Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 26

Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 111 to 120

Pages 111 to 120 of 208, from Magellan 1100i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 1100i

Page 111

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked, continued Coupon Read Control This feature controls coupon reading. START / END PROGRAMMING BARCODES

Disable coupon filtering

Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding DEFAULT

Enable GS1 DataBar coupon decoding Disable UPCA coupon decoding

Product Reference Guide

103

Page 112

Symbologies

GS1 DataBar Limited The following options apply to the GS1 DataBar Limited symbology.

Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited barcodes. START / END PROGRAMMING BARCODES Disable GS1 DataBar Limited DEFAULT

Enable GS1 DataBar Limited

GS1-128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label data format. START / END PROGRAMMING BARCODES Disable GS1-128 Emulation DEFAULT

Enable GS1-128 Emulation

104

MagellanTM 1100i

Page 113

GS1 DataBar Limited

GS1 DataBar Limited, continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

105

Page 114

Symbologies

Code 39 The following options apply to the Code 39 symbology.

Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 barcodes. START / END PROGRAMMING BARCODES

Disable Code 39

Enable Code 39 DEFAULT

Check Character Calculation When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code 39 labels. START / END PROGRAMMING BARCODES Disable Check Char Calculation DEFAULT

Enable Check Char Calculation

106

MagellanTM 1100i

Page 115

Code 39

Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Char Transmission

Enable Check Char Transmission DEFAULT

Start/Stop Characters Enables/disables transmission of Code39 start and stop characters. START / END PROGRAMMING BARCODES Don’t Transmit Start/Stop Characters DEFAULT

Transmit Start/Stop Characters

Product Reference Guide

107

Page 116

Symbologies

Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. START / END PROGRAMMING BARCODES Disable Code 39 Full ASCII DEFAULT

Enable Code 39 Full ASCII

108

MagellanTM 1100i

Page 117

Code 39

Code 39, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Code 39 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BARCODES Variable Length Decoding DEFAULT

Fixed Length Decoding

Product Reference Guide

109

Page 118

Symbologies

Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing the length in decimal notation.

NOTE

For Code 39 barcodes, all check, data and full ASCII shift characters are included in the length calculations. Start/Stop characters are not included.

4. Scan the START/END barcode. START / END PROGRAMMING BARCODES

Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 02

Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 50

Quiet Zones This feature enables/disables the requirement that quiet zones must be present for Code 39 barcodes. START / END PROGRAMMING BARCODES Don’t require Quiet Zones DEFAULT

Require Quiet Zones

110

MagellanTM 1100i

Page 119

Code 39

Code 39, continued Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data will be decoded if all barcode proofing requirements are met. START / END PROGRAMMING BARCODES

Disable Code 39 Stitching

Enable Code 39 Stitching DEFAULT

Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

111

Page 120

Symbologies

Code 32 Italian Pharmacode The following options apply to the Code 32 Italian Pharmacode symbology.

Disable/Enable Code 32 Italian Pharmacode When this feature is disabled, the scanner will not read Code 32 Italian Pharmacode barcodes. START / END PROGRAMMING BARCODES Disable Code 32 Italian Pharmacode DEFAULT

Enable Code 32 Italian Pharmacode

Start/Stop Characters Enables or disables transmission of Code 32 Italian Pharmacode start/stop characters. START / END PROGRAMMING BARCODES Don’t Transmit Start/Stop Characters DEFAULT

Transmit Start/Stop Characters ³

112

0

0

6

0

1

MagellanTM 1100i