The text of a manual · part 15 of 26
Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 121 to 130
Pages 121 to 130 of 208, from Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1100i
Page 121
Code 32 Italian Pharmacode
Code 32 Italian Pharmacode, continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BARCODES
Disable Check Char Transmission
Enable Check Char Transmission DEFAULT
Product Reference Guide
113
Page 122
Symbologies
Code 128 The following options apply to the Code 128 symbology.
Disable/Enable Code 128 When this feature is disabled, the scanner will not read Code 128 barcodes. START / END PROGRAMMING BARCODES Disable Code 128
Enable Code 128 DEFAULT
Disable/Enable EAN 128 When this feature is disabled, the scanner will not read EAN 128 barcodes. START / END PROGRAMMING BARCODES Disable EAN 128
Enable EAN 128 DEFAULT
114
MagellanTM 1100i
Page 123
Code 128
Code 128, continued Transmit Function Characters Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. Function codes are transmitted as follows: •
FNC1 = 80 hex
•
FNC2 = 81 hex
•
FNC3 = 82 hex
•
FNC4 = 83 hex
START / END PROGRAMMING BARCODES Don’t Transmit Function Characters DEFAULT
Transmit Function Characters
Product Reference Guide
115
Page 124
Symbologies
Code 128, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Code 128 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Code 128 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Code 128 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Code 128 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT
Fixed Length Decoding
116
MagellanTM 1100i
Page 125
Code 128
Code 128, continued Code 128 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation. For Code 128 barcodes, only the data characters are included in the length calculations. NOTE
4. Scan the END barcode. START / END PROGRAMMING BARCODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 01
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 80
Code 128 Conversion to Code 39 Enables/disables expansion of Code 128 labels to Code 39. START / END PROGRAMMING BARCODES Disable DEFAULT
Enable
Product Reference Guide
117
Page 126
Symbologies
Code 128, continued Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. START / END PROGRAMMING BARCODES
Disable Code 128 Stitching
Enable Code 128 Stitching DEFAULT
Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
118
MagellanTM 1100i
Page 127
Interleaved 2 of 5
Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.
Disable/Enable Interleaved 2 of 5 When this feature is disabled, the scanner will not read Interleaved 2 of 5 barcodes. START / END PROGRAMMING BARCODES Disable Interleaved 2 of 5 DEFAULT
Enable Interleaved 2 of 5
Check Digit Calculation When enabled, the scanner will calculate the check digit of the labels. START / END PROGRAMMING BARCODES Disable Check Digit Calculation DEFAULT
Enable Check Digit Calculation
Product Reference Guide
119
Page 128
Symbologies
Interleaved 2 of 5, continued Check Digit Transmit Enable this option to transmit the check digit with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Digit Transmission DEFAULT
Enable Check Digit Transmission
120
MagellanTM 1100i
Page 129
Interleaved 2 of 5
Interleaved 2 of 5, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT
Fixed Length Decoding
Product Reference Guide
121
Page 130
Symbologies
Interleaved 2 of 5, continued Interleaved 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation.
NOTE
For Interleaved 2 of 5 barcodes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.
4. Scan the END barcode. START / END PROGRAMMING BARCODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 06
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50
122
MagellanTM 1100i