The text of a manual · part 14 of 26
Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 111 to 120
Pages 111 to 120 of 208, from Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1100i
Page 111
GS1 DataBar Expanded / Expanded Stacked
GS1 DataBar Expanded / Expanded Stacked, continued Coupon Read Control This feature controls coupon reading. START / END PROGRAMMING BARCODES
Disable coupon filtering
Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding DEFAULT
Enable GS1 DataBar coupon decoding Disable UPCA coupon decoding
Product Reference Guide
103
Page 112
Symbologies
GS1 DataBar Limited The following options apply to the GS1 DataBar Limited symbology.
Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited barcodes. START / END PROGRAMMING BARCODES Disable GS1 DataBar Limited DEFAULT
Enable GS1 DataBar Limited
GS1-128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label data format. START / END PROGRAMMING BARCODES Disable GS1-128 Emulation DEFAULT
Enable GS1-128 Emulation
104
MagellanTM 1100i
Page 113
GS1 DataBar Limited
GS1 DataBar Limited, continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
105
Page 114
Symbologies
Code 39 The following options apply to the Code 39 symbology.
Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 barcodes. START / END PROGRAMMING BARCODES
Disable Code 39
Enable Code 39 DEFAULT
Check Character Calculation When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code 39 labels. START / END PROGRAMMING BARCODES Disable Check Char Calculation DEFAULT
Enable Check Char Calculation
106
MagellanTM 1100i
Page 115
Code 39
Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Char Transmission
Enable Check Char Transmission DEFAULT
Start/Stop Characters Enables/disables transmission of Code39 start and stop characters. START / END PROGRAMMING BARCODES Don’t Transmit Start/Stop Characters DEFAULT
Transmit Start/Stop Characters
Product Reference Guide
107
Page 116
Symbologies
Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. START / END PROGRAMMING BARCODES Disable Code 39 Full ASCII DEFAULT
Enable Code 39 Full ASCII
108
MagellanTM 1100i
Page 117
Code 39
Code 39, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Code 39 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT
Fixed Length Decoding
Product Reference Guide
109
Page 118
Symbologies
Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation.
NOTE
For Code 39 barcodes, all check, data and full ASCII shift characters are included in the length calculations. Start/Stop characters are not included.
4. Scan the START/END barcode. START / END PROGRAMMING BARCODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 02
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50
Quiet Zones This feature enables/disables the requirement that quiet zones must be present for Code 39 barcodes. START / END PROGRAMMING BARCODES Don’t require Quiet Zones DEFAULT
Require Quiet Zones
110
MagellanTM 1100i
Page 119
Code 39
Code 39, continued Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. START / END PROGRAMMING BARCODES
Disable Code 39 Stitching
Enable Code 39 Stitching DEFAULT
Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
111
Page 120
Symbologies
Code 32 Italian Pharmacode The following options apply to the Code 32 Italian Pharmacode symbology.
Disable/Enable Code 32 Italian Pharmacode When this feature is disabled, the scanner will not read Code 32 Italian Pharmacode barcodes. START / END PROGRAMMING BARCODES Disable Code 32 Italian Pharmacode DEFAULT
Enable Code 32 Italian Pharmacode
Start/Stop Characters Enables or disables transmission of Code 32 Italian Pharmacode start/stop characters. START / END PROGRAMMING BARCODES Don’t Transmit Start/Stop Characters DEFAULT
Transmit Start/Stop Characters ³
112
0
0
6
0
1
MagellanTM 1100i