Page 81
Chapter 5
Symbologies The scanner supports the following symbologies (barcode types). Options for each symbology are included in this chapter. • UPC-A
• Code 32 Italian Pharmacode
• UPC-E
• Code 128
• EAN-13
• Interleaved 2 of 5
• EAN-8
• Codabar
• GS1 DataBar Omnidirectional / Stacked Omnidirectional
• Code 93
• GS1 DataBar Expanded / Expanded Stacked
• MSI/Plessey
• GS1 DataBar Limited
• Standard 2 of 5
• Code 39
Factory Defaults - for the standard RS-232 interface are indicated in bold text throughout this section. Reference Appendix D, Default Settings for default exceptions for your interface.
UPC-A Disable/Enable UPC-A When disabled, the scanner will not read UPC-A barcodes. START / END PROGRAMMING BARCODES
Disable UPC-A
Enable UPC-A DEFAULT
Product Reference Guide
73
Page 82
Symbologies
UPC-A, continued Check Digit Transmission Enable this option to transmit the check digit along with UPC-A barcode data. START / END PROGRAMMING BARCODES
Don’t Send Check Digit
Send Check Digit DEFAULT
Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING BARCODES Don’t Expand to EAN-13 DEFAULT
Expand to EAN-13
74
MagellanTM 1100i
Page 83
UPC-A
UPC-A, continued Number System Transmission This feature enables/disables transmission of UPC-A System Number. START / END PROGRAMMING BARCODES
Disable Number System Transmission
Enable Number System Transmission DEFAULT
UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
75
Page 84
Symbologies
UPC-A, continued UPC-A In-store Minimum Reads This feature specifies the minimum number of consecutive times an in-store printed label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
76
MagellanTM 1100i
Page 85
UPC-E
UPC-E The following options apply to the UPC-E symbology.
Disable/Enable UPC-E When disabled, the scanner will not read UPC-E barcodes. START / END PROGRAMMING BARCODES
Disable UPC-E
Enable UPC-E DEFAULT
Check Digit Transmission Enable this option to transmit the check digit along with UPC-E barcode data. START / END PROGRAMMING BARCODES
Don’t Send Check Digit
Send Check Digit DEFAULT
Product Reference Guide
77
Page 86
Symbologies
UPC-E, continued Number System Digit The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned barcode data. START / END PROGRAMMING BARCODES Exclude Number System Digit DEFAULT
Include Number System Digit ³
0 2
8 0 1
Expand to UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A. Selecting this feature also changes the symbology ID to match those required for UPC-A. START / END PROGRAMMING BARCODES Don’t Expand UPC-E to UPC-A DEFAULT
Expand UPC-E to UPC-A
78
MagellanTM 1100i
Page 87
UPC-E
UPC-E, continued Expand UPC-E to EAN13 Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING BARCODES Don’t Expand UPC-E to EAN-13 DEFAULT
Expand UPC-E to EAN-13
Minimum Reads This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES
Minimum = 1 Read
Minimum = 2 Reads DEFAULT
Minimum = 3 Reads
Minimum = 4 Reads ³
Product Reference Guide
0 0 6 2 0
79
Page 88
Symbologies
GTIN The following options apply to the GTIN label data format.
Expand UPC/EAN to GTIN When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format. START / END PROGRAMMING BARCODES Don’t Expand to GTIN DEFAULT
Expand to GTIN
80
MagellanTM 1100i
Page 89
EAN-13
EAN-13 The following options apply to the EAN-13 symbology.
Disable/Enable EAN-13 When disabled, the scanner will not read EAN-13 barcodes. START / END PROGRAMMING BARCODES
Disable EAN-13
Enable EAN-13 DEFAULT
Check Digit Transmission Enable this option to transmit the check digit along with EAN-13 barcode data. START / END PROGRAMMING BARCODES
Don’t Send Check Digit
Send Check Digit DEFAULT
Product Reference Guide
81
Page 90
Symbologies
EAN-13, continued EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. START / END PROGRAMMING BARCODES Don’t Transmit EAN-13 Flag 1 Char
Transmit EAN-13 Flag 1 Char DEFAULT
ISBN When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number) and appends an ISBN check character to the end of the label. These codes are used for books and magazines. Labels with ISBN codes start with "978". Example:
Barcode data:
“9789572222720”
Output:
“9572222724”
START / END PROGRAMMING BARCODES Disable ISBN DEFAULT
Enable ISBN