The text of a manual · part 5 of 10
TurboWedge Installation and Operations Manual, pages 41 to 50
Pages 41 to 50 of 97
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Compsee Turbo-Wedge
Page 41
•
Stop Bits (RS 232 Input or Output) Program Stop Bits for serial transmission compatibility with the external device connected to the RS 232 Input Port or to the host system if data output is RS 232 Single or Dual Port. If Stop Bit compatibility is not achieved, a series of beeps will be emitted . Stop Bits can be set to either one or two.
•
Dual/Single RS 232 Flow Control (RS232 Dual or Single Port Output) This menu selection is used to configure the flow control for data communication between the unit and its host. The menu choices for Protocol include: NONE - Often referred to as “Ready Mode”. When enabled, data input to the unit will be immediately transmitted. XON / XOFF - When enabled, the command "DC1" from the host to the terminal will initiate communication; the command "DC3" will stop data transmissions. RTS / CTS - When enabled, the RTS / CTS signal lines will control the transmission of data between the host and the terminal.
•
RS 232 Input Protocol (RS 232 Input) If multiple data records are being sent through the unit (Port 2) to the screen from an external portable reader/computer, a Data Transfer Protocol must be set. If a Data Transfer Protocol is not set, the unit will only receive data on a record-to-record basis. A detailed explanation of each Protocol can be found in Appendix F. Through programming you can change the Protocol to one of the following: RECORD BURST Xmodem CRC
= A = C = E
SOLICIT / XON = B ACK/NAK = D
VIII. BAR CODE SELECTIONS Menu Pages - Code Selection Industrial & Retail - Pages H & I These menu pages are used to enable or disable the various bar code symbologies that the unit is able to decode. They are also used to set the different variables within each code symbology. Upon DEFAULT, the unit is able to auto-discriminate between all codes. The DEFAULT variables for each code are indicated by an asterisk on the menu. To change any of the variables, you must: 1) 2) 3) 4) 5)
Enter Industrial/Retail Code Selections Scan the symbology you wish to change Scan the Alpha for the variable you wish to change Scan the selection within the variable. Either select another variable, select another symbology or Exit Code Selections.
Compsee, Inc. TurboWedge-1199
41
Page 42
•
Codabar Variables Selections ENABLE ON or OFF MINIMUM LENGTH 00 -> 64 MAXIMUM LENGTH 00 -> 64 START/STOP XMIT ON or OFF CONCATENATE ON or OFF OFF
Code 3 of 9 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH START/STOP XMIT FULL ASCII CHECK DIGIT CHECK DIGIT XMIT APPEND •
Interleaved 2 of 5 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH 6 and 14 ONLY CHECK DIGIT CHECK DIGIT XMIT
Default ON 00 64 OFF
Selections ON or OFF 00 -> 64 00 -> 64 ON or OFF ON or OFF ON or OFF ON or OFF ON or OFF
Default ON 00 64 OFF ON OFF OFF OFF
Selections ON or OFF 00 -> 64 00 -> 64 ON or OFF ON or OFF ON or OFF
Default ON 04 64 OFF OFF OFF
NOTE: Interleaved 2 of 5 symbology requires that the code read be an even number of digits. •
•
•
Industrial 2 of 5 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH
Selections ON or OFF 00 -> 64 00 -> 64
Default ON 00 64
Code 11 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH ONE CHECK DIGIT TWO CHECK DIGITS
Selections ON or OFF 00 -> 64 00 -> 64 ON ON
Default ON 04 64
Code 93 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH
Selections ON or OFF 00 -> 64 00 -> 64
Default ON 00 64
Compsee, Inc. TurboWedge-1199
ON
42
Page 43
•
•
•
•
Code 128 Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH
Selections ON or OFF 00 -> 64 00 -> 64
Default ON 00 64
Plessey Variables ENABLE MINIMUM LENGTH MAXIMUM LENGTH
Selections ON or OFF 00 -> 64 00 -> 64
Default OFF 04 64
UPC Variables Selections UPC A ON or OFF UPC E ON or OFF 2 DIGIT SUPPLEMENT ON or OFF 5 DIGIT SUPPLEMENT ON or OFF CHECK DIGIT XMIT ON or OFF NUMBER SYS XMIT ON or OFF ZERO SUPPRESS ON or OFF ON
Default ON ON ON ON ON ON
EAN Variables Selections EAN.JAN 8 ON or OFF EAN/JAN 13 ON or OFF 2 DIGIT SUPPLEMENT ON or OFF 5 DIGIT SUPPLEMENT ON or OFF CHECK DIGIT XMIT ON or OFF NUMBER SYS XMIT ON or OFF ZERO SUPPRESS ON or OFF ON
Default ON ON ON ON ON ON
Compsee, Inc. TurboWedge-1199
43
Page 44
IX. EDIT PROGRAMMING CUSTOMER APPLICATIONS PROGRAMMABLE EDIT (CAPE) It is strongly advised that Section 9 be read in its entirety and that a Worksheet be filled out BEFORE you attempt to program any of the CAPE features. The Customer Applications Programmable Edit, referred to as CAPE, is a means by which the user can qualify the raw data record passing through the unit and then define the output format of the data record. The menu programmable features allow the user the following flexibility. •
DATA QUALIFICATION: 1) Specify which port the data record can be received from. Scanner Auxiliary RS 232 Magnetic Stripe 2) Specify which symbology the data record must be represented by. Code 3 of 9 Code 11 Codabar Code 93 I 2 of 5 Plessey 2 of 5 UPC Code 128 EAN All = Any symbology, RS 232 or Mag Stripe 3) Specify the length of the data record. Actual length Variable Length
4) Specify by position in the data record a match to a specific ASCII character. Example: Position 3 of the record must be a "T" and position 5 of the record must be a "7". Qualification Example: A 6 digit Code 3 of 9 bar code with a "5" as the second digit. Qualify = Scanner Port Code 3 of 9 Six digits "5" = second position Only a record passing all four qualifications will pass the edit.
Compsee, Inc. TurboWedge-1199
44
Page 45
•
OUTPUT FORMAT OPTIONS 1) Add data and/or Function Codes to the record Preambles Postambles Insert Within Output Record 2) Delete data from the record. Examples: Do not output field identifiers For Mag Stripe input, only output the Account Number and Expiration Date. 3) Rearrange data from the input record to match the output format. 4) Repeat data found in the input record. Output the same data more than once. 5) Define two output formats for one input record. The second of the two output formats is activated by reading a "Switch Label". Output Format Example: 1) Delete and Add Input = Output =
123T456 123<TAB>456<ENTER>
2) Add, Delete and Rearrange Input = ;5928394920033=92059032490834? Output= 9999<TAB>5928394920033<ENTER>0592<ENTER>
Compsee, Inc. TurboWedge-1199
45
Page 46
EDIT WORKSHEET DATA INPUT: _____________________________________ DATA OUTPUT:___________________________________ EDIT NUMBER: _____ OF _____ Secondary Switch: ____ Deactivate Switch: ____ Secondary Output Record:____ PORT = ________________ SYMBOLOGY = ____________
CODE ____________ CODE ____________
INPUT RECORD LENGTH ______________________ NUMBER OF INPUT FIELDS ____________________ #
LENGTH
FUNCTION CODE
MATCH
NUMBER OF ADDITIONAL FIELDS: _____________ #
LENGTH
DATA (Minimum of 15)
OUTPUT SEQUENCE: ____ ____ ____ ____ ___
Compsee, Inc. TurboWedge-1199
46
Page 47
PROGRAMMING EXAMPLE # 1 Use of Match Code & Added Function Codes INPUT RECORD: N1234567 OUTPUT RECORD: 1234<Field Forward>567<Enter> ENTER EDIT PROGRAMMING Edit Number 01 Port 1 (Scanner) Symbology B (3 of 9) Input Length 08 # of Fields 03 Field 1 Length 01 (N) Function. Code 4E (N = Hex 4E) Match Code ON (Field = N) Field 2 Input Field Length 04 (1234) Function Code 0B (Tab) Field 3 Input Field Length 03 (567) Function Code 0D (Enter) Added Fields 00 Added Field Length Ignore Added Field Data Ignore Output Sequence 02, 03 EXIT EDIT PROGRAMMING
- NO CHANGE IN OUTPUT - MUST BEGIN WITH "N" FOR VALID EDIT
Compsee, Inc. TurboWedge-1199
47
Page 48
PROGRAMMING EXAMPLE # 2 Added Data & Rearrange Fields INPUT RECORD: 1234567890 OUTPUT RECORD: 67890-BAR<ENTER>12345-CODE<ENTER> ENTER EDIT PROGRAMMING Edit Number Port: Symbology Input Record Length Fields In Input Record Field 1 Input Field Length Function Code Field 2 Input Field Length Function Code Added Fields Field 3 Added Field Length Added Field Data Field 4: Added Field Length Added Field Data Output Sequence EXIT EDIT PROGRAMMING
01 1 (Scanner) B (CODE 3 OF 9) 10 02 05 (12345) 00 (Null) 05 (67890) 00 (Null) 02 05 2D, 42, 41, 52, 0D (- B A R) 06 2D, 43, 4F, 44, 45, 0D (- C O D E) 02, 03, 01, 04
- NO CHANGE IN OUTPUT - MUST BE 10 DIGITS FOR EDIT
Compsee, Inc. TurboWedge-1199
48
Page 49
•
METHOD OF PROGRAMMING The CAPE features are programmed by first filling out the WorkSheet that is contained in the manual and then programming in the parameters via the Edit Parameter Menu. The programming sequence involves steps in which you qualify the data as to what it is and how it was generated, then specify how it is to be divided into fields. After the input record definition, additional fields are defined and then the output sequence of all the fields.
•
TERMINOLOGY INPUT RECORD = FIELD = ADDITIONAL FIELD = OUTPUT RECORD = FUNCTION CODES =
•
Raw data received from a port. A division of the Input Record. Data not present in the Input Record, but to be present in the Output Record. Data to be sent to the terminal. Keyboard depressions that cause a function to occur rather then data. Example: Data equals key entry of a, 1, T, B, 7, +, #, etc., where a function code equals key entry of TAB, CTRL, ENTER, F1, Up Arrow, etc.
PORTS SCANNER PORT = code scanning input
Input from the bar code port on the wedge. Accepts a digital signal from bar devices.
AUXILIARY PORT = auxiliary port on the
RS 232 input from a device (scale, portable terminal, etc.) attached to the wedge. Accepts ASCII data from RS 232 output devices attached to it.
MAGNETIC PORT =
•
Input from a Magnetic Stripe Reader attached to the auxiliary port on the wedge.
SEQUENCE OF PROGRAMMING
1) Scan ENTER EDIT PROGRAMMING 2) Specify Edit Number. a) A "01" Edit must always be specified. b) The "01" edit must always be the first edit. c) Maximum number of edits that can be defined are 99, or until all of the memory allocated for edit programming has been used.(Model 1 = 1024kb, Model 2 = 2048kb) 3) DATA QUALIFIER: Specify Input Port The first data qualifier is the port from which the input record will be received. Options include; Scanner, Auxiliary, Magnetic or ALL. If you do not care where the data was entered from, specify ALL. 4) DATA QUALIFIER: Specify Symbology The Second data qualifier is the symbology that the record must be represented by. If you know that the data can only be one specific code symbology, specify that symbology. If it does not matter what symbology the data is represented by, then indicate "ALL".
Compsee, Inc. TurboWedge-1199
49
Page 50
5) DATA QUALIFIER: Specify Input Record Length The third data qualifier is the length of the input record (number of characters). If length is not a qualifier, specify "00". The variable field length will be determined by the end of the input record or by the specifying a match code as the following field. The variable field will contain the data up to, but not including the match code field. 6) Specify Fields in the Input Record The Input Record can be divided into multiple fields. Specify the total number of fields that will be defined. 7) Specify Input Field Length Starting with the left most (high order) position of the input record, indicate the length of the field. If the field is to be matched against a specific code, it should be defined as a Match Code. To do so, define a length of "01", specify in the Function Code Parameter the Hex Code to match and then scan "ON" to specify it as a Match Code. 8) Specify Function Code A single (1) Function Code must be specified to follow a field. A Function Code may be any of the ASCII characters. Example, a Function Code may be the character "A" or the digit "6" or a keyboard function such as "Field Forward". If no Function Code is desired, specify "00". All Function Codes are defined using Key Codes. Reference Appendix C, Key Code Chart for a listing. NOTE: MATCH CODE If the field being defined is to be used as a Match Code Qualifier, the Function Code definition becomes the Key Code for the character to be matched. 9) OPTIONAL ENTRY: Specify Match Code Any or all characters within an Input Record may be matched individually against a predetermined character. If matching is NOT desired IGNORE this entry. If matching is desired a) Input Field Length = 01 b) Function Code = Hex Code to Match to c) Match Code = ON REPEAT ITEMS 7 - 9 UNTIL ALL FIELDS FOR THE INPUT RECORD HAVE BEEN DEFINED. 10) Specify Number of Additional Fields Fields may be added to the Output Record as desired. Indicate how many fields you wish to add. If NO Added Fields are desired scan in 00 and IGNORE 11 & 12. 11) Specify Additional Field Length Specify the length (number of digits) that will be added in this field definition. Ignore this entry if there are NO Additional Fields.
Compsee, Inc. TurboWedge-1199
50