Page 21

13

Communication Cradle Cradles are available for office and vehicle use. The installation requires a modular charger available from DAP Technologies: For office use: • CS810 (110Vac) • CS820 (220Vac) For vehicle use (12 Vdc adapter): • • CS810 / CS820

CS512 with a 240 cm (95”) power cable. CS512SCH with a 15 cm (6") power cable IMPORTANT

The Vehicle Cradles require a power source of 12 to 18 Vdc. The cigarette lighter adapter should be clean and free of corrosion to offer no electrical resistance Before charging the CE5000, you first need to power the communication cradle. Insert the round connector of the modular charger into the round connector at the top left of the cradle. Connect the modular charger to the wall outlet. From there, to recharge the CE5000 battery you just need to slide the CE5000 into the cradle, bottom first.

CS512 / CS512SCH

The CE5000’s Battery Status Indicator (Figure 3) will turn red in the next five (5) seconds indicating that charging is in progress and will become green when the full charge is completed. This could take up to five (5) hours. The led could turn on immediately green if the unit is fully charge. If the unit was turned off, it should turn back on after a few seconds or at the most after 2 or 3 minutes when the main battery was maintained very low for a while. Processing will resume exactly where it was interrupted once recharging starts.

MAN39-A (CMU035-A7)

Page 22

14

External Battery charger

Charge Indicators

It is also possible to charge the main battery using the External Battery Charger. Simply remove the main battery from the CE5000 and insert it into the External Battery Charger. See section “Replacing the main Battery” if you need help. Be sure to power the charger using the appropriate AC/DC adapter. The Charge Indicator will light-up red to indicate that it is charging the battery. It will turn green after up to 5 hours. A normal full charge takes about 4 hours. If ever the Charge Indicator does not turn red when inserting the battery, this means that the battery is already over 90% charged, assuming that the power cable is well connected. If ever the Charge Indicator flashes a problem has occurred during the recharge. Or it could also be that the battery temperature is of range (10°C to 45°C // 50°F to 112°F). Remove the battery from the charger, disconnect the charger for 5 to 10 seconds to remove the error status and retry a new charge.

Automatic Shutoff You generally do not have to worry about turning off the CE5000 unit to save the battery. If the unit remains inactive for more than three minutes, it will turn off automatically. The unit will save the exact status of your application program and data before turning off. The CE5000 unit is turned off when the display is empty and the keyboard does not beep when a key is pressed. To restart, use the normal start-up procedure. Once restarted, you can resume your task where you left off. When turned off with fully recharged batteries, you can store the CE5000 unit for several days without needing to recharge them. Refer to section “MAINTENANCE AND STORAGE” for more information about storing the unit.

Turning The Unit ON Out of the charger, the unit will normally turns off by itself after about three (3) minutes. ON/OFF

To turn ON the CE5000 unit, simply press the F1 key on the keyboard. The CE5000 screen will normally activate. It could occur that the battery is too low to start the unit when pressing the F1 key. In that case refer to section BATTERY AND CHARGING for changing instructions.

MAN35-A (CMU035-A7)

Page 23

15

Turning The Unit OFF Manually

ON/OFF

To turn off the CE5000 unit press the following keys: blue key and F1 one after the other (releasing the previous key before pressing the next). The display will clear and the keyboard will no longer beep when a key is pressed. To restart, use the normal start-up procedure. NOTE The device will not turn off when charging.

Battery Status Indicator While charging, the Battery Status Indicator has several meanings. COLOR

MEANING

Red, continuous

Charger connected, unit is charging

Green, continuous

Charger connected, unit fully charged

Red, blinking

User’s defined low battery warning

Yellow, continuous

Charger detected but the battery temperature is too high or low to be recharged. Charging will start when temperature will be adequate.

Yellow, blinking

Charging disabled by the application program (as with BATMNGR)

Turned off

Power from the charger not detected

MAN39-A (CMU035-A7)

Page 24

16

Touch Screen Calibration NOTE At any time you can press CTRL + ALT + Blue Key + S to display the touch calibration menu.

You might have to calibrate the touch screen when you receive a new unit or after you have stored the unit for a long period of time without recharging. Calibration is simply done by touching the center of the cross a couple of seconds. When the cross moves to another place repeat the operation.

Hold your pen until the cross moves.

K CE.NET Version (CE5000X) The function can also be reached by just to typing Shift and F2. Alternatively you can click Start / Settings / Control Panel / Stylus. K CE 3.0 Version The function can also be reached under Control Panel and Stylus.

Use of the Touch Screen The touch screen is very user friendly. You simply have to use the special Stylus/Pen provided by DAP Technologies.

To move a file to a folder, touch the file with your pen and drag it into the folder.

Double-tap on the folder to open it.

Double-tap on the program to run it.

MAN35-A (CMU035-A7)

Page 25

17

TO SEE MORE OBJECTS Move the navigation bar by sliding your Stylus/Pen on the Navigation Bar or Click the Navigation Arrow

CE 5000X ONLY

Start Button Click to display additionnnal running programs

MAN39-A (CMU035-A7)

Page 26

18

Caring of the Touch Screen With minimal maintenance and if you avoid using abrasive or metallic pointer on the touch screen it should last for many years. Use a normal soft cloth and mild soap to clean the touch screen of the CE5000 unit. Do not use abrasives as they may damage the finish. IMPORTANT Do not use any other Stylus/Pen than the one provided by DAP Technologies. If not, it may damage your touch screen. Replace or clean the stylus as soon as it seems damaged or dirty IMPORTANT Apply a normal pressure on the touch screen. An abusive pressure might damage its performance.

Loading files and programs Your CE5000 unit is now operational. You might have to do all the previous steps if you store the unit for a long period of time and lose your data (Windows CE 3.0). For more information about storing the unit, refer to section “STORAGE AND MAINTENANCE”. The loading of files and programs on your device depends of your application and could require the installation of programs on a desktop computer. Please refer to instructions for your application or contact your supervisor. Advanced users may also refer to section “ADVANCED USER INFORMATION” to know how to access CE5000 Technical Guide ACTIVESYNC COMMUNICATION If you are already familiar with Windows CE and ActiveSync and are ready to make your file transfers please refers to section “ActiveSync Communication”, at the end of this manual.

MAN35-A (CMU035-A7)

Page 27

19

ADVANCED BATTERY OPTIONS See How Much Power it Remains K CE.NET Version

FIGURE 5 Under Win CE.NET, click on Start, Settings, Power then the Battery tab, or simply hit the F2 key.

Control Panel,

K CE 3.0 Version NOTE On a regular CE5000, this requires that the main battery be calibrated . See section Power Gauge Calibration

FIGURE 6 Under Win CE 3.0, open Control Panel then Power and select the Status tab.

MAN39-A (CMU035-A7)

Page 28

20

PRESERVING POWER You can extend the battery life by modifying the power delays of the unit, screen and backlit. K CE.NET Version

FIGURE 7 To setup the screen and backlit delays, click on Start, Settings, Control Panel, _Power (underscore Power) then the Power Off tab. The “Turn On backlit after…” menu appears only on unit with a color screen. If you mainly work outside and do not need the backlighted screen, unclick the box to increase the battery life.

FIGURE 8 To setup the power off delay of the unit, click on Start, Setting, Control Panel, Power (no underscore) (or press F2) then the Schemes tab. Select the scheme Battery Power and set-up de suspend delay for the delay that you need. NOTE Selecting Never will keep the unit always running and will reduce the battery life radically.

MAN35-A (CMU035-A7)

Page 29

21 K CE 3.0 Version

FIGURE 9 Win CE 3.0, open Control Panel then Power and select the Power Off tab. The suspend delay is the delay after which the unit will power-off. You need to press the ON/OFF key to restart were you were in the application. The “Turn On backlit after…” menu appears only on unit with a color screen. If you mainly work outside and do not need the backlighted screen, unclick the box to increase the battery life.

Battery Power Management NOTE On a regular CE5000, this requires that the main battery be calibrated .

All CE5000X unit are delivered with a calibrated main battery. This allows you to set-up the device to give you a Low Battery Warning at the level that you will define and will match with your application. On a regular CE5000, this requires that the main battery be calibrated . See section Power Gauge Calibration

See section Power Gauge Calibration

FIGURE 10 FIGURE 10 shows that the default power properties are set to: Low level = 16% Very Low level = 5% This setting means that the Battery Status Indicator will start flashing red when it remains 16% of the complete charge on the main battery. MAN39-A (CMU035-A7)

Page 30

22 You will see the Main Battery field becoming highlighted Low under the Battery or Status tab (FIGURE 5 and FIGURE 6). It will stay highlighted as long as the battery level is between 6 and 16. At 5%, the Battery Status Indicator monitor will still continue to flash and a pop-up window will be displayed telling you that your main battery is very low on power. Messages will be displayed every four (4) minutes approximately. The Main battery field is highlighting Very Low (FIGURE 5 and FIGURE 6). It will stay highlighted as long as the battery level is lower or equal to 5. See section “Low Battery Message” for description of the different messages appearing when going out of battery power You can change these settings to match them to your own need when your battery is going down. For more information about the Battery Power Management on a Microflex CE5000 unit call the Technical Support or go to DAP Technical Web site. NOTE On a CE5000X, calibration will always stay valid but if the delay between two calibrations is to long, displayed information will be less accurate. On a regular CE5000, calibration will stay valid • as long as the main battery is not removed for more than 2 minutes • as long as the main battery is not deeply discharged • for about 30 charge cycles K CE.NET Version To run the Power Properties under CE.NET, click on Start, Setting, Control Panel, _Power (underscore Power) then the Warning tab. K CE 3.0 Version To run the Power Properties under Windows CE 3.0, open Control Panel then Power and select the Warning tab.

Low Battery messages on Main Battery After several hours of usage, the main battery will become low. Two different Low Battery messages will tell you that the main battery needs to be recharged (FIGURE 11and FIGURE 12).

Main Battery Very Low The Main Battery Very Low appears when there is still some power to continue to work. The level at which it appears is adjustable. See previous section “Battery Power Management” Press ESC or tap the X to clear the message. FIGURE 11