Page 67
Chapter 4
Data Editing Data Editing Overview It is not recommended to use these features with IBM interfaces. CAUTION
When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 4-1 shows the available elements you can add to a message string: Figure 4-1. Breakdown of a Message String Label ID Transmission: Enable this option to transmit the Label ID you configure for the scanned symbology.
OR... Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII)
Please Keep In Mind... •
Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
•
A prefix or suffix may be applied (reference the Symbologies chapter for these settings) across all symbologies (set via the Global features in this chapter).
•
You can add any character from the ASCII Chart (from 00-7F) on the inside back cover of this manual as a prefix, suffix or Label ID.
•
Enter prefixes and suffixes in the order in which you want them to appear on the output.
Product Reference Guide
59
Page 68
Data Editing
Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/or as a suffix (in a position following the barcode data) as indicated in Figure 4-2. Figure 4-2. Prefix and Suffix Positions
OR... Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
00 - 20 Characters (ASCII)
AND OR Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned barcode data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 2. Scan the START barcode. 3. Scan the SET PREFIX barcode. 4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ barcodes from Appendix C, AlphaNumeric Pad. 5. Scan the END barcode once to finish the string, then scan END again to exit Programming Mode. If all 20 characters will be used in the prefix or suffix, do not scan the END barcode to finish the string. It is done automatically. NOTE
6. The resulting message string would appear as follows: Scanned barcode data:12345 Resulting message string output: $12345
60
MagellanTM 1100i
Page 69
Global Prefix/Suffix
Global Prefix/Suffix, cont. START / END PROGRAMMING BARCODES Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to 7F. To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character(s). Reference the section, "Example: Setting a Prefix", for more information. Exit programming mode by scanning the “START/END” barcode again (scan “START/END” twice if less than 20 characters have been selected). DEFAULT SETTING PREFIX: 00 (None) DEFAULT SETTING SUFFIX: 0D (CR)
Set Prefix
Set Suffix
Product Reference Guide
61
Page 70
Data Editing
AIM ID AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list, as opposed to custom label ID characters you select yourself, and can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: •
A close brace character (ASCII ‘]’), followed by...
•
A code character (see the table below), followed by...
•
A modifier character (the modifier character is symbol dependent) SYMBOLOGY
CHA R
CHA R
SYMBOLOGY
UPC/EAN
E
Code 128/EAN 128
C
Code 39
A
MSI/Plessey
M
Codabar
F
RSS (GS1 Omnidirectional, GS1 Expanded)
e
Interleaved 2 of 5
I
Standard 2 of 5
S
Code 93
G
ISBN
Xa a. ISBN (X with a 0 modifier character)
Figure 4-3. AIM ID
Prefix
Label ID
AIM ID
Bar Code Data
Label ID
Suffix
START / END
PROGRAMMING BARCODES Disable AIM ID DEFAULT
Enable AIM ID
62
MagellanTM 1100i
Page 71
Label ID
Label ID A Label ID is used to identify a barcode (symbology) type. See Appendix D, Default Settings, for a listing for common symbologies. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types, see the previous feature, AIM ID. The Label ID is a customizable code of up to three ASCII characters (each of which are 007F) followed by a control character (00-01), This control character, when set to zero, does nothing. When set to one, it appends the symbology’s AIM ID to the Label ID.
NOTE
When the control character is set to 01 for UPC-A and UPC-E, it expands the label to EAN-13 and thus follows the EAN-13 Label ID settings.
To configure a Label ID: 1. Scan the START barcode. 2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate barcode. 3. Scan a barcode to select the symbology for which you wish to configure a custom Label ID. 4. Determine the desired character(s) (you may choose up to three) which will represent the Label ID for the selected symbology. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. 5. Turn to Appendix C, Alpha-Numeric Pad and scan the barcodes representing the hex characters determined in the previous step. For example, to make an equal sign (=), scan ‘3’ and ‘D’ followed by ‘0’ six times. Since this is a three-character buffer, ‘00’ is scanned for character two, ‘00’ for character three and ‘00’ for the control character. (‘00’ indicates no character.) 6. Scan the END barcode to exit programming mode. Figure 4-4. Label ID Position Options
Prefix
Label ID
Aim ID
Bar Code Data
Label ID
Suffix
OR
Product Reference Guide
63
Page 72
Data Editing
Label ID, cont. START / END
PROGRAMMING BARCODES
Label ID Transmission: Disable
Label ID Position: Before Barcode Data DEFAULT
Label ID Position: After Barcode Data
Set UPC-A Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex) Set UPC-A w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-E Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
64
MagellanTM 1100i
Page 73
Label ID
Label ID, cont. START / END
PROGRAMMING BARCODES
Set UPC-E w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set EAN-8 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-13 Label ID Character(s) ³ 0FOR 0 THIS 2 FEATURE: 7 DEFAULT SETTING F (46 hex)
Product Reference Guide
65
Page 74
Data Editing
Label ID, cont. START / END
PROGRAMMING BARCODES
Set EAN-13 w/P2 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P5 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex) Set EAN-13 w/C128 Addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set ISBN Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: I (49 hex)
Set IATA Label ID Character(s) ³ FOR 0 3THIS 4 FEATURE: C DEFAULT SETTING IA (4941 hex)
Set GTIN Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: G (47 hex)
Set GTIN w/P2 addon Label ID Character(s) ³ FOR 0 THIS6 FEATURE: 1 DEFAULT SETTING G2 (4732 hex)
Set GTIN w/P5 addon Label ID Character(s) ³ FOR 0 5THIS6 FEATURE: 2 DEFAULT SETTING G5 (4735 hex)
66
MagellanTM 1100i
Page 75
Label ID
Label ID, cont. START / END
PROGRAMMING BARCODES Set GTIN w/C128 addon Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex)
Set GS1 Omnidirectional Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex)
Set GS1 Expanded Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: RX (5258 hex) Set Code GS1 DataBar Limited Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: * (524C0000 hex) Set Code 39 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: * (2A hex)
Set Pharmacode 39 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set Code 128 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: # (23 hex)
Set I 2 of 5 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
Product Reference Guide
67
Page 76
Data Editing
Label ID, cont. START / END
PROGRAMMING BARCODES Set Codabar Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: % (25 hex) Set Code 93 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: & (26 hex)
Set Code 11 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set MSI/Plessey Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set Std 2 of 5 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: s (73 hex)
Set EAN UCC Composite Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: 0
Set PDF 417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: P (5000 hex)a
Set Datamatrix Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: Dm (446D hex) a. Default setting exceptions for PDF 417 Label ID are as follows: Default for RS-232 WN is ‘Q’ (0x5100). Default for USB-HIDPOS is ‘P ‘ (0x5020), or ‘P-Space’.
68
MagellanTM 1100i
Page 77
Label ID
Label ID, cont.
NOTE
For the 2D symbologies on this page, the Label ID is 4 bytes. The first 3 bytes are characters for the label ID. A 00 (hex) value in the first 3 bytes indicates the end of the label ID characters. The 4th byte is a control byte. The use of the control byte is as follows: bit 0-if set to 1, the AIM Id is appended for that label type
START / END
PROGRAMMING BARCODES
Set Micro PDF 417 Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: mP (6D500000 hex) Set QR Code Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: QR (51520000 hex)
Set Maxicode Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: MC (4D430000 hex)
Set Aztec Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: Az (417A0000 hex) Set GS1 DataBar Omnidirectional 2D Composite Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: R4 (52340000 hex) Set GS1 DataBar Limited 2D Composite Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: RL (524C0000 hex) Set GS1 DataBar Expanded 2D Composite Label ID Character(s) DEFAULT SETTING FOR THIS FEATURE: RX (52340000 hex)
Product Reference Guide
69
Page 78
Data Editing
Case Conversion This feature can convert scanned barcode data to either all lower case (a through z) or all upper case (A through Z) characters. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE
START / END
PROGRAMMING BARCODES Disable DEFAULT
Convert to Upper Case
Convert to Lower Case
70
MagellanTM 1100i
Page 79
Character Conversion
Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF. With the label, AG15TA81, it would look as follows after the character conversion: BG25TB82. The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Scan the START/END barcode. 2. Scan the Character Conversion barcode. 3. Determine the desired string. Up to sixteen positions can be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string. The positions not used must be filled with the character ‘F’. NOTE
4. Turn to Appendix C, Alpha-Numeric Pad and scan the barcodes representing the hex characters determined in the previous step. When the last character is scanned, the scanner will sound a triple beep. 5. Scan the START/END barcode to exit Programming Mode.
START / END
PROGRAMMING BARCODES
Character Conversion DEFAULT SETTING FOR THIS FEATURE: FFFFFFFFFFFFFFFF hex (no conversion)
Product Reference Guide
71
Page 80
Data Editing
NOTES
72
MagellanTM 1100i