Keyboard Wedge C

Keyboard Wedge D

Keyboard Wedge E

Keyboard Wedge F \

Keyboard Wedge G

Keyboard Wedge H ³

0 0 0 1 3 2

Keyboard Wedge I

Keyboard Wedge J

34

MagellanTM 1100i

Page 43

Interface Features

Interface Features Obey/Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface, select Obey Host Commands.

START / END PROGRAMMING BARCODES Obey Host Commands DEFAULT

Ignore Host Commands

Product Reference Guide

35

Page 44

Interface Related Features

Interface Features, cont. Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a barcode, the scanner can continue to read a new barcode while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first barcode must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new barcode can be read while data from the first barcode is transmitted.

When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered.

START / END PROGRAMMING BARCODES Host Transmission Buffers = 1

Host Transmission Buffers = 2 DEFAULT

36

MagellanTM 1100i

Page 45

Interface Features

RS-232 Interface Features START / END PROGRAMMING BARCODES 1200 Baud

2400 Baud

4800 Baud

9600 Baud DEFAULT

19200 Baud

38400 Baud

57600 Baud

115200 Baud

Product Reference Guide

37

Page 46

Interface Related Features

RS-232 Interface Features, cont. START / END PROGRAMMING BARCODES 7 Data Bits

8 Data Bits DEFAULT

1 Stop Bit DEFAULT

2 Stop Bits

Parity = None DEFAULT

Parity = Even

Parity = Odd

38

MagellanTM 1100i

Page 47

Interface Features

RS-232 Interface Features, cont. Hardware Flow Control Disable Hardware Control - The scanner transmits to the host regardless of any activity on the CTS line. Enable CTS Flow Control - The CTS signal controls transmission of data to the host. Enable CTS Scan Control - The CTS line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.

START / END PROGRAMMING BARCODES Disable Hardware Control DEFAULT

Enable CTS Flow Control

Enable CTS Scan Control

Product Reference Guide

39

Page 48

Interface Related Features

RS-232 Interface Features, cont. Intercharacter Delay This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. START / END PROGRAMMING BARCODES Inter-Char Delay = No Delay DEFAULT

Interchar Delay = 10 msec

Interchar Delay = 20 msec

Interchar Delay = 30 msec

Interchar Delay = 40 msec

Interchar Delay = 50 msec

Interchar Delay = 60 msec

Interchar Delay = 70 msec

40