Page 31

23 It will re-appear from time to time about every four (4) minutes to remind you to charge the unit.

Main Battery Expired The Main Battery Expired appears when the power is really too low to power the unit anymore. It is then better to shutdown your device immediately by tapping Shutdown. Otherwise the device will turn off by itself after 30 seconds.

FIGURE 12 If the user persists to use the unit after this message appears, it is possible that the unit does not turn-off properly and reboot when you will start to charge it. Upon reactivation, a message indicating that the system has been improperly RESET by a LOWBAT may appear on the screen.

Low battery messages on Backup Battery The CE5000 backup battery allows you to keep programs, files and data in the memory for hours. In practice, the backup battery is used only while you replace the main battery, when the main battery is absent or when the main battery power is expired. K CE.NET Version Programs and files are stored into the Storage Flash. The Storage Flash requires no battery to maintain the information. So, under CE.NET only information that is not yet stored in a file can be lost when the backup battery runs down. K CE 3.0 Version Programs and files are stored into the DRAM memory. The DRAM memory requires a battery to maintain the information. So, under CE 3.0 all information will be lost when the backup Battery runs down. Even if the main battery is too low to power the CE5000 unit, enough energy remains to power the memory for a period of about 30 to 50 hours without using the backup battery. The backup battery will be turned on to maintain the memory only when the main battery is completely dead. The backup battery is recharged every time you recharge the unit. The backup battery is also recharged from the main battery even if the unit is not charging.

MAN39-A (CMU035-A7)

Page 32

24 The life duration of the backup battery alone is about 12 hours at room temperature. The backup battery capacity decreases greatly at temperatures below 0°C When the Backup Battery Low message appears the data is still secure but the backup battery needs to be recharged.

FIGURE 13 When the Backup Battery Very Low message appears the backup battery is so low that data and programs could have been corrupted.

FIGURE 14

Replacing the main battery It is preferable to replace the main battery in a clean and dry area. IMPORTANT ALWAYS TURN-OFF THE UNIT BEFORE REMOVING THE BATTERY. ALWAYS CONSIDER THE INFLUENCE ON THE CALIBRATION SETTINGS •

On a regular CE5000, remove the battery for at least 2-5 minutes to clear the calibration settings. Proceed or not to a Power Gauge Calibration

•

On a CE5000X the calibration settings cannot be cleared. When the battery is replaced you must proceed to a Power Gauge Calibration or to manually set the approximate power remaining in the installed battery

The CE5000 unit uses a specifically designed and tested main battery to insure quick charging time, long-battery life and to withstand shocks and vibrations. To be sure that the battery is conform for usage on a DAP equipment, buy them directly from DAP TECHNOLOGIES or one of its distributors and check for the DAP label on it. Part number: DC800

MAN35-A (CMU035-A7)

Page 33

25 Replacement of the main battery is an easy task. Follow the steps outlined below.

Battery cover CHECK FOR THE ARROW

Foam: Battery protector

Simply insert the battery this side first

·

Turn off the unit first (see section “Turning the Unit OFF Manually”)

·

Using a small flat blade screwdriver, remove the four (4) screws marked “Release screws for battery compartment” in Figure 3.

·

Pull out the battery and insert the new one inserting the left side first. Be sure to align the arrow on the battery toward the right as shown on figure. The foam should go over the battery for a tight fit in the casing.

·

Re-install the four (4) screws and tighten them until you feel some resistance.

·

Turn the unit back on and charge the battery if required.

BATTERY PRECAUTIONS WARNING: Personal injuries may result if batteries are not handheld with care •

If the battery becomes unusable, dispose of it immediately.

•

Keep the battery away from heat sources, including open fires and direct sunlight.

•

Never disassemble a battery.

•

Do not place the battery through metal pieces that can short-circuit the power contact pins.

Recycling the battery The type of main battery used in all CE5000 units is not considered as a hazardous waste. Refer to your local regulation for the proper methods of disposal.

MAN39-A (CMU035-A7)

Page 34

26

Power Gauge Calibration The CE5000 includes a Power Gauge to monitor the power remaining in the main battery at any time (Good, Low, Very Low). This gauge indicates the estimated remaining time and percentage. When the power gauge is calibrated, the Battery Status indicator will flash when the battery reaches the Battery Warning Level. To be operational, the Power Gauge needs to be calibrated. This could take up to 20 hours. NOTE A non-calibrated power gauge DOES NOT affects neither the battery life nor the charging duration. The calibration only allows the CE5000 to accurately report the remaining capacity of the main battery and to enable the Battery Status indicator to blink when the battery reaches the Warning Level. •

A regular CE5000 can be used with a non-calibrated power gauge.

•

On a CE5000X the power gauge is always calibrated but accuracy decrease with the time.

You can start the application by pressing CTRL and F2

Tap on the File menu and select Start Calibration

Result of the calibration will be given at the end of the cycle. NOTE On a CE5000X, calibration will always stay valid but if the delay between two calibrations is to long, displayed information will be less accurate. On a regular CE5000, calibration will stay valid • as long as the main battery is not removed for more than 2 minutes • as long as the main battery is not deeply discharged • for about 30 charge cycle Results highly depends of the installed options and of the power save settings. Discharge duration will be much lower with color screen compared to a monochrome screen.

MAN35-A (CMU035-A7)

Page 35

27 Always compare the current reading to previous readings to know the current battery capacity and the tendency. Click on File > View Log File to get the historic of the BATMNGR results.

NOTE To clear the log file, delete the file BATMNGR.TXT under the folder My Computer. If values are far from the most recent values it is suggested to: • Run another BATMNGR and compare the numbers. •

Check if the power save settings have not changed (power off delay, screen and backlit delay).

If it still remains with values far from the previous values: • Replace the battery, •

Call DAP Technologies Customer Support.

NOTE The displayed capacity will be always lower than the capacity written on the battery (for example 2200 mAh displayed, 2400 mAh printed on the battery). This is caused by the fact that a small part of the main battery is reserved to extend the backup battery duration.

Quick calibration (CE5000X only) Since the CE5000X calibration cannot be cleared and because you not always have time to proceed to a full calibration when you replace the battery in the field, it is possible to set the approximate current setting of the new battery.

When the new battery is installed, press Ctrl F4 to display the Battery Level Properties menu, or click Start, Control Panel, and _Battery Level.

MAN39-A (CMU035-A7)

Page 36

28 Click on the button that shows the current power remaining in the new battery. If you replace the discharged battery by a new freshly recharged battery, the value to set will be 100%. If you prefer that the battery, whatever its condition, always reports as being 100% charged click the box marked I don’t want to use…. In that case, the system looks like having a non-calibrated battery. The message Battery Low Level will not be displayed and the Battery Status Indicator will never flash.

MAN35-A (CMU035-A7)

Page 37

29

USE OF THE KEYBOARD Multi-key entry Sometimes you might need to press more than one key to get a character or a special function. The SHIFT (é), CTL, ALT or blue key are the keys that can precede a letter or a digit to modify its original value. According to your preferences or as the situation demands, you can decide to use one of the two following methods to form the sequence of keys: •

Press the keys one after the other, releasing the previous key before pressing the next. This method (also known as one finger typing) allows you to use only one finger to make any function.

•

You can press the two (2) keys together, using two fingers.

Or The color code simplifies the way the keyboard works. The blue key needs to be pressed first to get a character in blue. A simple way to understand how the multi-key entry works is by typing a ?. The ? Being in blue means that you must precede it with the blue key which is also in blue. You may use either method described above.

Auto-repeat A key will automatically start to repeat if left pressed for more than one second. It will stop repeating once released.

Digit and letter keys To generate a character either as an alpha (letter) or numeric (digit) value, simply press the key corresponding to the desired letter or digit. Letters are normally all in lower case.

Lower case/ Upper case once To generate an upper case letter, press the following keys: the SHIFT (é) followed by the desired letter.

Lower case/ Upper case continuous To generate a of upper case letters, first press the blue key then the 0 (zero) also marked Caps in blue. This will simulate the Caps Lock key you find on a conventional PC keyboard.

Punctuation and special symbols To enter punctuation marks or special typographic symbols, press the blue key and then the letter key marked with the desired symbol in blue. To generate a ?, press the blue key and then V.

Function keys (F1…F4) The function keys are for direct access to a specific function in your application. Function keys F1 to F4 are direct access. Other functions might be attached to keys SHIFT (é) F1 to F4 and CTL F1 to F4. Please refer to your Application User’s Guide to know the intended meaning of these keys.

MAN39-A (CMU035-A7)

Page 38

30 Some functions keys are already used by the Operating System. Refer to TABLE 1 in section “Other Special Keys” and to TABLE 2 in section “ADVANCED USER’S INFORMATION , Active Sync Communication” NOTE On the CE5000LS, the F3 <SCAN> key is generally used to start a barcode scan and, consequently, will not generate a F3 function key. See the Security Notice (FIGURE 4).

Activating the backlighted screen and keyboard To use the unit in a low-light environment, every CE5000 is equipped with a backlighted screen. Optionally, the CE5000 can also be equipped with a backlighted keyboard. NOTE Backlighting can drain batteries rapidly if used constantly. Only use it when necessary in a low-light environment. To activate the backlighting of the screen and keyboard, press the blue key and then the F3 key. The same sequence will deactivate this feature. Backlighting normally turns off by itself after 45 seconds if there is no key pressed or new information on the screen.

Additional Adjustment on the Display Background and Contrast NOTE These keys have only a small effect on a CE5000X with color screen

The CE5000 includes a precise automatic temperature compensation system to assure you that the screen display contrast will be at its best in any circumstance. In extreme temperatures outside of the -20 to +50°C (-4 to +122°F) range, or simply to adjust it to your preference, you may have to manually readjust it. In extreme low temperatures, pressing the blue key and then the TAB key one after the other can increase the display contrast. You can hold down the TAB key to take advantage of the keyboard repeat function and go quickly from one step to another. In extreme high temperatures, pressing the blue key and then the F4 key one after the other can reduce the display background darkness. You can hold down the F4 key to take advantage of the keyboard repeat function and go quickly from one step to another.

Other Special Keys The tab key computer.

. is used in the same way as the one found on a desktop

Other popular special keys are shift 0 to shift 9 (é0 to é9), and é. They respectively give these characters: ) ! @ # $ % ^ & * et (

MAN35-A (CMU035-A7)

Page 39

31 The CE5000 also have pre-defined functions keys F1 SHIFT + F1 CTRL + F1 CTRL + F3

Pre-programmed for communication. See section ActiveSync communication

F2

K CE.NET Version (CE5000X) Display the <Power> menu to get the current power level.

CTL + F2

Starts the BATMNGR program to re-calibrate the power gauge.

SHIFT (é) + F2

K CE.NET Version (CE5000X) Start the <Screen Calibration> menu.

CTL+ Blue key + F2

K CE 3.0 Version (CE5000) Activated/de-activated the taskbar

CTRL + F4

K CE.NET Version (CE5000X) Start the <Battery level> menu to set-up a non-calibrated battery. See section Quick Calibration

ALT-ESC

K CE 3.0 Version (CE5000) Show the Task Manager

ALT-TAB

K CE.NET Version (CE5000X) Show the Task Manager K CE 3.0 Version (CE5000) Toggle between running task

TABLE 1 All these pre-defined functions keys are available at the initial configuration of the CE5000 unit. They could have been disabled or associated with other programs by your application software. ADVANCED USERS Refer to “DAP Shell” section on DAP Technologies Technical Web Site for complete information about viewing or changing these functions keys. For information how to log-in see section “ADVANCED USER INFORMATION” in that guide.

MAN39-A (CMU035-A7)

Page 40

32

MAN35-A (CMU035-A7)