Page 131
Interleaved 2 of 5
Interleaved 2 of 5, continued Interleaved 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an Interleaved 2 of 5 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. Only functions when Fixed Length Decoding is enabled. NOTE
START / END PROGRAMMING BARCODES Disable Interleaved 2 of 5 Stitching DEFAULT
Enable Interleaved 2 of 5 Stitching
Product Reference Guide
123
Page 132
Symbologies
Interleaved 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
124
MagellanTM 1100i
Page 133
Codabar
Codabar The following options apply to the Codabar symbology.
Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar barcodes. START / END PROGRAMMING BARCODES Disable Codabar DEFAULT
Enable Codabar
Check Character Verification When enabled, the scanner will verify the check character of the labels. START / END PROGRAMMING BARCODES Disable Check Char Verification DEFAULT
Enable Check Char Verification
Product Reference Guide
125
Page 134
Symbologies
Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Char Transmission
Enable Check Char Transmission DEFAULT
126
MagellanTM 1100i
Page 135
Codabar
Codabar, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Codabar Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Codabar Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT
Fixed Length Decoding
Product Reference Guide
127
Page 136
Symbologies
Codabar, continued Codabar Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation. For Codabar barcodes, all start, stop, check and data characters are included in the length calculations. NOTE
4. Scan the END barcode. START / END PROGRAMMING BARCODES Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 03
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50
Quiet Zones This feature enable/disables the requirement that quiet zones must be present for Codabar barcodes. START / END PROGRAMMING BARCODES Don’t require Quiet Zones DEFAULT
Require Quiet Zones
128
MagellanTM 1100i
Page 137
Codabar
Codabar, continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application. START / END PROGRAMMING BARCODES
Start/Stop Type: ABCD/TN*E
Start/Stop Type: ABCD/ABCD
Start/Stop Type: abcd/tn*e
Start/Stop Type: abcd/abcd DEFAULT
Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below. START / END PROGRAMMING BARCODES
Disable Start/Stop Char Transmission
Enable Start/Stop Char Transmission DEFAULT
Product Reference Guide
129
Page 138
Symbologies
Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match. START / END PROGRAMMING BARCODES Disable Start/Stop Char Match DEFAULT
Enable Start/Stop Char Match
Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. Only functions when Fixed Length Decoding is enabled. NOTE
START / END PROGRAMMING BARCODES Disable Codabar Stitching DEFAULT
Enable Codabar Stitching
130
MagellanTM 1100i
Page 139
Codabar
Codabar, continued Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
131
Page 140
Symbologies
Code 93 The following options apply to the Code 93 symbology.
Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 barcodes. START / END PROGRAMMING BARCODES Disable Code 93 DEFAULT
Enable Code 93
132
MagellanTM 1100i