For the Datalogic 1100i

Page 131

Interleaved 2 of 5

Interleaved 2 of 5, continued Interleaved 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an Interleaved 2 of 5 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BARCODES Disable Interleaved 2 of 5 Stitching DEFAULT

Enable Interleaved 2 of 5 Stitching

Product Reference Guide

123

Page 132

Symbologies

Interleaved 2 of 5, continued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

124

MagellanTM 1100i

Page 133

Codabar

Codabar The following options apply to the Codabar symbology.

Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar barcodes. START / END PROGRAMMING BARCODES Disable Codabar DEFAULT

Enable Codabar

Check Character Verification When enabled, the scanner will verify the check character of the labels. START / END PROGRAMMING BARCODES Disable Check Char Verification DEFAULT

Enable Check Char Verification

Product Reference Guide

125

Page 134

Symbologies

Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Char Transmission

Enable Check Char Transmission DEFAULT

126

MagellanTM 1100i

Page 135

Codabar

Codabar, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first fixed length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Codabar Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the END barcode. 4. Set Length 1 to the first variable length by following the Codabar Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Codabar Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

127

Page 136

Symbologies

Codabar, continued Codabar Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation. For Codabar barcodes, all start, stop, check and data characters are included in the length calculations. NOTE

4. Scan the END barcode. START / END PROGRAMMING BARCODES Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 03

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50

Quiet Zones This feature enable/disables the requirement that quiet zones must be present for Codabar barcodes. START / END PROGRAMMING BARCODES Don’t require Quiet Zones DEFAULT

Require Quiet Zones

128

MagellanTM 1100i

Page 137

Codabar

Codabar, continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application. START / END PROGRAMMING BARCODES

Start/Stop Type: ABCD/TN*E

Start/Stop Type: ABCD/ABCD

Start/Stop Type: abcd/tn*e

Start/Stop Type: abcd/abcd DEFAULT

Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below. START / END PROGRAMMING BARCODES

Disable Start/Stop Char Transmission

Enable Start/Stop Char Transmission DEFAULT

Product Reference Guide

129

Page 138

Symbologies

Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match. START / END PROGRAMMING BARCODES Disable Start/Stop Char Match DEFAULT

Enable Start/Stop Char Match

Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. Only functions when Fixed Length Decoding is enabled. NOTE

START / END PROGRAMMING BARCODES Disable Codabar Stitching DEFAULT

Enable Codabar Stitching

130

MagellanTM 1100i

Page 139

Codabar

Codabar, continued Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

131

Page 140

Symbologies

Code 93 The following options apply to the Code 93 symbology.

Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 barcodes. START / END PROGRAMMING BARCODES Disable Code 93 DEFAULT

Enable Code 93

132

MagellanTM 1100i